Two operators at a control-room desk with a row of monitors, a laptop and keyboards

OT/ICS security

Rockwell FactoryTalk vulnerabilities: View SE and ME, Linx and RSLinx Classic, AssetCentre, Services Platform and Studio 5000, fixed versions and hardening

Last updated:

Rockwell Automation's FactoryTalk software (View SE and ME, Linx and RSLinx Classic, AssetCentre, Services Platform) and Studio 5000 Logix Designer had no CVE in CISA's KEV catalog as of 2026-11-28, but CISA's advisories show five recurring families: unauthenticated CIP packet handling in the communication software, unauthenticated .NET remoting in AssetCentre, authentication and token flaws in the FactoryTalk Services Platform, weak project folder permissions on HMI nodes, and malicious project files on engineering workstations.

Fixes arrive as corrected releases, individual patches and monthly patch roll-ups.

The rest of this guide places each product in a plant network, names the three ports that Rockwell and CISA give, walks through 30 CVE ids by product with the corrected versions and mitigations from CISA's ICS advisories, which carry Rockwell's own recommendations, and ends with versioning, hardening, monitoring and a worked example. Scores name their scorer, because CISA's advisory score and NVD's Primary score for the same CVE often differ.

This guide covers the software layer. The controllers themselves, ControlLogix, CompactLogix and GuardLogix with their communication modules, are covered in the separate Rockwell Logix controller vulnerabilities guide, and this guide does not repeat its CVE ids.

Key takeaways

  • This guide covers the software layer.
  • CISA's Rockwell advisories list the vendor as headquartered in the United States with products deployed worldwide, and the 2026 RSLinx Classic advisory ICSA-26-244-01 names the critical manufacturing sector.
  • Three port numbers appear in the advisories.
  • FactoryTalk View SE advisories move from a network-reachable project file flaw in 2020 to authentication and folder permission flaws from 2023 on.

What is FactoryTalk, and where does it sit above the Logix controllers?

CISA's Rockwell advisories list the vendor as headquartered in the United States with products deployed worldwide, and the 2026 RSLinx Classic advisory ICSA-26-244-01 names the critical manufacturing sector. FactoryTalk is the brand for Rockwell's plant software, and the products in this guide fall into five roles:

Product What it does Typical place in the network
FactoryTalk View Site Edition (SE) Distributed HMI: HMI servers hold the projects, SE clients show the screens, View Studio edits them Supervisory servers and operator stations
FactoryTalk View Machine Edition (ME) Machine-level HMI runtime; CISA's advisories describe it running on PanelView Plus terminals and on industrial PCs Operator panels at the machine
FactoryTalk Linx and RSLinx Classic Communication software that connects HMIs, historians, OPC clients and engineering tools to controllers over CIP On HMI servers, engineering workstations and PanelView Plus terminals
FactoryTalk AssetCentre Central asset management: project archive, change logs and comparison of controller programs Site operations level, with agents on engineering machines
FactoryTalk Services Platform (FTSP) Shared services under the FactoryTalk products, including the FactoryTalk Directory and FactoryTalk Security Every node that runs FactoryTalk software
Studio 5000 Logix Designer Engineering software that programs Logix controllers Engineering workstations

The table matters for patching: FTSP sits under View SE, Linx and AssetCentre, and CISA's ICSA-20-163-02 lists FactoryTalk Linx code inside Studio 5000 Launcher, Logix Designer, AssetCentre, Connected Components Workbench and ControlFLASH. A Linx flaw can therefore sit on a workstation that nobody lists as a communication server. For the zoning behind the table, see the Purdue model guide.

Which ports and services do Rockwell and CISA name?

Three port numbers appear in the advisories. Most newer advisories describe local, file-based or token flaws and name no port.

