Hirschmann industrial switches, routers and firewalls from Belden had no entry in the CISA KEV catalog as of 2026-11-21, but Belden security bulletins, CISA ICS advisories and NVD list more than 20 CVEs for their HiOS, Classic, HiSecOS and GECKO firmware lines. Most of these flaws are reached through the management plane: the web server on TCP 80 and 443, SSH, Telnet, SNMP and the HiDiscovery protocol. The fixes are firmware updates per line, plus the hardening Hirschmann's own security manual describes: switch HiDiscovery and HTTP off, replace the admin/private account, restrict management to known IP addresses on a dedicated VLAN, and keep bundled components such as OpenSSL current.
Key takeaways
- Hirschmann ships several operating systems, and every Belden bulletin gives fixed versions per operating system and product family, so first record which line each device runs.
- The services in this table are the attack surface that Belden's bulletins and Hirschmann's manuals describe.
- Read the authentication flaws first.
- Belden publishes separate bulletins when a bundled open-source component is affected, and the fixed versions there differ from the ones for Hirschmann's own code.
Which Hirschmann product lines does this guide cover?
Hirschmann ships several operating systems, and every Belden bulletin gives fixed versions per operating system and product family, so first record which line each device runs. The table uses the product names as Belden's bulletins and CISA's advisories print them.
| Operating system | Product families named in Belden or CISA advisories | Device type |
|---|---|---|
| HiOS | RSP, RSPE, RSPS, RSPL, MSP, EES, EESX, GRS (including GRS1020/1030 and GRS1040), OS, RED, BRS, BXS, DRAGON, RDD | Managed rail, rack and backbone switches; some models support HSR redundancy rings |
| Classic switch software | RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, OCTOPUS | Managed switches on the Classic platform; Belden splits them into L2E, L2P, L3E, L3P and L2B (RSB) |
| HiSecOS | EAGLE (CISA names EAGLE20/30) | Industrial firewalls ("Firewall Products" in BSECV-2021-27) |
| Classic Firewall | EAGLE, EAGLE One | Firewalls on the Classic platform |
| Lite Managed | GECKO | Lite managed switches |
| HiEOS | LRS (LRS11 in BSECV-2024-02) | Devices on HiEOS firmware; Belden's bulletins name only the LRS |
Belden also publishes bulletins for the HiLCOS wireless (BAT) products and the Industrial HiVision management software; those are outside this guide. A HiOS fix often exists in several release lines at once. For example, CVE-2026-89025 is fixed in 07.1.12, 08.7.10, 09.0.13, 09.3.03, 10.3.08 and 10.5.00, so "HiOS 09" is not a complete inventory entry: you need the full version string.
How are Hirschmann switches managed and reached?
The services in this table are the attack surface that Belden's bulletins and Hirschmann's manuals describe. Ports and delivery states come from the HiOS user manual Security for the RSP (HiOS-2A Release 10.0, 04/2025) and the RSP graphical user interface reference for Release 10.3.
| Service | Default port | HiOS delivery state | What Hirschmann recommends for operation |
|---|---|---|---|
| HTTP web server | TCP 80 | Enabled, redirects to HTTPS | Disabled |
| HTTPS web server | TCP 443 | Enabled, self-signed certificate | Enabled, with your own certificate |
| SSHv2 | TCP 22 | Enabled | Enabled, with a dedicated host key |
| Telnet | TCP 23 | Disabled | Disabled |
| SNMPv1/v2 | UDP 161 | Disabled | Disabled; if needed, at least disable write access |
| SNMPv3 | UDP 161 | Enabled | Enabled, with SHA authentication and AES encryption |
| HiDiscovery protocol v1/v2 | Reached through ports in the management VLAN | On, with readWrite access | Off after initial use |
| Modbus TCP, EtherNet/IP, PROFINET, IEC 61850-MMS, OPC UA server | Industrial protocol services | Disabled | Disabled unless the control system needs them |
HiDiscovery deserves special attention. The HiOS reference says the HiDiscovery software can find Hirschmann devices and assign or change their IP parameters even when they have invalid or no IP parameters, and its default access mode is readWrite. Anyone on the management VLAN with that tool can re-address a switch. Older Classic switches differ in defaults: Belden's BSECV-2016-2 says that by default Classic switches build the SNMPv1/v2 read-only and read-write community strings from the "user" and "admin" passwords, so anyone who sniffs SNMPv1/v2 traffic may recover the switch passwords.
