Siemens SIMATIC WinCC is a Windows-based SCADA and HMI system, and SIMATIC PCS 7 is the distributed control system built on it. Siemens ProductCERT advisories from 2012 (SSA-027884) to November 2026 (SSA-970803 and SSA-979641) show five recurring CVE families: hard-coded or default credentials, crafted packets to the WinCC server, web server flaws, database and project-file paths to code execution, and weak authentication. The best known, CVE-2010-2772, is the hard-coded database password Stuxnet used.
As of 2026-11-28, no WinCC or PCS 7 CVE is in CISA's KEV catalog. The defence is the current Update for each product line, Encrypted Communication, a closed web server and a segmented cell.
Advisory facts in this guide come from Siemens ProductCERT advisories (SSA numbers), from CISA's ICS advisories and CSAF files, which republish them, and from NVD. Siemens lists fixes per product line (WinCC V7.5, V8.0, PCS 7 V9.1 and so on), so read the full product table of the advisory for your exact version before acting on any row below.
Key takeaways
- Siemens SIMATIC WinCC is a Windows-based SCADA and HMI system, and SIMATIC PCS 7 is the distributed control system built on it.
- The WinCC name covers several products with separate version lines, and Siemens writes advisories against each line separately.
- The table lists the WinCC and PCS 7 CVEs most likely to come up when a plant is matched against Siemens and CISA advisories.
- Siemens fixes each product line separately and names the fix by line, service pack and update.
What are WinCC, WinCC Unified and PCS 7?
The WinCC name covers several products with separate version lines, and Siemens writes advisories against each line separately. Siemens' own product descriptions, from the advisories cited below:
| Product | What Siemens calls it | Version strings seen in advisories |
|---|---|---|
| SIMATIC WinCC (V7, V8) | "a supervisory control and data acquisition (SCADA) system" (SSA-979641) | V7.4 SP1 Update 23, V7.5 SP2 Update 18, V8.0 Update 11, V8.1 Update 7 |
| SIMATIC PCS 7 | "a distributed control system (DCS) integrating SIMATIC WinCC, SIMATIC Batch, SIMATIC Route Control, OpenPCS 7 and other components" (SSA-883918) | V8.2 SP1, V9.0 SP3 UC06, V9.1 SP2 UC06 |
| SIMATIC WinCC Runtime Professional | "a visualization runtime platform used for operator control and monitoring of machines and plants" (SSA-970803), engineered in TIA Portal | V18 Update 5, V19 Update 3 |
| SIMATIC WinCC Unified PC Runtime and Unified Comfort Panels | "the new visualization runtime platform used for operator control and monitoring of machines and plants" (SSA-063511) | V16 to V21, V21 Update 2 |
| SIMATIC WinCC Runtime Advanced, WinCC flexible and HMI panels | Runtime Advanced is "a visualization runtime platform"; "SIMATIC HMI Panels are used for operator control and monitoring of machines and plants" (SSA-538778) | WinCC flexible 2008 SP3, V15.1 Update 6, V16 Update 4 |
PCS 7 carries WinCC inside it. Siemens' 2014 advisory SSA-134508 lists PCS 7 as affected "as WinCC is incorporated", and its fixes for PCS 7 are WinCC updates: PCS 7 V8.1 needed "WinCC V7.3 Update 2". An inventory that records only "PCS 7 V8.1" therefore cannot be matched; it needs the WinCC version on each operator station and server as well. WinCC OA (Open Architecture) is a different product with its own advisories and is not covered here.
Which CVE families appear in Siemens advisories for WinCC and PCS 7?
The table lists the WinCC and PCS 7 CVEs most likely to come up when a plant is matched against Siemens and CISA advisories. Scores are Siemens' from the SSA (CVSS v3.x where Siemens gives one, otherwise v2), with NVD's own score added where it differs; fixed versions are from the Siemens advisory or the CISA CSAF file that republishes it.