Path Product What the sources say
Port 44818 (CIP) RSLinx Classic Malformed CIP packets crash the service or overflow a buffer (CVE-2018-14829, CVE-2019-6553, CVE-2026-9621). Rockwell, quoted in ICSA-19-064-01: the port is needed only for unsolicited messages and closes when "Accept UDP Messages on Ethernet Port" is cleared, the default from RSLinx Classic 4.10
Port 4444/UDP, LogReceiver.exe RSLinx Enterprise CPR9 to CPR9-SR6 Crafted datagrams crash the service (CVE-2013-2805, ICSA-13-095-02A)
Port 8091 FactoryTalk View SE before V15.0 "Restrict access to Port 8091 at the network or workstation" until the upgrade or patch (CVE-2025-24481, ICSA-25-028-04)
CIP to the PanelView Plus FactoryTalk View ME and FactoryTalk Linx on the terminal Crafted packets run code or leak memory (CVE-2023-2071, ICSA-23-264-06; CVE-2023-29464 in ICSA-23-290-02)
.NET remoting endpoints FactoryTalk AssetCentre v10.00 and earlier Unauthenticated deserialization, SQL and command injection (ICSA-21-091-01)

CIP itself, including the Forward Open and Forward Close services named in the RSLinx Classic advisories, is explained in the EtherNet/IP and CIP protocol security guide. The BOD 23-02 guide on internet-exposed management interfaces shows how to confirm that none of these services answers from outside.

Which FactoryTalk View SE and ME vulnerabilities did CISA publish?

FactoryTalk View SE advisories move from a network-reachable project file flaw in 2020 to authentication and folder permission flaws from 2023 on. Six of them:

CVE Weakness CISA score NVD Primary Fix or mitigation named
CVE-2020-12029 Filenames in a project directory not validated; a crafted file may run code on a remote endpoint (all versions) v3 9.0 v3.1 7.8 Patch 1126289, after the CPR9 SRx patch roll-up dated 6 April 2020 or later (ICSA-20-170-05)
CVE-2023-46289 Insufficient input validation takes the product offline until restart (V11.0) v3 7.5 v3.1 7.5 Patches for V11.0, V12.0 and V13.0 (ICSA-23-299-05)
CVE-2024-37367 Authentication flaw lets an outside attacker view an HMI project (v12.0) v3 8.6 v3.1 7.5 Corrected in V14.0 and later; IPsec segmentation until then (ICSA-24-165-16)
CVE-2024-37369 Incorrect permissions let low-privilege users edit scripts and bypass access control lists (v12.0) v3 7.8 v3.1 8.8 Corrected in V14.0 and later; use the Secure Install option of FTSP (ICSA-24-165-17)
CVE-2024-7513 Any user can edit or replace project files that run with elevated permissions (13.0) v3 8.8 v3.1 8.8 Remove the INTERACTIVE group from the HMI projects folder and grant named users only (ICSA-24-226-06, Rockwell SD 1688)
CVE-2025-24481 Incorrect permission assignment gives unauthenticated access to configuration files (before 15.0) v3 7.3 none V15.0 or patch Answer ID 1152306; restrict port 8091; protect physical access (ICSA-25-028-04)

ICSA-24-226-06 gives the default folder: HMI server projects are saved in C:\Users\Public\Documents\RSView Enterprise\SE\HMI projects. Users given read-only permission there can still test-run and run the SE client. ICSA-25-028-04 lists a second CVE, a DLL loading flaw fixed by V15.0 or patch Answer ID 1152304, and asks owners to make sure the FactoryTalk View SE installation path comes first in the PATH variable.

FactoryTalk View ME advisories mix terminal-side network flaws with the same folder permission pattern on the Windows editor:

CVE Weakness CISA score NVD Primary Fix or mitigation named
CVE-2023-2071 Improper input validation on the PanelView Plus: crafted packets through a CIP class run code without authentication (v13.0, 12.0 and earlier) v3 9.8 v3.1 9.8 The v12.0 and v13.0 security patches (ICSA-23-264-06)
CVE-2024-37365 Projects saved in a public directory; a local user can change a macro to run code (v14.0 and earlier with default folder privileges) v3 7.3 v3.1 7.8 Corrected in V15.0; remove the INTERACTIVE group from the HMI projects folder (ICSA-24-317-03)
CVE-2025-9064 Path traversal: unauthenticated attackers on the same network delete files on the panel operating system v3 7.5 v3.1 9.1 PanelView Plus 7 Performance Series B V14.103 firmware package, or patch BF31001 for View ME V15.00 on ASEM 6300 industrial PCs (ICSA-25-289-01)

ICSA-25-289-01 lists a second flaw, an authentication bypass in the FactoryTalk View ME Web Browser ActiveX control, fixed by the same V14.103 firmware package. The path traversal pattern behind CVE-2025-9064 is covered in the path traversal fix guide.