The industrial protocol row matters because those services run on the switch itself. Belden's BSECV-2019-14 shows the risk: on HiOS 05.0.00 to 08.0.00 with EtherNet/IP enabled, a UDP EtherNet/IP packet whose header length exceeds the real packet length can crash or hang the stack (CVE-2020-37216). Our EtherNet/IP and CIP security guide explains why that protocol has no authentication of its own.
Which vulnerability families appear in Belden and CISA advisories?
The recurring families are web server authentication bypass, memory corruption and reboot flaws in the web server, password and default-account weaknesses, privilege escalation on HiSecOS firewalls, and denial of service through industrial or redundancy protocols. Scores are CVSS v3.x unless marked; the scorer is named in brackets. "VulnCheck" is the CNA that published many Hirschmann CVEs in 2026; "Belden" is the score printed in the Belden bulletin.
| CVE | Products and affected versions | What it allows | Score (scorer) | Fix |
|---|---|---|---|---|
| CVE-2016-2509 (also CVE-2016-15058) | Classic L2E, L2P, L3E, L3P 09.0.05 and lower; Classic L2B (RSB) 05.3.06 and lower | SNMPv1/v2 community strings synchronized with switch passwords and sent in clear text | 5.3 (NVD); 8.1 for CVE-2016-15058 (VulnCheck) | 09.0.06 or 05.3.07, then disable password sync and SNMPv1/v2 (BSECV-2016-2) |
| CVE-2017-5163, CVE-2017-6036, CVE-2017-6038, CVE-2017-6040 | GECKO Lite Managed switch 2.0.00 and earlier | Copy of a downloaded configuration file, with password hashes, readable without authentication; SSRF; CSRF; information exposure | 5.9, 6.5, 7.1, 5.3 (NVD) | 02.0.01 (ICSA-17-026-02A) |
| CVE-2018-5465, CVE-2018-5469 and three others | Classic RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, OCTOPUS | Web session fixation, no limit on login attempts, sensitive data in GET query strings, clear-text and weakly encrypted web traffic | 7.5 (CISA) and 8.8 (NVD) for 5465; 7.5 (CISA) and 9.8 (NVD) for 5469 | No firmware fix in ICSA-18-065-01; mitigations only |
| CVE-2018-25236 | HiOS 05.0.07 and lower, 06.1.04 and lower, 06.2.00; HiSecOS EAGLE 03.0.02 and lower | Crafted HTTP requests receive the authentication status and privileges of a previously authenticated user | 8.1 (Belden); 9.8 (VulnCheck) | HiOS 06.1.05 or 07.0.00; HiSecOS 03.0.03 or 03.1.00 (BSECV-2017-15) |
| CVE-2018-25237 | Classic Firewall EAGLE and EAGLE One 05.3.02 and before, with RADIUS user authentication | Password over 128 characters overflows a fixed buffer in the HTTPS login; reboot or code execution | 9.8 (VulnCheck) | 05.3.03 (BSECV-2018-04) |
| CVE-2020-6994 | HiOS 07.0.02 and lower (RSP, RSPE, RSPS, RSPL, MSP, EES, EESX, GRS, OS, RED); HiSecOS EAGLE20/30 03.2.00 and lower | Buffer overflow in URL argument parsing; unauthenticated remote compromise | 9.8 (CISA, NVD) | HiOS 07.0.03, HiSecOS 03.3.00 (ICSA-20-091-01) |
| CVE-2020-9307 | OS2, RSP, RSPE before HiOS 08.3.00 | Adjacent attacker causes an infinite loop on an HSR ring port, breaking redundancy | 6.5 (NVD) | HiOS 08.3.00 |
| CVE-2020-37216 | HiOS 05.0.00 to 08.0.00 with EtherNet/IP enabled | Malformed EtherNet/IP UDP packets crash or hang the switch | 7.5 (VulnCheck) | 08.1.00 or 07.1.01, depending on product (BSECV-2019-14) |
