CVE-2019-10943 lets an attacker with access to port 102/tcp who can change the user program make a Siemens S7-1200 or S7-1500 CPU run code that differs from the source stored on it. NVD scores it 7.5; Siemens scores it 5.3. Siemens SSA-232418 lists all versions as affected, with no fix as of 2026-11-19.
Vulnerability summary
CVSS base score
7.5
High severity
EPSS score (FIRST)
1.0%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2019-10943 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| SIMATIC S7-1200 CPU family (incl. SIPLUS variants) | cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:* | All versions; no fix as of 2026-11-19 (Siemens SSA-232418). NVD's CPE covers only versions before 4.4 |
| SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) | cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:* | All versions; no fix as of 2026-11-19 (Siemens SSA-232418). NVD's CPE covers only versions before 2.8.1 |
| SIMATIC Drive Controller family | — | All versions; no fix as of 2026-11-19 (Siemens SSA-232418) |
| SIMATIC S7-1500 Software Controller | cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:* | All versions; no fix as of 2026-11-19 (Siemens SSA-232418). NVD's CPE covers only versions before 20.8 |
| SIMATIC ET 200SP Open Controller CPU 1515SP PC and CPU 1515SP PC2 (incl. SIPLUS variants) | cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:* | All versions; no fix as of 2026-11-19 (Siemens SSA-232418) |
| SIMATIC S7-PLCSIM Advanced | cpe:2.3:a:siemens:simatic_s7_plcsim_advanced:*:*:*:*:*:*:*:* | All versions; no fix as of 2026-11-19 (Siemens SSA-232418). NVD's CPE covers only versions before 3.0 |
What does this mean for affected devices?
NVD carries the Siemens description: "An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program." An engineer who reads the program back "can receive different source code that is not actually running on the device." NVD's Primary score is CVSS v3.1 7.5 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N) with CWE-345 (insufficient verification of data authenticity); the Siemens CNA classes it CWE-353 (missing support for integrity check). The record was published on 2019-08-13 (NVD, CVE record).
Why does Siemens score it 5.3 and NVD 7.5?
Siemens ProductCERT SSA-232418 scores CVE-2019-10943 at CVSS v3.1 5.3 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:T/RC:C). The only base-metric difference is integrity impact: Siemens rates it low, NVD high. CISA's ICSA-19-344-06 CSAF uses 5.3 with CWE-353.
What does the mismatch mean for the plant?
The S7-1200 or S7-1500 runs one program while the source stored on the CPU, the code an engineer uploads into TIA Portal, shows another. An attacker who can change the user program over 102/tcp could hide logic from the engineering station. Claroty Team82 ties SSA-232418 to the Rogue7 research, in which a rogue engineering station hid code in user memory that the TIA engineering station could not see, and says Siemens "partially resolved this issue and provided mitigations". Do not treat a clean upload as proof of what the CPU runs.
Which products are affected, and is there a fix?
SSA-232418 V1.4 (2022-08-09) lists all versions of these products as affected, with no fix for CVE-2019-10943 as of 2026-11-19:
| Product (Siemens wording) | Affected |
|---|---|
| SIMATIC S7-1200 CPU family (incl. SIPLUS) | all versions |
| SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS) | all versions |
| SIMATIC Drive Controller family | all versions |
| SIMATIC S7-1500 Software Controller | all versions |
| SIMATIC ET 200SP Open Controller CPU 1515SP PC and PC2 (incl. SIPLUS) | all versions |
| SIMATIC S7-PLCSIM Advanced | all versions |
Updates such as S7-1200 V4.4.0 and S7-1500 V2.8.1 fix the companion flaw CVE-2019-10929, not this one. NVD's CPE stops at the versions before those updates (S7-1200 before 4.4, S7-1500 before 2.8.1, Software Controller and CPU 1515SP PC2 before 20.8, PLCSIM Advanced before 3.0) and has no Drive Controller entry, so an NVD-keyed scanner clears current firmware that Siemens still lists as affected. The CISA CSAF also maps the update steps to CVE-2019-10943 while its product tree marks the later versions as affected; go by Siemens.
How do you mitigate it?
Siemens lists password protection for S7 communication. In practice, set access protection on every CPU and keep 102/tcp reachable only from known engineering stations; CISA's CSAF also points to the CPU's Access Protection feature, which prohibits unauthorized changes to user code. Our S7comm security guide and the S7-1200/S7-1500 vulnerability guide cover these controls. CVE-2020-15782 goes further on the same port, and CVE-2020-28400 is a PROFINET flaw in S7-1200 CPUs.