What are the FactoryTalk Linx and RSLinx Classic vulnerabilities?

The communication software has the largest share of unauthenticated network flaws, because it parses CIP traffic from controllers and clients. Nine CVE ids:

CVE Weakness CISA score NVD Primary Fix or mitigation named
CVE-2020-27251 Heap overflow from malicious port ranges, remote code execution without authentication (FactoryTalk Linx 6.11 and earlier) v3 9.8 v3.1 9.8 Patch Answer ID 1126433 for 6.10 and 6.11, or move to 6.20 (ICSA-20-329-01)
CVE-2020-27253 Flaw in the ingress/egress checks: a crafted packet causes denial of service v3 8.6 v3.1 7.5 Same
CVE-2020-11999 Exposed API call processes files without sanitation, so a chosen filename can run code (Linx 6.00 to 6.11 and the products bundling it) v3 9.6 v3.1 8.1 FactoryTalk Linx patches RAID 1124820 and 1126433, with the CPR9 SRx patch roll-up (ICSA-20-163-02)
CVE-2025-7972 Linx Network Browser: setting process.env.NODE_ENV to 'development' disables FTSP token validation, allowing drivers to be created, changed and deleted (before 6.50) v3 9.0 v3.1 9.1 Update to 6.50 (ICSA-25-226-24)
CVE-2018-14829 Malformed CIP packet to port 44818 crashes RSLinx Classic or overflows a stack buffer (4.00.01 and earlier) v3 10.0 v3.0 9.8 New version in KB 1075712; disable port 44818 if unused (ICSA-18-263-02)
CVE-2019-6553 Forward Open request data copied into a fixed-size buffer, stack overflow (RSLinx Classic 4.10.00 and earlier) v3 10.0 v3.1 9.8 Patches for v3.60 to v4.10 in Article ID 1084828; disable port 44818 if unsolicited messages are not used (ICSA-19-064-01)
CVE-2020-10642 A local user modifies a registry key so code runs with system privileges when RSLinx Classic opens (4.11.00 and earlier) v3 8.8 v3.1 7.8 Patch 1091155 for versions 3.60 to 4.11, or the latest RSLinx Classic (ICSA-20-100-01)
CVE-2026-9621 Malformed CIP packet causes an integer overflow and crashes the RSLinx Classic service (4.50 and earlier) v3 8.6 none Corrected in RSLinx Classic 4.60 (ICSA-26-244-01)
CVE-2013-2805 Oversized "Record Data Size" in a datagram to LogReceiver.exe on port 4444/UDP crashes the service (RSLinx Enterprise CPR9 to CPR9-SR6) v2 7.8 v3.0 7.5 CPR9-SR5 or newer, then the matching patch (ICSA-13-095-02A)

ICSA-26-244-01 groups four CIP denial-of-service CVEs in RSLinx Classic 4.50 and earlier, including a Forward Close flaw, all corrected in 4.60. For later FactoryTalk Linx releases, ICSA-25-289-02 describes two installer repair flaws in Linx 6.40 and earlier that give a SYSTEM command prompt to an authenticated Windows user; Rockwell asks owners to apply the Microsoft MSI patch and move to 6.50 or later. For the code side of the memory corruption family, see the memory corruption fix guide.

Which FactoryTalk AssetCentre flaws are the most serious?

AssetCentre's 2021 advisory is the most severe in this guide: ICSA-21-091-01 lists nine CVE ids in v10.00 and earlier, every one scored CVSS v3 10.0 by CISA, all reachable without authentication. Three show the pattern, with the 2025 credential flaw:

CVE Weakness CISA score NVD Primary Fix or mitigation named
CVE-2021-27462 Deserialization in the AosService.rem service runs commands without authentication v3 10.0 v3.1 9.8 AssetCentre v11 or later; IPsec per QA46277, tested on v9 to v11 (ICSA-21-091-01)
CVE-2021-27472 SQL injection in the RunSearch function of the SearchService service v3 10.0 v3.1 9.8 Same
CVE-2021-27476 OS command injection in the SaveConfigFile function of the RACompare Service v3 10.0 v3.1 9.8 Same
CVE-2025-0477 Weak encryption lets a user extract other users' passwords (before V15.00.001) v3 9.8 v3.1 9.8 V15.00.001 or later; control database access by non-essential users (ICSA-25-030-05)

CISA's ICSA-21-091-01 says one of the nine, CVE-2021-27460, may give "full access to the FactoryTalk AssetCentre main server and all agent machines," so treat the AssetCentre server as a high-value system. ICSA-25-030-05 adds two credential storage flaws, fixed by V15.00.001, by the January 2025 monthly patch roll-up, and by patch BF31148 for the extractor packages. The injection families have their own command injection fix guide.