| CVE-2021-27734 | HiOS 07.1.01, 07.1.02, 08.1.00 to 08.5.xx; HiSecOS 03.3.00 to 03.5.01 | Remote attackers change the credentials of existing users | 9.8 (NVD) | HiOS 08.6.00 or 07.1.03, HiSecOS 04.1.00 (CERT-FR, citing Belden BSECV-2020-10) |
| CVE-2023-7342 | HiSecOS EAGLE 03.4.00 up to 04.0.xx | Users with the operator or auditor role escalate to administrator through the web server; default configuration not affected | 8.8 (Belden) | 04.1.00 (BSECV-2021-07) |
| CVE-2023-53908 | HiSecOS 04.0.01 | Authenticated user changes own role to administrator through NETCONF XML | 8.8 (VulnCheck) | No Belden bulletin linked in NVD |
| CVE-2024-14034 | HiEOS LRS11 lower than 01.1.00 | Unauthenticated authentication bypass in the HTTP(S) management module | 9.8 (Belden) | 01.1.00 or later (BSECV-2024-02, NVD) |
| CVE-2025-15620 | HiOS Switch Platform since 09.1.00 | HTTP GET request to a specific endpoint reboots the switch | 9.3 (Belden); 8.6 (NVD) | 09.4.05 or 10.3.01 (PSIRT-2) |
| CVE-2026-89025 | HiOS Switch Platform 07.1.11, 08.7.09, 09.0.12, 09.3.02, 10.3.07, 10.4.00 and lower | Crafted HTTP(S) request reboots the switch; temporary denial of service | 8.7 CVSS v4 (Belden); 7.5 (VulnCheck) | 07.1.12, 08.7.10, 09.0.13, 09.3.03, 10.3.08 or 10.5.00 (PSIRT-6) |
Read the authentication flaws first. CVE-2018-25236, CVE-2020-6994, CVE-2021-27734 and CVE-2024-14034 each let an unauthenticated network attacker take over the device or its accounts, and Belden says CVE-2018-25236 allows configuration download or upload and firmware changes. The coding patterns behind them are covered in how to fix authentication bypass in embedded firmware, and the Classic password sync and the admin/private delivery account belong to the problem class in how to fix hard-coded credentials in embedded firmware.
For the Classic switches, CISA's ICSA-18-065-01 lists every RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS and OCTOPUS version as affected and gives only mitigations: disable HTTP for remote management, use HTTPS or SSH, use complex passwords, use the "Restricted Management Access" feature to allow known IP addresses only, and disable remote management access when not in use.
Which third-party components does Belden list for these devices?
Belden publishes separate bulletins when a bundled open-source component is affected, and the fixed versions there differ from the ones for Hirschmann's own code. Four bulletins cover the switch and firewall lines:
- OpenSSL, BSECV-2023-05 (version 1.1, updated 2024-06-25): CVE-2023-0286 (X.400 type confusion, 7.4 per Belden), CVE-2022-4304 (RSA timing side channel, 5.9), CVE-2023-0215 (7.5) and CVE-2022-4450 (7.5). Fixed versions: HiOS RSP, RSPE, MSP40, GRS, OS, BRS and BXS 09.4.00 or higher; HiOS DRAGON, MSP30 and RDD 09.0.08 or higher; HiOS RSP-2S, RSPL, RED, RSPS and GRS1020/30 07.1.08 or higher; Classic switches 09.1.10 or higher; HiSecOS EAGLE 04.6.02 or higher; Classic Firewall EAGLE One 05.4.04 or higher; HiEOS LRS 01.1.00 or higher; GECKO 02.4.00 or higher.
- libexpat, BSECV-2022-26 (2023-04-25): CVE-2022-40674 (9.8 per Belden) and CVE-2022-43680 (7.5). Fixed in HiOS 09.2.00 (with 09.0.06 and 07.1.08 for the older lines), Classic 09.1.08, HiSecOS EAGLE 04.4.00 and GECKO 2.3.3. Belden's mitigation for HiOS and HiSecOS is to disable the HTTP/HTTPS server or restrict it to trusted IP addresses.