CVE-2019-10943 is not in the CISA KEV catalog as of 2026-11-19 (catalog version 2026.11.18, 1,786 entries). FIRST EPSS gives it 0.00952, the 62.0th percentile, in the 2026-11-18 dataset (CISA KEV, FIRST EPSS).
Evidence
- NVD (read 2026-11-19): status Modified; published 2019-08-13; NVD Primary CVSS v3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N, v2 5.0; CWE-345 (NVD), CWE-353 (Siemens); CPE: S7-1200 CPU firmware before 4.4, S7-1500 CPU firmware before 2.8.1, CPU 1515SP PC2 firmware before 20.8, CPU 1515SP PC firmware without limit, S7-1500 Software Controller before 20.8, PLCSIM Advanced before 3.0; no Drive Controller entry. — NVD
- Siemens SSA-232418 V1.4 (published 2019-08-13, updated 2022-08-09), read 2026-11-19: CVE-2019-10943 user program can be modified so running code differs from stored source; attacker needs network access to 102/tcp and must be able to change the user program; CVSS v3.1 5.3 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:T/RC:C; CWE-353; Drive Controller, CPU 1515SP PC and PC2, S7-1200, S7-1500, S7-1500 Software Controller and S7-PLCSIM Advanced affected in all versions with no fix for CVE-2019-10943; mitigation password protection for S7 communication; V1.4 added Drive Controller and CPU 1515SP PC. — Siemens ProductCERT SSA-232418
- CISA ICSA-19-344-06 CSAF (Update B, 2020-03-10), read 2026-11-19: CVE-2019-10943 CWE-353, CVSS v3.0 5.3; product tree marks S7-1200 >= 4.4.0, S7-1500 >= 2.8.1, Software Controller and CPU 1515SP PC2 >= 20.8, PLCSIM Advanced >= 3.0 and Drive Controller as affected only by CVE-2019-10943, while the vendor_fix entries are also attached to CVE-2019-10943; mitigation: Access Protection feature. — CISA CSAF ICSA-19-344-06
- Claroty Team82, read 2026-11-19: in the Rogue7 attack a rogue engineering station hid code in user memory invisible to the TIA engineering station; Siemens partially resolved this and provided mitigations, as documented in SSA-232418. — Claroty Team82
- CVE record (checked 2026-11-19): state PUBLISHED, CNA Siemens, published 2019-08-13; CNA CWE-353, no CNA CVSS metric; reference SSA-232418. — CVE.org
- Not in the CISA KEV catalog, version 2026.11.18 (1,786 entries), checked 2026-11-19. — CISA KEV
- EPSS 0.00952, percentile 0.61994, dataset 2026-11-18, read 2026-11-19. — FIRST EPSS

Related advisories
Sources
- NVD
- Siemens ProductCERT SSA-232418: Vulnerabilities in SIMATIC S7-1200 and SIMATIC S7-1500 CPU Families
- CISA CSAF: ICSA-19-344-06 Siemens SIMATIC S7-1200 and S7-1500 CPU Families (machine-readable advisory)
- Claroty Team82: The Race to Native Code Execution in PLCs (Rogue7 and SSA-232418 background)
- CVE.org record CVE-2019-10943 (CNA: Siemens)
- CISA KEV
- FIRST EPSS
Frequently asked questions
Is there a firmware fix for CVE-2019-10943?
No. As of 2026-11-19, SSA-232418 lists all versions of the S7-1200 and S7-1500 CPU families, Drive Controller, S7-1500 Software Controller, ET 200SP Open Controller and S7-PLCSIM Advanced as affected, with no fix (per Siemens SSA-232418).
Does updating to S7-1200 V4.4.0 or S7-1500 V2.8.1 help?
Those updates fix CVE-2019-10929 from the same advisory. Siemens lists S7-1200 V4.4.0 and later and S7-1500 V2.8.1 and later as still affected by CVE-2019-10943 (per Siemens SSA-232418).
What does an attacker need to exploit CVE-2019-10943?
Network access to port 102/tcp and the ability to change the user program on the CPU. The result is that the running code differs from the source an engineer reads back (per Siemens SSA-232418).
How do I reduce the risk?
Apply password protection for S7 communication and restrict 102/tcp to known engineering stations; CISA also points to the CPU's Access Protection feature, which prohibits unauthorized changes to user code (per Siemens SSA-232418 and CISA ICSA-19-344-06).
Questions about this page?