What are the FactoryTalk Services Platform vulnerabilities?

FTSP holds FactoryTalk Security and the FactoryTalk Directory, so its flaws are about who can log in and with what rights:

CVE Weakness CISA score NVD Primary Fix or mitigation named
CVE-2020-14516 Faulty SHA-256 password hashing lets a remote attacker create users in the administration console (6.10.00 and 6.11.00) v3 10.0 v3.1 10.0 The new FTSP release Rockwell published (ICSA-21-054-01)
CVE-2020-12033 Redundancy host service RdcyHost.exe does not validate identifiers, so an adjacent attacker can run remote COM components with elevated privileges (all versions) v3 7.5 v3.1 8.8 Secure communication per Rockwell KB 109056; KB 25612 shows whether FTSP is installed (ICSA-20-170-04)
CVE-2021-32960 Security policies based on computer name can be bypassed by a remote, authenticated user (v6.11 and earlier with FactoryTalk Security on) v3 8.5 v3.1 8.8 FTSP v6.20 or later; avoid remote desktop where possible and log RDP sessions (ICSA-21-161-01)
CVE-2024-21917 Service token not digitally bound to the directory, so it can be reused on another FTSP directory (before v6.4) v3 9.8 v3.1 9.1 v6.40 or later; until then, require publisher verification for executables calling the FactoryTalk Services APIs (ICSA-24-030-06)
CVE-2026-10714 JWT signature validation can be bypassed in Okta Web Authentication by setting the algorithm to "none" (FTSP 6.60) v3 7.8 none Patch RAID 1158263 or the February 2026 Patch Roll-up or later (ICSA-26-202-07)

The CVE-2020-14516 advisory page has the record text and affected versions. FTSP flaws reach further than FTSP itself: CISA's ICSA-21-054-01 warns that new users created through CVE-2020-14516 could modify or delete configuration and application data in other FactoryTalk software connected to the platform.

What about Studio 5000 Logix Designer?

The Logix Designer advisories below concern the engineering workstation, not the controller. Controller-side CVEs, including the authentication and key flaws, are in the Logix controller guide.

CVE Weakness CISA score NVD Primary Fix or mitigation named
CVE-2022-1159 An attacker with administrator access on the workstation can inject controller code a user cannot see (all versions) v3 7.7 v3.1 7.2 No direct fix; detect with the Logix Designer Compare Tool v9 or later, or AssetCentre v12 or later program verification, from an uncompromised workstation, with Studio 5000 v34 or later (ICSA-22-090-07)
CVE-2025-7971 Unsafe handling of environment variables can crash Logix Designer or run code (36.00.02 up to 37.00.02) v3 7.5 none Update to 37.00.02 or later (ICSA-25-226-29)
CVE-2026-9108 Path traversal through file names inside an ACD project file during project opening (V32 to V36 lines) v3 6.7 v3.1 7.5 V37.00, 36.01, 35.02, 34.04, 33.04 or 32.05 (ICSA-26-202-10)

ICSA-26-202-10 lists two more flaws in the same advisory, an authorization flaw in the External Tools configuration file and an unquoted search path in the same feature, each with its own set of corrected versions per release line. Read the advisory per line: V34.03 fixes two of the three, V34.04 all three.

Why do NVD and CISA scores differ for these CVEs?

They score different assumptions, and the gap runs both ways. NVD's Primary CVSS v3.1 score is 9.1 for the View ME path traversal CVE-2025-9064, where CISA says 7.5, and 8.8 for the View SE permissions flaw CVE-2024-37369 and the FTSP redundancy flaw CVE-2020-12033, where CISA says 7.8 and 7.5. NVD is lower for the View SE project file flaw CVE-2020-12029 (7.8 against CISA's 9.0), the Linx file API flaw CVE-2020-11999 (8.1 against 9.6) and the View SE authentication flaw CVE-2024-37367 (7.5 against 8.6). The 2021 AssetCentre CVEs are 9.8 at NVD and 10.0 at CISA. As of 2026-11-28, four CVE ids in the tables (CVE-2025-24481, CVE-2025-7971, CVE-2026-9621 and CVE-2026-10714) had no NVD Primary score; their CVE.org records carry Rockwell's CVSS v4.0 scores, such as 9.2 in the CVE.org record for CVE-2026-9621, so name the scorer whenever you quote a number.