- uClibc, BSECV-2021-27 (2023-07-25): CVE-2021-43523 (9.6 per Belden), DNS name handling in HiSecOS EAGLE 04.2.01 or lower, fixed in 04.3.00.
- NTP, BSECV-2021-15 (2023-07-25): CVE-2020-15025, CVE-2020-13817, CVE-2020-11868 and CVE-2018-8956 in HiSecOS EAGLE 3.5.0 to 4.2.02, fixed in 04.3.00; Belden's mitigation is to configure only trusted NTP servers and prevent spoofed NTP packets.
None of the Belden bulletins cited in this guide lists an OpenSSH CVE for these product lines, so treat SSH exposure through the management access controls below and ask Belden support about the OpenSSH version in your release. The OpenSSL guide, the zlib, Expat and libxml2 guide and the glibc, uClibc and musl guide explain how those component flaws behave in embedded firmware.
How should KEV and EPSS shape the order of work?
No Hirschmann or Belden product appears in the CISA KEV catalog data as of 2026-11-21 (catalog version 2026.11.20, 1,790 entries), and none of the CVEs above, including the third-party ones, is listed. FIRST EPSS scores dated 2026-11-20 are low for Hirschmann's own code: the highest are CVE-2018-5469 at 0.02863, CVE-2017-5163 at 0.01901, CVE-2018-5465 at 0.01733 and CVE-2020-6994 at 0.01646. Every Hirschmann CVE first published in 2026, including CVE-2026-89025 at 0.00770, scores below 0.01. The bundled OpenSSL flaws score much higher: CVE-2023-0286 at 0.61757 (99.2nd percentile), CVE-2022-4450 at 0.28590 and CVE-2022-4304 at 0.23509.
EPSS is a probability of exploitation activity across all systems, not a statement about Hirschmann devices, so use it for ordering rather than dismissal. A practical order is:
- Any Hirschmann management interface (TCP 80, 443, 22, 23 or UDP 161) reachable from outside its cell or from the internet. CISA's BOD 23-02 guide on internet-exposed management interfaces explains why exposed admin consoles come first.
- Devices below the fixes for unauthenticated takeover: CVE-2020-6994, CVE-2018-25236, CVE-2021-27734 and CVE-2024-14034.
- HiOS devices in the PSIRT-2 and PSIRT-6 ranges, because a single unauthenticated request reboots the switch and takes its traffic down with it.
- OpenSSL and libexpat component fixes, then the remaining privilege escalation and protocol denial-of-service fixes.
The KEV and EPSS prioritization guide explains how to combine the two signals.
Why do Hirschmann NVD records need care?
Three things make Hirschmann CVE data harder to match than it looks. First, VulnCheck assigned many IDs in April 2026 for bulletins Belden published between 2016 and 2024, so a 2018 flaw can carry a 2026 publication date, and as of 2026-11-21 records such as CVE-2018-25236, CVE-2018-25237, CVE-2020-37216 and CVE-2024-14034 are Awaiting Analysis with no NVD CPE configuration; CVE-2025-15620 is the exception, analyzed with a CPE configuration. A scanner that matches NVD CPE data alone will miss them.
Second, scores and product names disagree between sources. Belden scores CVE-2018-25236 at 8.1 and VulnCheck at 9.8; CISA scores CVE-2018-5469 at 7.5 and NVD at 9.8; Belden rates CVE-2025-15620 9.3 where NVD gives 8.6. NVD's text for CVE-2018-25237 names "HiSecOS devices", while the Belden bulletin it links lists the Classic Firewall EAGLE and EAGLE One. CVE-2016-2509 and CVE-2016-15058 describe the same Classic password sync issue and both point to CERT/CC VU#507216.
Third, Belden's file names do not always match the bulletin number inside: the PDF NVD links as "BSECV-2018-05" is bulletin BSECV-2017-15, and the one named "BSECV-2016-12" is BSECV-2016-2. Cite the number printed in the document.