| CVE | Siemens (CISA) advisory | Products | Issue | Siemens score | Fix or main mitigation |
|---|---|---|---|---|---|
| CVE-2010-2772 | SSA-027884 (ICSA-12-205-01) | WinCC, PCS 7 | Pre-defined SQL Server credentials, CWE-798 | v2 10.0 (NVD v3.1 7.8) | WinCC V7.0 SP2 Update 1; PCS 7 V7.1 SP2 |
| CVE-2011-3321 | ICSA-11-244-01 | WinCC flexible Runtime, Runtime Advanced | Heap overflow in the Runtime Loader on 2308/tcp, CWE-119 | NVD v2 9.3 | Keep the loader (transfer mode) off; no fix |
| CVE-2011-4509 | ICSA-11-356-01 | WinCC flexible, HMI panels, Runtime Advanced | HMI web server default administrator password, CWE-1392 | NVD v2 10.0 | Set a password at setup (WinCC V11 SP2 Update 1, flexible 2008 SP3 documentation) |
| CVE-2014-8551 | SSA-134508 (ICSA-14-329-02D) | WinCC, PCS 7, TIA Portal V13 | Unauthenticated remote code execution with crafted packets | v2 10.0 | WinCC V7.2 Update 9; V7.3 Update 2; WinCC (TIA Portal) V13 Update 6 |
| CVE-2016-5743 | SSA-378531 (ICSA-16-208-01C) | WinCC, PCS 7, Runtime Professional | Unauthenticated remote code execution with crafted packets, CWE-20 | 9.8 | WinCC V7.3 Update 10; V7.4 Update 1; Runtime Professional V13 SP1 Update 9 |
| CVE-2018-4832 | SSA-348629 (ICSA-18-088-03) | WinCC, PCS 7, Runtime Professional | Crafted RPC messages stop communication; reboot needed, CWE-20 | 7.5 | WinCC V7.4 SP1 Update 4; PCS 7 V8.2 SP1; no fix for PCS 7 V8.1 and earlier |
| CVE-2019-10922 | SSA-705517 (ICSA-19-134-02) | WinCC, PCS 7, all versions | Unauthenticated code execution without Encrypted Communication, CWE-306 | 9.8 | Enable Encrypted Communication (default from WinCC V7.5) |
| CVE-2019-10916 | SSA-697412 (ICSA-19-134-08) | WinCC, PCS 7, WinCC in TIA Portal | SQL injection through a project file runs commands as the database server, CWE-89 | 9.1 (NVD 8.8) | WinCC V7.4 SP1 Update 11; V7.5 Update 3; TIA Portal V15.1 Update 3 |
| CVE-2019-10918 | SSA-697412 (ICSA-19-134-08) | WinCC, PCS 7, WinCC in TIA Portal | Low-privileged user runs commands as SYSTEM over DCOM, CWE-749 | 8.8 | Same as CVE-2019-10916 |
| CVE-2019-10935 | SSA-121293 (ICSA-19-192-02) | WinCC DataMonitor, PCS 7 | Authenticated upload of ASPX code to the DataMonitor web application, CWE-434 | 7.2 | WinCC V7.4 SP1 Update 11; V7.5 Update 3 |
| CVE-2019-19282 | SSA-270778 (ICSA-20-042-06) | WinCC, PCS 7, SIMATIC NET PC | Denial of service when Encrypted Communication is on, CWE-131 | 7.5 | WinCC V7.4 SP1 Update 14; V7.5 SP1 Update 1; PCS 7 V9.0 SP3; no fix for WinCC V7.3 |
| CVE-2020-15786 | SSA-542525 (ICSA-20-252-06) | HMI Basic, Comfort, Mobile and Unified Comfort Panels | Sm@rt Server passwords open to brute force, CWE-307 | 6.5 (NVD 9.8) | V16 Update 3; Unified Comfort Panels V16 Update 5 |
| CVE-2021-27384 | SSA-538778 (ICSA-21-131-12) | HMI Comfort and Mobile Panels, Runtime Advanced V15 and V16 | SmartVNC out-of-bounds access, possible code execution, CWE-788 | 9.8 | V15.1 Update 6; V16 Update 4 |
| CVE-2021-40358 | SSA-840188 (ICSA-21-315-03) | WinCC, PCS 7 | Path traversal in the WinCC web server: read, write or delete files, CWE-22 | 9.9 | WinCC V7.4 SP1 Update 19; V7.5 SP2 Update 5; PCS 7 V9.1 SP1; or disable the web server |
| CVE-2022-24287 | SSA-363107 (ICSA-22-132-06) | WinCC, PCS 7, Runtime Professional | Kiosk Mode escape when no default printer is set, CWE-1188 | 7.8 | WinCC V7.5 SP2 Update 8; no fix for WinCC V7.3 or PCS 7 V8.2 |
| CVE-2023-30897 | SSA-914026 (ICSA-23-166-07) | WinCC V7 | Weak folder permissions on a non-default install path, CWE-732 | 7.8 | V7.5.2.13 |
| CVE-2023-48363 | SSA-753746 (ICSA-24-046-12) | WinCC, PCS 7, Runtime Professional | RPC server denial of service, CWE-476 | 6.5 | WinCC V7.5 SP2 Update 15; V8.0 Update 4; PCS 7 V9.1 SP2 UC05; no fix for V7.4 |
| CVE-2023-50821 | SSA-730482 (ICSA-24-102-02) | WinCC, PCS 7, Runtime Professional | Login dialog buffer overflow, persistent denial of service, CWE-120 | 6.2 | WinCC V7.5 SP2 Update 16; V8.0 Update 5; PCS 7 V9.1 SP2 UC04 |