How does Rockwell version and patch FactoryTalk software?

Rockwell fixes show up in four forms in the CISA advisories, often side by side:

  • Corrected releases. "Corrected in" a version number: FactoryTalk View SE V14.0 and V15.0, View ME V15.0, FactoryTalk Linx 6.20 and 6.50, RSLinx Classic 4.60, AssetCentre v11 and V15.00.001, FTSP v6.20 and v6.40, Logix Designer 37.00.02.
  • Individual patches with an Answer or RAID id. Patch 1126289 for View SE, Answer ID 1126433 for Linx, patch 1091155 for RSLinx Classic, RAID 1158263 for FTSP 6.60. Newer advisories use BF ids, such as BF31001 for View ME and BF31148 for AssetCentre.
  • Patch roll-ups. The CPR9 SRx roll-up was a prerequisite for the 2020 View SE and Linx patches; the monthly roll-ups of January 2025 and February 2026 are the fix for AssetCentre and FTSP flaws.
  • Configuration-only mitigations. Folder permissions for View SE and ME projects, disabling port 44818 in RSLinx Classic, IPsec for AssetCentre and View SE, and detection rather than a fix for CVE-2022-1159.

Older releases fall out of the fixes. CISA's 2013 advisory asked FTSP and RSLinx Enterprise owners on CPR9 to CPR9-SR4 to upgrade to CPR9-SR5 or newer before patching, and 2024 to 2026 advisories offer patches for named release lines only. Record the FactoryTalk release and the installed patches separately for each node: "FactoryTalk View SE 13.0" alone does not tell you whether the CVE-2023-46289 patch is in.

How do KEV and EPSS rank these CVEs?

As of 2026-11-28, CISA's KEV catalog (version 2026.11.27, 1,808 entries) has one Rockwell entry, CVE-2021-22681, the Logix Designer and Logix controller key flaw added on 2026-03-05, which the Logix guide covers. None of the 30 CVE ids in this guide's tables is listed. FIRST EPSS scores dated 2026-11-27 put the old network-reachable flaws on top:

CVE Product EPSS (2026-11-27) Percentile
CVE-2019-6553 RSLinx Classic 0.663 0.995
CVE-2020-12029 FactoryTalk View SE 0.470 0.991
CVE-2018-14829 RSLinx Classic 0.161 0.975
CVE-2020-27251 FactoryTalk Linx 0.068 0.948
CVE-2021-27472 FactoryTalk AssetCentre 0.057 0.937
CVE-2020-14516 FactoryTalk Services Platform 0.042 0.918

Every other CVE id here scored 0.041 or below, and every one from 2023 onward 0.026 or below. NVD's record for CVE-2019-6553 shows the NVD Primary score of 9.8 behind the top entry. Sites still running RSLinx Classic before 4.10 with port 44818 open, unpatched View SE from before 2020 or AssetCentre v10 are the ones these numbers point at. The KEV and EPSS prioritization guide explains how to combine the two signals.

How do you harden FactoryTalk systems?

Work from Rockwell's and CISA's own mitigations:

  1. Move to corrected releases and current roll-ups: RSLinx Classic 4.60, FactoryTalk Linx 6.50, View SE V15.0, AssetCentre V15.00.001, FTSP 6.40 or the 6.60 roll-up, Logix Designer at the corrected version for each line.
  2. Close port 44818 in RSLinx Classicwhere unsolicited messages are not used, as Rockwell describes in ICSA-19-064-01, and restrict port 8091 on View SE nodes until V15.0.
  3. Lock down the HMI projects foldersRemove the INTERACTIVE group and grant named users only, for View SE (ICSA-24-226-06) and View ME (ICSA-24-317-03).
  4. Use IPsec and HTTPSbetween FactoryTalk nodes, as Rockwell recommends for View SE (KB 109056 and 1126943) and AssetCentre (QA46277), and install FTSP with the Secure Install option.
  5. Protect project files and engineering stationsOpen ACD and other project files only from trusted sources, and compare controller programs against known-good copies from an uncompromised workstation, as ICSA-22-090-07 advises.
  6. Run software as a user, not an administrator, use AppLocker or similar allowlisting, and grant service accounts only the database rights they need, as ICSA-20-329-01 lists.
  7. Firewall the control networkCISA asks owners to keep control system devices off the internet, put control networks behind firewalls isolated from business networks, and use VPNs for remote access, keeping the VPN itself updated.