How do you harden Hirschmann switches per Hirschmann guidance?
Hirschmann's HiOS user manual Security lists a security setup checklist, and the workarounds in Belden bulletins and CISA advisories add to it. In order:
Put management on its own VLANThe Security manual asks for a VLAN dedicated to device management access, and the HiOS interface reference says HiDiscovery only reaches the device through ports in the management VLAN. Keep that VLAN inside the cell, behind a firewall, never on the office network; CISA's advisories ask users to locate control system networks behind firewalls, isolate them from the business network, and use secure remote access such as VPNs that are kept updated. The Purdue model guide shows where those zones sit. Switch off what you do not useSet HiDiscovery to Off after initial use (or readOnly once the device is in operation), disable HTTP and Telnet, leave SNMPv1/v2 disabled or at least without write access, and keep Modbus TCP, EtherNet/IP, PROFINET, IEC 61850-MMS and the OPC UA server disabled unless the control system uses them. The manual also lists disabling logical access to unused ports and SFP slots. Restrict management to known addressesUse the IP access restriction feature (Restricted Management Access on Classic switches). Belden's workarounds for CVE-2020-6994, CVE-2018-25237 and the libexpat flaws all restrict web access to trusted IP addresses or disable the web server. The manual warns that if no restriction is active, management access is unrestricted for every enabled protocol. Replace default credentials and keysChange or remove the admin/private account, create named accounts with least-privilege roles, load your own HTTPS certificate and SSH host key, and use SNMPv3 with SHA authentication and AES encryption rather than the MD5 and DES delivery state. On Classic switches, disable SNMP password synchronization as BSECV-2016-2 describes. Protect configuration and firmwareEnable configuration encryption, disable loading unencrypted configuration profiles from external memory (ACA), and disable copying software files that lack a valid cryptographic signature, as the manual lists. Update to the fixed version in each line and record itNote the full version string for every device, because one CVE can have six fixed versions across HiOS release lines.
The NIST SP 800-82 guide gives the wider OT security programme these steps fit into, and the small manufacturers guide shows how to start with limited staff.
What does a Hirschmann review of one plant network look like? (worked example)
Synthetic example, not a real site. A packaging plant has two RSP rail switches on HiOS 09.2.01, one MACH4000 backbone switch on Classic 09.0.04, an EAGLE20 firewall on HiSecOS 04.0.01 between the plant and office networks, and one GECKO switch on 02.3.05.
| Observation | Why it matters | Action |
|---|---|---|
| RSP switches on HiOS 09.2.01 | Inside the PSIRT-2 range (since 09.1.00) and below the 09.4.00 OpenSSL fix in BSECV-2023-05; 09.2.01 is not one of the PSIRT-6 fixed versions | Update to 10.5.00 or later, which is at or above the fixes in PSIRT-2, PSIRT-6 and BSECV-2023-05 |
| HiDiscovery On, readWrite, on every HiOS switch | Anyone on the management VLAN can change IP parameters | Set HiDiscovery Off |
| MACH4000 on Classic 09.0.04 with SNMPv1/v2 enabled | Below 09.0.06 for CVE-2016-2509; below 09.1.08 (libexpat) and 09.1.10 (OpenSSL); web flaws in ICSA-18-065-01 have no fix | Update to 09.1.10 or later, disable password sync and SNMPv1/v2, disable HTTP, enable Restricted Management Access |
| EAGLE20 on HiSecOS 04.0.01, web interface reachable from the office network | Below 04.1.00 for CVE-2021-27734 and CVE-2023-7342; 04.0.01 is the version NVD names for CVE-2023-53908; below 04.3.00, 04.4.00 and 04.6.02 for the uClibc, NTP, libexpat and OpenSSL fixes | Update to 04.6.02 or later; allow management only from the engineering workstation |
| GECKO on 02.3.05 | Below 02.4.00 for the OpenSSL fixes | Update to 02.4.00 or later |
Where does passive monitoring and component matching help?