| CVE-2024-30321 | SSA-883918 (ICSA-24-193-16) | WinCC, PCS 7, Runtime Professional | Web application leaks users and passwords, unauthenticated, CWE-359 | 5.9 | WinCC V7.4 SP1 Update 23; V7.5 SP2 Update 17; V8.0 Update 5 |
| CVE-2024-35783 | SSA-629254 (ICSA-24-256-14) | WinCC, PCS 7, Process Historian, Information Server | Database server runs with elevated privileges; OS commands as administrator, CWE-250 | 9.1 | WinCC V7.5 SP2 Update 18; V8.0 Update 5; PCS 7 V9.1 SP2 UC06; no fix for V7.4 |
| CVE-2026-27662 | SSA-387223 (ICSA-26-134-07) | HMI Unified Comfort Panels | Control Panel escape to the web browser without authentication, CWE-1188 | 7.7 | V21 |
| CVE-2026-24349 | SSA-063511 (ICSA-26-174-01) | WinCC Unified PC Runtime | Certificate Manager stores key material in clear text, CWE-313 | 7.1 | V21 Update 2; no fix for V16 to V20 |
| CVE-2026-59241 | SSA-550198 (ICSA-26-295-13) | WinCC V7.5, V8.0, V8.1 | Database role permissions allow command execution on the host, CWE-266 | 8.8 | V8.0 Update 11; V8.1 Update 7; no fix for V7.5 |
| CVE-2026-58114 | SSA-970803 (ICSA-26-321-08) | WinCC, PCS 7, Runtime Professional, Process Historian | NTLM authentication can be relayed by a machine in the middle, CWE-1390 | 7.5 | No fix; encrypt SQL Server communication |
| CVE-2026-59082 | SSA-979641 (ICSA-26-321-09) | WinCC V7.5, V8.0, V8.1 Graphics Designer | Opening a file runs its active content, CWE-357 | 7.8 | No fix; open only trusted files |
Hard-coded and default credentials
The family started with a database password. Siemens advisory SSA-027884 says WinCC before V7.0 SP2 Update 1 and PCS 7 before V7.1 SP2 "utilize pre-defined SQL server credentials that allow administrative access to the database", and that these "cannot be changed or disabled by the user". The fix, released in 2010, "removes the pre-defined credentials and switches to Windows authentication mechanisms". Siemens scored it CVSS v2 10.0; NVD scores it CVSS v3.1 7.8 with a local attack vector. The CVE record says it was "demonstrated in the wild in July 2010 by the Stuxnet worm". Our hard-coded credentials guide covers how this class of flaw is found and removed.
On the HMI side, CVE-2011-4509 is a default administrator password on the HMI web server of WinCC flexible, WinCC V11 Runtime Advanced and SIMATIC HMI panels. CISA's ICSA-11-356-01 records Siemens' remedy as documentation: product documentation in WinCC V11 SP2 Update 1 and WinCC flexible 2008 SP3 "has been updated to tell the user how to set a proper password during initial setup". A panel commissioned without that step is still exposed. CVE-2020-15786 shows the same theme a decade later: SSA-542525 says HMI panels, including Unified Comfort Panels, "insufficiently block excessive authentication attempts" on the Sm@rt Server, so passwords could be brute-forced. Siemens scores it 6.5; NVD scores it 9.8.
Crafted packets to the WinCC server
Three advisories describe unauthenticated code execution against the WinCC server itself. For CVE-2014-8551, SSA-134508 says a component "could allow remote code execution for unauthenticated users if specially crafted packets are sent to the WinCC server". SSA-378531 repeated the pattern in 2016 with CVE-2016-5743, scored 9.8 by Siemens and NVD, and CVE-2016-5744, which let an attacker "extract arbitrary files from the WinCC station". Both advisories give the same interim advice: run WinCC and PCS 7 stations "within a trusted network" and, in 2016, use "Encrypted Communications" or a VPN tunnel.
CVE-2019-10922 made that setting the fix. SSA-705517 lists every WinCC and PCS 7 version as affected and says the flaw "can be exploited if the affected systems do not have 'Encrypted Communication' enabled"; Siemens and NVD both score it 9.8. Siemens adds that Encrypted Communication "is enabled by default starting with SIMATIC WinCC V7.5". The same setting completely mitigates CVE-2023-48363 and CVE-2023-48364, the RPC denial-of-service flaws in SSA-753746. It is not free of bugs either: CVE-2019-19282 in SSA-270778 is a denial of service that works "when encrypted communication is enabled", fixed in WinCC V7.4 SP1 Update 14 and V7.5 SP1 Update 1.