CISA's advisories point to its defense-in-depth paper and ICS recommended practices; the NIST SP 800-82 guide covers the same ground. Plan release and roll-up changes through a change process such as the one in the IEC 62443-2-3 patch management guide. For a comparison with other HMI vendors, the AVEVA InTouch and System Platform guide and the GE Proficy and CIMPLICITY guide use the same structure.

How do you check which FactoryTalk versions a site runs?

The advisories tie fixes to release, patch and roll-up, so collect all three for each node:

  1. List every FactoryTalk product per node, including Linx and FTSP installed as dependencies of View, AssetCentre, Studio 5000, Connected Components Workbench and ControlFLASH.
  2. Record the release in Rockwell's own format: View SE 13.0, Linx 6.40, RSLinx Classic 4.50.00, AssetCentre 15.00.001, Logix Designer 36.00.02.
  3. Record installed patches and the latest roll-up dateRockwell's KB 25612, cited in ICSA-20-170-04, shows how to tell whether FTSP is installed.
  4. Record PanelView Plus firmware packages separatelyfrom the View ME version used to build the application.
  5. Note which services are on: port 44818 in RSLinx Classic, the AssetCentre server and agents, FTSP redundancy and web authentication.

How do you monitor FactoryTalk networks?

Start with a baseline of which hosts talk to each HMI server, communication server, AssetCentre server and engineering workstation, and on which ports, then alert on changes:

  • New hosts sending to port 44818 on RSLinx Classic nodes, which fits CVE-2018-14829, CVE-2019-6553 and CVE-2026-9621.
  • Datagrams to port 4444/UDP on RSLinx Enterprise nodes, which fits CVE-2013-2805.
  • Connections to port 8091 on View SE nodes from outside the client list, which fits CVE-2025-24481.
  • New clients reaching the AssetCentre server, which fits the ICSA-21-091-01 remoting flaws.

Flow records show who connected to which port and when, not which CIP service was called or which file was loaded. Map alerts to MITRE ATT&CK for ICS techniques such as exploitation of remote services.

Worked example: what does a review of a packaging plant's FactoryTalk estate find?

Synthetic example, not a real site. A packaging plant runs FactoryTalk View SE 13.0 on two HMI servers, RSLinx Classic 4.11 on the same servers for an OPC link, AssetCentre v10 for program backups, FTSP 6.11 with FactoryTalk Security, PanelView Plus 7 terminals with View ME applications, and Studio 5000 Logix Designer 34.01 on a shared engineering laptop.

Observation Why it matters Action
AssetCentre v10, reachable from the office network Nine unauthenticated CVSS 10.0 flaws from ICSA-21-091-01 are open Upgrade to V15.00.001; restrict clients with IPsec; firewall the server to engineering hosts
RSLinx Classic 4.11 with "Accept UDP Messages on Ethernet Port" on CIP flaws on port 44818, including CVE-2026-9621, are open Upgrade to 4.60; clear the option if unsolicited messages are not used
View SE 13.0 without the 2023 patch, default HMI projects folder CVE-2023-46289 and CVE-2024-7513 are open Move to V15.0; remove the INTERACTIVE group from the projects folder
FTSP 6.11 CVE-2021-32960 and CVE-2024-21917 are open Move to FTSP 6.40 or later; enable publisher verification in the meantime
Logix Designer 34.01 on a laptop that opens project files from integrators CVE-2026-9108 is open Update to 34.04; open ACD files only from trusted sources

Where does passive monitoring fit in a FactoryTalk review?