A mirror-port capture shows who talks to the switches' management services without logging in to them. SoftWSP's OT Snapshot reads Zeek and ICSNPP logs from such a capture and builds a host-by-port inventory at connection level, including hosts reaching switches and firewalls on TCP 22, 23, 80 and 443 and UDP 161, and it lists remote-access sessions (SSH, Telnet, RDP, VNC) that cross from outside the private address range. It has no HiDiscovery or HSR decoder and does not read firmware versions or configuration from traffic, so firmware lines come from your asset list. For that list, Device & Firmware Security identifies components and versions and matches them against NVD, CISA KEV, FIRST EPSS and CISA ICS advisories. AI drafts a cited summary, and an engineer reviews it before delivery. For another vendor's network devices, see our Siemens SCALANCE and RUGGEDCOM guide and the Moxa NPort guide.
What are the common pitfalls?
- Recording "HiOS 09" instead of the full version: HiOS fixes are split across 07.1, 08.7, 09.0, 09.3, 10.3 and 10.x lines.
- Assuming a Classic switch is fixed: ICSA-18-065-01 gives no firmware fix for its five web interface flaws, only mitigations.
- Leaving HiDiscovery on with readWrite access after commissioning.
- Relying on NVD CPE matching for Hirschmann CVEs published in 2026, which mostly have no CPE configuration as of 2026-11-21.
- Patching Hirschmann's own CVEs but skipping the OpenSSL, libexpat, uClibc and NTP bulletins, which have their own fixed versions.
- Turning on EtherNet/IP or other industrial protocol services on a switch "for diagnostics" and leaving them reachable, which brings in flaws like CVE-2020-37216.
This guide draws on Belden advisories PSIRT-2 and PSIRT-6, Belden security bulletins BSECV-2016-2, BSECV-2017-15, BSECV-2018-04, BSECV-2019-14, BSECV-2021-07, BSECV-2021-15, BSECV-2021-27, BSECV-2022-26, BSECV-2023-05 and BSECV-2024-02, the Hirschmann HiOS user manual Security and graphical user interface reference for the RSP, CISA ICS advisories ICSA-17-026-02A, ICSA-18-065-01 and ICSA-20-091-01, CERT-FR advisory CERTFR-2021-AVI-377, and NVD records. KEV and EPSS facts are as of 2026-11-21. It is general information, not a substitute for Belden's product-specific security guidance or a current bulletin search for your exact hardware and firmware version.
Put this guide to work
Frequently asked questions
Are Hirschmann or Belden vulnerabilities in the CISA KEV catalog?
No. As of 2026-11-21, the CISA KEV catalog (version 2026.11.20, 1,790 entries) has no entry naming Belden or Hirschmann, and none of the CVEs in this guide is listed, including the third-party OpenSSL, libexpat and uClibc CVEs that Belden maps to its switches and firewalls. FIRST EPSS scores dated 2026-11-20 are low for Hirschmann's own CVEs; the highest is CVE-2018-5469, a Classic switch web login brute-force flaw, at 0.02863. The bundled OpenSSL flaw CVE-2023-0286 scores far higher at 0.61757, so the component fixes in Belden bulletin BSECV-2023-05 deserve early attention.
What is the default password on a Hirschmann HiOS switch?
The HiOS user manual Security for the RSP (HiOS-2A, Release 10.0, 04/2025) lists the delivery-state administrator account as user name admin with password private, noting that the password may have been changed at first login. The same manual says software releases 08.1.00 and higher no longer ship the read-only account user with password public. Hirschmann asks you to create dedicated accounts with least privilege and strong passwords, avoid standard passwords such as private or public, and remove the standard admin account once another administrator account exists.
Should HiDiscovery be switched off on Hirschmann switches?
Yes, after commissioning. The HiOS Security manual says HiDiscovery is enabled in the delivery state and tells you to set it to Off after its initial use, to make the device more immune to unauthorized discovery and manipulation. The HiOS graphical user interface reference explains why: the HiDiscovery software can find Hirschmann devices and assign or change their IP parameters even when they have no valid IP address, and its default access mode is readWrite. If you must keep it on, set it to readOnly once the device is in operation.