Web servers: WebNavigator, DataMonitor and the WinCC web server
WinCC's web components are the fastest way from an office network to the SCADA server. CVE-2019-10935 in SSA-121293 let an authenticated user of the WinCC DataMonitor web application "upload arbitrary ASPX code". CVE-2021-40358 in SSA-840188, scored 9.9 by Siemens, is a path traversal in which an attacker could "read, write or delete unexpected critical files"; Siemens' mitigation is "Disable the webserver or only enable it temporarily, when needed". CVE-2024-30321 in SSA-883918 could let "an unauthenticated remote attacker to retrieve information such as users and passwords", and Siemens' workaround is to "Restrict access to application webserver for trusted users only".
The database and project files
WinCC runs on an SQL Server database, the one whose pre-defined credentials SSA-027884 removed, and several CVEs turn database access into control of the host. CVE-2019-10916 in SSA-697412 is an SQL injection in which "an attacker with access to the project file could run arbitrary system commands with the privileges of the local database server". CVE-2024-35783 in SSA-629254 says the products "run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges". The October 2026 advisory SSA-550198, CVE-2026-59241, is a database role that is not restricted enough, and Siemens lists "Currently no fix is available" for WinCC V7.5. Files opened in the engineering tools are a further path: for CVE-2026-59082, SSA-979641 says the WinCC Graphics Designer can execute active content when opening files, and the only mitigation is to "only open files from trusted sources".
Authentication and local hardening
The newest advisory, SSA-970803 (CVE-2026-58114, 10 November 2026), says the affected WinCC, PCS 7, Process Historian and Information Server versions "do not properly secure their remote user authentication with the deprecated NTLM protocol", so an attacker in a machine-in-the-middle position could relay it and impersonate a user, for example against "a SQL server used by WinCC". No version has a fix; Siemens' mitigation is to configure the SQL Server database to encrypt its communication. Local issues complete the family: CVE-2022-24287 lets an authenticated user escape WinCC Kiosk Mode when no default printer is installed, CVE-2023-30897 is weak permissions on a non-default installation folder, and CVE-2026-24349 is clear-text key material in the WinCC Unified Certificate Manager.
Runtime Advanced, WinCC flexible and HMI panels
The panel line has its own history. CVE-2011-3321 is a heap overflow in the WinCC flexible Runtime and Runtime Advanced loader; CISA's ICSA-11-244-01 says it is reached "via a crafted packet to TCP port 2308", that the loader is "disabled by default and is only used when updating firmware", and that Siemens had no plans to patch it. CISA advises owners to "monitor network traffic to 2308/TCP". CVE-2021-27384, the SmartVNC flaw in SSA-538778, is fixed by updating WinCC in TIA Portal to V15.1 Update 6 or V16 Update 4 and then updating the panel. For the Unified Comfort Panels, CVE-2026-27662 in SSA-387223 lets an unauthenticated attacker reach the web browser through the Control Panel on firmware before V21.
How does Siemens version and fix WinCC and PCS 7?
Siemens fixes each product line separately and names the fix by line, service pack and update. The advisories above show four numbering schemes:
WinCC V7: version, SP, UpdateFixes read "V7.4 SP1 Update 23" or "V7.5 SP2 Update 18". Some advisories use the build form instead: SSA-914026 fixes CVE-2023-30897 in "V7.5.2.13", and SSA-027884 writes WinCC V7.0 SP2 Update 1 as "Version 7.0.2.1". A V7.5 SP2 Update 17 host is fixed for CVE-2024-30321 but not for CVE-2024-35783. WinCC V8: version, UpdateV8.0 and V8.1 fixes read "V8.0 Update 11" and "V8.1 Update 7". WinCC in TIA Portal: TIA Portal version, UpdateRuntime Professional, Runtime Advanced, Unified PC Runtime and panel firmware follow the TIA Portal release, such as "V19 Update 3" or "V21 Update 2". For panels, Siemens' instruction is often two steps: update WinCC (TIA Portal), then update the panel. PCS 7: release, SP, then a WinCC level or update packageOlder advisories name the WinCC update to install on PCS 7 ("PCS 7 V8.1: Upgrade to WinCC V7.3 Update 2"); newer ones name the PCS 7 package ("V9.1 SP2 UC06"). The PCS 7 add-ons (BATCH, Route Control, OpenPCS 7) carry their own fixes in the same advisory.
Older lines drop out of the fix tables. The advisories mark them "Currently no fix" rather than giving a version: WinCC V7.4 for CVE-2023-48363 and CVE-2024-35783, WinCC V7.3 and PCS 7 V8.2 for CVE-2022-24287, PCS 7 V8.1 and earlier for CVE-2018-4832, and WinCC Unified PC Runtime V16 to V20 for CVE-2026-24349. A station on one of those lines can only be fixed by moving to a newer line; until then, the advisory's mitigations and the network are the only controls. Our IEC 62443-2-3 patch management guide covers how to plan line upgrades on a running plant.