A passive capture shows who talks to HMI, communication and engineering nodes without logging in to anything. SoftWSP's OT Snapshot reads Zeek and ICSNPP logs from a mirror-port recording and builds a host-by-port inventory at connection level, including hosts using ports 44818, 4444 and 8091, and lists remote-access sessions that cross from outside the private address range. It does not decode FactoryTalk or CIP service content or read software versions from traffic. Component and version identification comes from the asset records and software lists you share, with release and patch level per node. SoftWSP matches the versions found against CVE, CISA KEV and FIRST EPSS data, and an engineer reviews the AI-written summary before it reaches you.

What are the common pitfalls?

  • Recording "FactoryTalk View SE 13.0" without the installed patches or roll-up date, when the fix is a patch.
  • Forgetting that FactoryTalk Linx and FTSP come with Studio 5000, AssetCentre and other tools, not only with View.
  • Patching View ME on the engineering workstation and leaving the PanelView Plus firmware package unchanged.
  • Leaving RSLinx Classic accepting unsolicited messages on port 44818 when no application needs them.
  • Treating the AssetCentre server as a back-office tool when its agents reach every engineering machine.
  • Confusing controller CVEs with software CVEs: the only Rockwell KEV entry is a Logix Designer and controller flaw, covered in the Logix guide.

This guide draws on CISA ICS advisories ICSA-13-095-02A, ICSA-18-263-02, ICSA-19-064-01, ICSA-20-100-01, ICSA-20-163-02, ICSA-20-170-04, ICSA-20-170-05, ICSA-20-329-01, ICSA-21-054-01, ICSA-21-091-01, ICSA-21-161-01, ICSA-22-090-07, ICSA-23-264-06, ICSA-23-290-02, ICSA-23-299-05, ICSA-24-030-06, ICSA-24-165-16, ICSA-24-165-17, ICSA-24-226-06, ICSA-24-317-03, ICSA-25-028-04, ICSA-25-030-05, ICSA-25-226-24, ICSA-25-226-29, ICSA-25-289-01, ICSA-25-289-02, ICSA-26-202-07, ICSA-26-202-10 and ICSA-26-244-01 and their CSAF records, which carry Rockwell Automation's recommendations; NVD and CVE.org records; CISA KEV and FIRST EPSS, all checked as of 2026-11-28.

Put this guide to work

Frequently asked questions

Are any FactoryTalk or RSLinx vulnerabilities in the CISA KEV catalog?

No. As of 2026-11-28, CISA's Known Exploited Vulnerabilities catalog (version 2026.11.27, 1,808 entries) has exactly one Rockwell entry, CVE-2021-22681, the Logix Designer and Logix controller key flaw added on 2026-03-05, and none of the 30 FactoryTalk, RSLinx and Studio 5000 CVE ids in this guide's tables is listed. The highest FIRST EPSS score among them, dated 2026-11-27, belongs to CVE-2019-6553, the RSLinx Classic Forward Open stack overflow, at 0.663. Next come CVE-2020-12029 in FactoryTalk View SE at 0.470 and CVE-2018-14829 in RSLinx Classic at 0.161.

Which ports do Rockwell and CISA name for FactoryTalk software?

Three. RSLinx Classic accepts CIP messages on port 44818; CISA's ICSA-19-064-01 quotes Rockwell that the port is needed only for unsolicited messages and can be closed by clearing 'Accept UDP Messages on Ethernet Port', which is cleared by default from RSLinx Classic 4.10. ICSA-13-095-02A names port 4444/UDP for the RSLinx Enterprise LogReceiver service, and ICSA-25-028-04 asks FactoryTalk View SE owners to restrict access to port 8091 until they upgrade to V15.0 or apply the patch.

What is a Rockwell patch roll-up, and is it enough?

A patch roll-up is Rockwell's cumulative bundle of FactoryTalk patches. CISA's advisories show it used in two ways: as a prerequisite, as in ICSA-20-170-05 where the FactoryTalk View SE patches need the CPR9 SRx roll-up dated 6 April 2020 or later first, and as the fix itself, as in ICSA-26-202-07 where the February 2026 Patch Roll-up fixes CVE-2026-10714 in FactoryTalk Services Platform 6.60. A roll-up does not replace a version upgrade when the advisory says the fix is only in a new release, such as FactoryTalk View SE V14.0 for CVE-2024-37367.

Does upgrading FactoryTalk View fix the PanelView Plus terminals too?