Which HiOS versions fix the 2025 and 2026 web server reboot flaws?
Belden advisory PSIRT-2 (2025-10-09) covers CVE-2025-15620, an HTTP GET request that reboots HiOS switches running 09.1.00 or later; the fixes are HiOS 09.4.05 and 10.3.01. Belden advisory PSIRT-6 (2026-09-09) covers CVE-2026-89025, a crafted HTTP(S) request that also forces a reboot; it is fixed in 07.1.12, 08.7.10, 09.0.13, 09.3.03, 10.3.08 and 10.5.00. Both are unauthenticated, so until you update, restrict or disable the web server as Belden's other HiOS bulletins advise.
Why do so many Hirschmann CVEs have 2026 publication dates?
VulnCheck, acting as a CVE Numbering Authority, assigned CVE IDs in April 2026 to flaws that Belden had published years earlier in BSECV bulletins without a CVE, such as the 2018 HiOS web authentication bypass (CVE-2018-25236) and the 2020 HiOS EtherNet/IP denial of service (CVE-2020-37216). As of 2026-11-21, most of these NVD records are Awaiting Analysis or Deferred with no NVD CPE configuration, so a scanner that matches only NVD CPE data will not flag them. Match on the Belden bulletin's product line and version instead.
Sources
- Belden Security Advisory PSIRT-6: HTTP(S) Vulnerability in HiOS (CVE-2026-89025)
- Belden Security Advisory PSIRT-2: Web Interface Vulnerability in HiOS (CVE-2025-15620)
- Belden Security Bulletin BSECV-2023-05: Multiple OpenSSL vulnerabilities in various products
- Belden Security Bulletin BSECV-2022-26: Multiple libexpat vulnerabilities in HiOS, Classic, HiSecOS, Wireless BAT-C2, Lite Managed, Edge
- Belden Security Bulletin BSECV-2021-27: DNS request vulnerability in Firewall Products (CVE-2021-43523)
- Belden Security Bulletin BSECV-2021-15: Multiple NTP vulnerabilities in HiSecOS
- Belden Security Bulletin BSECV-2021-07: HiSecOS Web Server vulnerability allows User Role Privilege Escalation (CVE-2023-7342)
- Belden Security Bulletin BSECV-2024-02: Web Server Authentication Bypass Vulnerability in HiEOS (CVE-2024-14034)
- Belden Security Bulletin BSECV-2019-14: HiOS EtherNet/IP stack vulnerability (CVE-2020-37216)
- Belden Security Bulletin BSECV-2018-04: RADIUS authentication vulnerability (CVE-2018-25237)
- Belden Security Bulletin BSECV-2017-15: Web Server Authentication Bypass Vulnerability in HiOS and HiSecOS (CVE-2018-25236)
- Belden Security Bulletin BSECV-2016-2: Passwords Synchronization with SNMP v1/v2 Communities (CVE-2016-2509)
- Hirschmann: User Manual Security, RSP HiOS-2A, Release 10.0 04/2025
- Hirschmann: RSP HiOS-2A Release 10.3 manual collection (Graphical User Interface reference)
- CISA CSAF: ICSA-20-091-01 Hirschmann Automation and Control HiOS and HiSecOS Products (CVE-2020-6994)
- CISA CSAF: ICSA-18-065-01 Hirschmann Automation and Control GmbH Classic Platform Switches
- CISA CSAF: ICSA-17-026-02A Belden Hirschmann GECKO (Update A)
- CERT-FR: CERTFR-2021-AVI-377, Vulnérabilité dans Belden HiOS et HiSecOS (CVE-2021-27734)
- NVD: CVE-2021-27734 (HiOS and HiSecOS credential change)
- NVD: CVE-2020-9307 (HiOS HSR ring port denial of service)
- NVD: CVE-2023-53908 (HiSecOS NETCONF privilege escalation)
- CISA Known Exploited Vulnerabilities catalog data (kev-data)
- FIRST: Exploit Prediction Scoring System (EPSS) data
About this guide
SoftWSP OT/ICS Desk
Covers the OT/ICS security cluster: 81 guides.

In this cluster