NVD data is uneven across the family. As of 2026-11-28, NVD has its own (Primary) score for the CVEs up to 2023, while CVE-2023-50821, CVE-2024-30321, CVE-2024-35783 and CVE-2026-59241 are Deferred, CVE-2026-27662, CVE-2026-58114 and CVE-2026-59082 are Awaiting Analysis, and CVE-2026-24349 carries only Siemens' score. A scanner that matches NVD CPEs alone misses most of the newer entries, so match against the Siemens or CISA CSAF product tree as well.
How should KEV and EPSS weigh on WinCC and PCS 7 findings?
As of 2026-11-28, the CISA KEV catalog (version 2026.11.27, 1,808 entries) has no WinCC or PCS 7 entry. Its two Siemens entries are a Siemens Software Center flaw and CVE-2016-8562 in the SIMATIC CP 1543-1. CVE-2010-2772 is not listed, even though its CVE record describes use by Stuxnet in 2010; KEV absence is not evidence that a flaw was never exploited.
The FIRST EPSS scores dated 2026-11-27, read on 2026-11-28, for the CVEs in this guide:
| CVE | EPSS | Percentile |
|---|---|---|
| CVE-2016-5743 | 0.105 | 0.965 |
| CVE-2011-3321 | 0.071 | 0.950 |
| CVE-2014-8551 | 0.053 | 0.933 |
| CVE-2016-5744 | 0.044 | 0.921 |
| CVE-2019-10922 | 0.026 | 0.863 |
| CVE-2021-27384 | 0.026 | 0.861 |
| CVE-2018-4832 | 0.024 | 0.849 |
| CVE-2014-8552 | 0.020 | 0.819 |
| CVE-2011-4509 | 0.020 | 0.812 |
| CVE-2019-10918 | 0.019 | 0.806 |
| CVE-2019-10916 | 0.015 | 0.753 |
| CVE-2020-15786 | 0.015 | 0.742 |
| CVE-2019-19282 | 0.013 | 0.715 |
| CVE-2021-40358 | 0.013 | 0.700 |
| CVE-2019-10935 | 0.013 | 0.700 |
| CVE-2024-35783 | 0.009 | 0.576 |
| CVE-2024-30321 | 0.008 | 0.520 |
| CVE-2026-59241 | 0.006 | 0.444 |
| CVE-2010-2772 | 0.005 | 0.394 |
| CVE-2026-58114 | 0.005 | 0.375 |
Every other CVE in the table above scored below 0.005. EPSS is low across the family, so rank by reachability and consequence. A WinCC server or web component reachable from outside its cell comes first, then unauthenticated code execution on a station without Encrypted Communication, then the database and credential issues that let one foothold take over the server. Our KEV and EPSS prioritization guide explains the method.
How do you harden WinCC and PCS 7 per Siemens and CISA guidance?
The steps below come from the advisories above, from Siemens' Operational Guidelines (Version 2.2.1, April 2024), which every recent SSA points to, and from the recommended practices CISA repeats in each ICS advisory, in the order that covers the most CVEs.
Install the current Update for each line, and move off lines with no fixRecord the full version string on every station, apply the fixed Update or UC level, and schedule the move from WinCC V7.4, V7.3, PCS 7 V8.x or Unified V16 to V20. The Operational Guidelines say "Siemens supports compatibility tests of Microsoft security patches" for PCS 7 and WinCC, and describe patch distribution through a central patch server and WSUS in the DMZ. Enable Encrypted CommunicationIt closes CVE-2019-10922 and fully mitigates CVE-2023-48363. Check projects upgraded from versions before V7.5, where it is not on by default. Disable web components that are not usedSSA-840188 says to disable the WinCC web server or enable it only when needed, and SSA-883918 says to restrict it to trusted users. Treat WebNavigator and DataMonitor as internet-facing services even inside the plant. Protect the databaseEncrypt SQL Server communication as SSA-970803 describes, keep database access to the WinCC servers and administrators that need it, and do not give operator accounts database rights (CVE-2026-59241, CVE-2024-35783). Set passwords on panels and runtimesChange default web server and Sm@rt Server passwords at commissioning (CVE-2011-4509, CVE-2020-15786), and keep the Runtime Advanced loader on 2308/tcp off except during updates (CVE-2011-3321). The Operational Guidelines say that if predefined default passwords are present, "they must be changed during system commissioning". Segment the cellThe Operational Guidelines describe "Separation between production and office networks", "Secure access via demilitarized zone" and a "cell protection concept" that segments production into protected cells. CISA's recommended practices in ICSA-19-134-02 add: minimize network exposure, keep control networks behind firewalls isolated from business networks, and use VPNs for remote access. The Purdue model guide shows where WinCC servers, clients and web servers sit. Harden the Windows hostsThe Operational Guidelines list user management, antivirus and allowlisting software for PC-based systems. SSA-363107 and SSA-914026 add: harden the host "to prevent local access by untrusted personnel", install a default printer for Kiosk Mode, and use the default installation path. Protect project filesThe Operational Guidelines ask for "protection mechanism for project files during their whole lifecycle (encrypted storage and transfer; access control; prevent them from being uploaded to online scanning engines; safe deletion of outdated files)". CVE-2019-10916 and CVE-2026-59082 both start from a file an attacker can influence.