Not by itself. Several FactoryTalk View Machine Edition and FactoryTalk Linx flaws run on the PanelView Plus terminal, so the fix is a terminal firmware package or a patch for the runtime. CISA's ICSA-25-289-01 fixes CVE-2025-9064 with the PanelView Plus 7 Performance Series B V14.103 firmware package, or with patch BF31001 for FactoryTalk View ME V15.00 on ASEM 6300 industrial PCs. ICSA-23-264-06 and ICSA-23-290-02 ask owners to install the security patches for their FactoryTalk View ME and Linx versions on the PanelView Plus.

Why do NVD and CISA scores differ for FactoryTalk CVEs?

They score different assumptions. NVD's Primary CVSS v3.1 score for the FactoryTalk View SE project file flaw CVE-2020-12029 is 7.8, where CISA says 9.0; for the View ME path traversal CVE-2025-9064 NVD says 9.1 against CISA's 7.5. As of 2026-11-28, four of the 30 CVE ids in the tables had no NVD Primary score at all, only Rockwell's and CISA's, so name the scorer whenever you report a number.

Sources

  1. CISA ICS Advisory ICSA-26-244-01: Rockwell Automation RSLinx Classic
  2. CISA CSAF: ICSA-20-170-05 Rockwell Automation FactoryTalk View SE
  3. CISA CSAF: ICSA-23-299-05 Rockwell Automation FactoryTalk View Site Edition
  4. CISA CSAF: ICSA-24-165-16 Rockwell Automation FactoryTalk View SE
  5. CISA CSAF: ICSA-24-165-17 Rockwell Automation FactoryTalk View SE
  6. CISA CSAF: ICSA-24-226-06 Rockwell Automation FactoryTalk View Site Edition (Update A)
  7. CISA CSAF: ICSA-25-028-04 Rockwell Automation FactoryTalk View Site Edition
  8. CISA CSAF: ICSA-23-264-06 Rockwell Automation FactoryTalk View Machine Edition
  9. CISA CSAF: ICSA-24-317-03 Rockwell Automation FactoryTalk View ME
  10. CISA CSAF: ICSA-25-289-01 Rockwell Automation FactoryTalk View Machine Edition and PanelView Plus 7
  11. CISA CSAF: ICSA-20-163-02 Rockwell Automation FactoryTalk Linx Software (Update A)
  12. CISA CSAF: ICSA-20-329-01 Rockwell Automation FactoryTalk Linx
  13. CISA CSAF: ICSA-23-290-02 Rockwell Automation FactoryTalk Linx
  14. CISA CSAF: ICSA-25-226-24 Rockwell FactoryTalk Linx
  15. CISA CSAF: ICSA-13-095-02A Rockwell Automation FactoryTalk and RSLinx Vulnerabilities
  16. CISA CSAF: ICSA-18-263-02 Rockwell Automation RSLinx Classic
  17. CISA CSAF: ICSA-19-064-01 Rockwell Automation RSLinx Classic
  18. CISA CSAF: ICSA-20-100-01 Rockwell Automation RSLinx Classic
  19. CISA CSAF: ICSA-26-244-01 Rockwell Automation RSLinx Classic
  20. CISA CSAF: ICSA-21-091-01 Rockwell Automation FactoryTalk AssetCentre
  21. CISA CSAF: ICSA-25-030-05 Rockwell Automation FactoryTalk AssetCentre
  22. CISA CSAF: ICSA-20-170-04 Rockwell Automation FactoryTalk Services Platform
  23. CISA CSAF: ICSA-21-054-01 Rockwell Automation FactoryTalk Services Platform
  24. CISA CSAF: ICSA-21-161-01 Rockwell Automation FactoryTalk Services Platform
  25. CISA CSAF: ICSA-24-030-06 Rockwell Automation FactoryTalk Service Platform
  26. CISA CSAF: ICSA-26-202-07 Rockwell Automation FactoryTalk Services Platform
  27. CISA CSAF: ICSA-22-090-07 Rockwell Automation Studio 5000 Logix Designer
  28. CISA CSAF: ICSA-25-226-29 Rockwell Automation Studio 5000 Logix Designer
  29. CISA CSAF: ICSA-26-202-10 Rockwell Automation Studio 5000 Logix Designer
  30. CISA Known Exploited Vulnerabilities Catalog
  31. FIRST: Exploit Prediction Scoring System (EPSS)
  32. NVD: CVE-2019-6553 (RSLinx Classic)
Was this guide helpful?