What does a WinCC and PCS 7 triage look like? (worked example)
Synthetic example. The plant and installed versions are invented for illustration; the CVEs and fixed versions come from the Siemens advisories above.
A water treatment plant has two WinCC V7.5 SP2 Update 15 servers with WebNavigator enabled, one older WinCC V7.4 SP1 Update 19 station kept for a legacy line, and four HMI Comfort Panels on V16 Update 2.
| Station | Finding | Action |
|---|---|---|
| WinCC V7.5 SP2 Update 15 servers | Below Update 16 (CVE-2023-50821), Update 17 (CVE-2024-30321) and Update 18 (CVE-2024-35783); CVE-2026-59241, CVE-2026-58114 and CVE-2026-59082 apply with no fix for V7.5 | Install V7.5 SP2 Update 18 or later; plan the move to V8.1 Update 7 for CVE-2026-59241; restrict the web server to trusted users; encrypt SQL Server communication; open only trusted files in Graphics Designer |
| WinCC V7.4 SP1 Update 19 station | CVE-2023-48363 and CVE-2024-35783 with no fix for V7.4; below V7.4 SP1 Update 21 (CVE-2022-24287) and Update 23 (CVE-2024-30321) | Install V7.4 SP1 Update 23; enable Encrypted Communication; isolate the station in its own cell until the line is migrated |
| HMI Comfort Panels V16 Update 2 | Below V16 Update 3 (CVE-2020-15786) and V16 Update 4 (CVE-2021-27384) | Update WinCC (TIA Portal) to V16 Update 4 or later, then the panels; set Sm@rt Server and web server passwords |
What are the common pitfalls?
- Recording "PCS 7 V9.1" without the WinCC level. PCS 7 fixes are WinCC updates or UC packages, so the inventory needs both.
- Assuming Encrypted Communication is on. SSA-705517 names it as the default only from WinCC V7.5; check each station.
- Leaving WebNavigator or DataMonitor reachable from the office network. Web components carry the remote file and password leak CVEs.
- Treating "no fix" as "not affected". WinCC V7.4 and Unified V16 to V20 are affected by CVEs that Siemens will only fix on newer lines.
- Trusting KEV absence. CVE-2010-2772 was used by Stuxnet and is not in KEV as of 2026-11-28.
- Relying on NVD CPE matching. As of 2026-11-28, the 2024 to 2026 CVEs have no NVD analysis.
For the controllers below WinCC, see the S7-1200 and S7-1500 guide and the S7comm protocol guide; for the switches and routers in the same cells, the SCALANCE and RUGGEDCOM guide. Comparable SCADA platforms are covered in the AVEVA InTouch and System Platform guide and the Honeywell Experion guide.
AI-assisted analysis: what SoftWSP actually runs
SoftWSP identifies components and versions from a firmware image or a component list, and matches them against NVD, CISA KEV, FIRST EPSS and CISA's ICS advisories with deterministic code. AI then writes the plain-language summary, citing the component, version and record behind each finding, and an engineer reviews every report before it is sent.
For a WinCC or PCS 7 system, the useful input is the full version string of each server, client and engineering station (for example WinCC V7.5 SP2 Update 17 or PCS 7 V9.1 SP2 UC05), the TIA Portal version for Runtime Professional and Unified, and each HMI panel's article number and firmware. The OT Snapshot reads Zeek and ICSNPP logs from a mirror-port capture at connection level: which hosts talk to the WinCC servers and controllers, on which ports, and which remote-access sessions exist. It does not read installed updates, the Encrypted Communication setting, database permissions or project files, so those come from the asset list and are judged in the engineer review. For a whole machine line, see the machine builder report.
This guide draws on Siemens ProductCERT advisories SSA-027884, SSA-134508, SSA-378531, SSA-348629, SSA-705517, SSA-697412, SSA-121293, SSA-270778, SSA-542525, SSA-538778, SSA-840188, SSA-363107, SSA-914026, SSA-753746, SSA-730482, SSA-883918, SSA-629254, SSA-387223, SSA-063511, SSA-550198, SSA-970803 and SSA-979641, CISA ICS advisories and CSAF files, Siemens' Operational Guidelines 2.2.1, NVD and CVE.org records, CISA's KEV catalog version 2026.11.27 and FIRST EPSS data dated 2026-11-27, all read on 2026-11-28.
Put this guide to work
Frequently asked questions
Is CVE-2010-2772, the Stuxnet WinCC password, in CISA's KEV catalog?
No. As of 2026-11-28, CISA's Known Exploited Vulnerabilities catalog (version 2026.11.27, 1,808 entries) has two Siemens entries, a Siemens Software Center flaw and CVE-2016-8562 in the SIMATIC CP 1543-1, and no WinCC or PCS 7 entry. That includes CVE-2010-2772, even though its CVE record says the hard-coded WinCC database password was used in the wild in July 2010 by the Stuxnet worm. Siemens advisory SSA-027884 says the flaw affected WinCC before V7.0 SP2 Update 1 and PCS 7 before V7.1 SP2, and that the update switches to Windows authentication.
How does Siemens number WinCC and PCS 7 fixes?
By product line, then service pack and update. A WinCC V7 fix reads like "V7.5 SP2 Update 18"; WinCC V8 fixes read "V8.0 Update 11" or "V8.1 Update 7". WinCC in TIA Portal (Runtime Professional, Runtime Advanced, Unified) follows the TIA Portal version, such as "V19 Update 3" or "V21 Update 2". PCS 7 fixes name the PCS 7 release with a WinCC level or an update package, such as "V9.1 SP2 UC06". Siemens fixes each line separately, so a host on V7.5 SP2 Update 17 needs V7.5 SP2 Update 18 for CVE-2024-35783, not a V8 update.
Which WinCC or PCS 7 vulnerabilities have no fix?
Several, as of 2026-11-28. For CVE-2026-59241 (SSA-550198) Siemens lists no fix for WinCC V7.5; V8.0 and V8.1 are fixed in V8.0 Update 11 and V8.1 Update 7. CVE-2026-59082 in the WinCC Graphics Designer (SSA-979641) and CVE-2026-58114, an NTLM relay weakness in WinCC, PCS 7 and related products (SSA-970803), have no fix for any listed version. Older lines also drop out: Siemens lists no fix for WinCC V7.4 for CVE-2023-48363 and CVE-2024-35783, and none for WinCC Unified PC Runtime V16 to V20 for CVE-2026-24349. For those, the mitigations in the advisory and network isolation are the fix.
What is "Encrypted Communication" in WinCC and PCS 7 and why does it matter?
It is a WinCC and PCS 7 feature that, in Siemens' words in SSA-753746, makes WinCC, WinCC Runtime Professional and PCS 7 stations "communicate via encrypted channels". Siemens advisory SSA-705517 says CVE-2019-10922, an unauthenticated remote code execution flaw scored 9.8 by Siemens and NVD, can be exploited only if Encrypted Communication is not enabled, and that the setting is on by default starting with WinCC V7.5. For CVE-2023-48363 and CVE-2023-48364, SSA-753746 says enabling it "completely mitigates the vulnerability". Siemens names that default only from V7.5, so check the setting on every station rather than assuming it.
Can SoftWSP tell me whether my WinCC or PCS 7 stations are affected?
SoftWSP matches the components and versions it is given against NVD, CISA KEV, FIRST EPSS and CISA's ICS advisories, and AI writes a summary that cites the record behind each finding; an engineer reviews it before delivery. For WinCC and PCS 7 the useful input is the exact product and version string of each station, such as WinCC V7.5 SP2 Update 17 or PCS 7 V9.1 SP2 UC05, plus HMI panel firmware. Its passive OT Snapshot reads Zeek and ICSNPP logs at connection level, which shows which hosts talk to the WinCC servers and on which ports; it does not read installed updates, the Encrypted Communication setting or project files, so those come from the asset list.
Sources
- Siemens ProductCERT SSA-027884: Insecure SQL Server Authentication in SIMATIC WinCC (CVE-2010-2772)
- Siemens ProductCERT SSA-134508: Vulnerabilities in SIMATIC WinCC, PCS 7 and WinCC in TIA Portal (CVE-2014-8551, CVE-2014-8552)
- Siemens ProductCERT SSA-378531: Vulnerabilities in SIMATIC WinCC, PCS 7 and WinCC Runtime Professional (CVE-2016-5743, CVE-2016-5744)
- Siemens ProductCERT SSA-348629: Denial-of-Service Vulnerability in SIMATIC PCS 7, WinCC, WinCC Runtime Professional and SIMATIC NET PC Software (CVE-2018-4832)
- Siemens ProductCERT SSA-705517: Vulnerability in SIMATIC WinCC and SIMATIC PCS 7 (CVE-2019-10922)
- Siemens ProductCERT SSA-697412: Vulnerabilities in SIMATIC PCS 7, WinCC and TIA Portal (CVE-2019-10916, CVE-2019-10918)
- Siemens ProductCERT SSA-121293: Vulnerability in SIMATIC WinCC DataMonitor (CVE-2019-10935)
- Siemens ProductCERT SSA-270778: Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC and SIMATIC NET PC Software (CVE-2019-19282)
- Siemens ProductCERT SSA-542525: Authentication Vulnerabilities in SIMATIC HMI Products (CVE-2020-15786)
- Siemens ProductCERT SSA-538778: SmartVNC Vulnerabilities in SIMATIC HMI/WinCC Products (CVE-2021-27384)
- Siemens ProductCERT SSA-840188: Multiple Vulnerabilities in SIMATIC WinCC Affecting Other SIMATIC Software Products (CVE-2021-40358)
- Siemens ProductCERT SSA-363107: An Improper Initialization Vulnerability Affects SIMATIC WinCC Kiosk Mode (CVE-2022-24287)
- Siemens ProductCERT SSA-914026: Local Code Execution Vulnerability in SIMATIC WinCC V7 (CVE-2023-30897)
- Siemens ProductCERT SSA-753746: Denial of Service Vulnerabilities in SIMATIC WinCC Affecting Other SIMATIC Software Products (CVE-2023-48363)
- Siemens ProductCERT SSA-730482: Denial of Service Vulnerability in SIMATIC WinCC (CVE-2023-50821)
- Siemens ProductCERT SSA-883918: Information Disclosure Vulnerability in SIMATIC WinCC (CVE-2024-30321)
- Siemens ProductCERT SSA-629254: Remote Code Execution Vulnerability in SIMATIC SCADA and PCS 7 systems (CVE-2024-35783)
- Siemens ProductCERT SSA-387223: Unauthenticated Control Panel Escape Vulnerability on SIMATIC HMI Unified Comfort before V21.0 (CVE-2026-27662)
- Siemens ProductCERT SSA-063511: Insufficient protection of key material in WinCC Certificate Manager (CVE-2026-24349)
- Siemens ProductCERT SSA-550198: Authenticated Remote Code Execution in WinCC (CVE-2026-59241)
- Siemens ProductCERT SSA-970803: Insecure User Authentication in SIMATIC SCADA and PCS 7 systems (CVE-2026-58114)
- Siemens ProductCERT SSA-979641: Implicit Execution of Active Content when Opening Files Vulnerability in SIMATIC WinCC Graphics Designer (CVE-2026-59082)
- Siemens: Cybersecurity for Industry, Operational Guidelines, Version 2.2.1 (April 2024)
- CISA CSAF: ICSA-12-205-01 Siemens WinCC Insecure SQL Server Authentication (CVE-2010-2772)
- CISA CSAF: ICSA-11-244-01 Siemens WinCC flexible Runtime Heap Overflow (CVE-2011-3321)
- CISA CSAF: ICSA-11-356-01 Siemens SIMATIC HMI Authentication Vulnerabilities (CVE-2011-4509)
- CISA CSAF: ICSA-12-030-01A Siemens SIMATIC WinCC Vulnerabilities (Update A)
- CISA CSAF: ICSA-14-329-02D Siemens SIMATIC WinCC, PCS7, and TIA Portal Vulnerabilities (Update D)
- CISA CSAF: ICSA-16-208-01C Siemens SIMATIC WinCC, PCS 7, and WinCC Runtime Professional (Update C)
- CISA CSAF: ICSA-19-134-02 Siemens SIMATIC WinCC and SIMATIC PCS 7 (CVE-2019-10922)
- CISA CSAF: ICSA-21-315-03 Siemens SIMATIC WinCC (Update E)
- CISA CSAF: ICSA-24-256-14 Siemens SIMATIC SCADA and PCS 7 Systems (CVE-2024-35783)
- CISA CSAF: ICSA-26-295-13 Siemens WinCC (CVE-2026-59241)
- CISA CSAF: ICSA-26-321-08 Siemens SIMATIC (CVE-2026-58114)
- NVD: CVE-2010-2772
- NVD: CVE-2016-5743
- NVD: CVE-2019-10922
- NVD: CVE-2020-15786
- CVE record (CVE Services API): CVE-2010-2772
- CISA Known Exploited Vulnerabilities catalog
- FIRST: Exploit Prediction Scoring System (EPSS)
About this guide
SoftWSP OT/ICS Desk
Covers the OT/ICS security cluster: 99 guides.

In this cluster
Questions about this page?