CVE-2019-19707 is a denial-of-service flaw in Moxa EDS-G508E, EDS-G512E and EDS-G516E managed Ethernet switches on firmware 6.0 or lower: PROFINET DCE-RPC endpoint discovery packets, sent without credentials, can take the switch out of service. NVD scores it 7.5. Moxa's fix is a security patch requested from Moxa Technical Support (advisory MPSA-191102, CISA ICSA-19-353-01).
Vulnerability summary
CVSS base score
7.5
High severity
EPSS score (FIRST)
1.3%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2019-19707 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| Moxa EDS-G508E Series | cpe:2.3:o:moxa:eds-g508e_firmware:*:*:*:*:*:*:*:* | Firmware 6.0 or lower (Moxa MPSA-191102, CISA ICSA-19-353-01; NVD CPE up to and including 6.0). Fix: security patch from Moxa Technical Support |
| Moxa EDS-G512E Series | cpe:2.3:o:moxa:eds-g512e_firmware:*:*:*:*:*:*:*:* | Firmware 6.0 or lower (Moxa MPSA-191102, CISA ICSA-19-353-01; NVD CPE up to and including 6.0). Fix: security patch from Moxa Technical Support |
| Moxa EDS-G516E Series | cpe:2.3:o:moxa:eds-g516e_firmware:*:*:*:*:*:*:*:* | Firmware 6.0 or lower (Moxa MPSA-191102, CISA ICSA-19-353-01; NVD CPE up to and including 6.0). Fix: security patch from Moxa Technical Support |
What does this mean for affected devices?
NVD's description reads: "On Moxa EDS-G508E, EDS-G512E, and EDS-G516E devices (with firmware through 6.0), denial of service can occur via PROFINET DCE-RPC endpoint discovery packets." MITRE assigned the CVE, so the CVE record carries no product data (vendor and product "n/a"); the device details come from Moxa and CISA. The record was published on 2019-12-11 (NVD, CVE record).
What goes wrong on the switch?
Moxa's advisory MPSA-191102 (2019-11-20) describes the flaw as "Denial of service by PROFINET DCE-RPC endpoint discovery packets (CWE-400)" and the impact as "the attacker may cause the target device to go out of service." CISA's ICSA-19-353-01 CSAF file (2019-12-19) calls them PROFINET DCE-RPC diagnostic packets and gives the same result. Both class it CWE-400 (uncontrolled resource consumption); NVD's own weakness entry is NVD-CWE-noinfo. Moxa and CISA credit Yuval Ardon and Matan Dobrushin of Otorio.
A switch that goes out of service drops the traffic of every controller and IO device connected through it, so a few packets aimed at the switch can interrupt the process network it carries.
How severe is it?
NVD's Primary score is CVSS v3.1 7.5 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H), with a CVSS v2 score of 7.8. CISA gives the same 7.5 and vector: network reachable, low complexity, no privileges, no user interaction, and an availability impact only. CISA reported no known public exploits specifically targeting it.
Which switches are affected, and what fixes it?
| Product | Affected (Moxa MPSA-191102, CISA ICSA-19-353-01) | Fix |
|---|---|---|
| EDS-G508E Series | Firmware 6.0 or lower | Security patch from Moxa Technical Support |
| EDS-G512E Series | Firmware 6.0 or lower | Security patch from Moxa Technical Support |
| EDS-G516E Series | Firmware 6.0 or lower | Security patch from Moxa Technical Support |
NVD's CPE configuration matches: eds-g508e_firmware, eds-g512e_firmware and eds-g516e_firmware up to and including 6.0. Moxa's solution is "Please contact Moxa Technical Support for the security patch", and CISA repeats it. No numbered public release is named in either advisory, so record the patch build Moxa supplies against each switch.
How do you fix or mitigate it?
Request and install the security patch for every EDS-G508E, EDS-G512E and EDS-G516E on firmware 6.0 or lower. Until it is in, limit which hosts can send DCE-RPC traffic to the switch's own management address, so that only the engineering stations that need PROFINET discovery can reach it. The EDS-G516E also carries the 2020 web interface flaws, including the stack overflow CVE-2020-7007 and the hard-coded password CVE-2020-6981, which affect firmware 5.2 or lower, so check both advisories against the same switch.
Related PROFINET denial-of-service advisories on other vendors' devices: CVE-2019-10936, a Siemens PROFINET UDP flood, and CVE-2021-20986, a Hilscher PROFINET IO device flaw. Our Moxa EDS and EDR guide lists every switch and router CVE with its fix, the PROFINET protocol security guide covers the protocol, and the input handling fix guide covers resource exhaustion flaws (CWE-400).
CVE-2019-19707 is not in the CISA KEV catalog as of 2026-11-22 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.01333, a percentile of 71.9, in the 2026-11-21 dataset (CISA KEV, FIRST EPSS).
Evidence
- NVD (read 2026-11-22): status Modified, published 2019-12-11, last modified 2026-06-17; NVD Primary CVSS v3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H and CVSS v2 7.8; weakness NVD-CWE-noinfo; CPEs eds-g508e, eds-g512e, eds-g516e firmware up to and including 6.0. — NVD
- CVE record (checked 2026-11-22): state PUBLISHED, assigner MITRE, published 2019-12-11; affected vendor/product n/a; no CNA CVSS score. — CVE.org
- CISA CSAF ICSA-19-353-01 version 1 (2019-12-19), read 2026-11-22: EDS-G508E, EDS-G512E, EDS-G516E Series <= 6.0 known affected; CWE-400; PROFINET DCE-RPC diagnostic packets can cause a denial-of-service condition; CVSS v3.0 7.5 AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H; remediation: security patch from Moxa Technical Support; no known public exploits; credit Yuval Ardon and Matan Dobrushin, Otorio. — CISA CSAF ICSA-19-353-01
- Moxa MPSA-191102 V1.0 (2019-11-20), read 2026-11-22: denial of service by PROFINET DCE-RPC endpoint discovery packets (CWE-400), CVE-2019-19707, target device may go out of service; EDS-G508E/G512E/G516E firmware 6.0 or lower; solution: contact Moxa Technical Support for the security patch. — Moxa MPSA-191102
- Not in the CISA KEV catalog, version 2026.11.20 (1,790 entries), checked 2026-11-22. — CISA KEV
- EPSS 0.01333, percentile 0.71860, dataset 2026-11-21, read 2026-11-22. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
How do I fix CVE-2019-19707?
Contact Moxa Technical Support for the security patch for EDS-G508E, EDS-G512E and EDS-G516E switches on firmware 6.0 or lower, as Moxa's advisory MPSA-191102 and CISA ICSA-19-353-01 both say. Neither advisory names a numbered public release, so record the patch build Moxa supplies for each switch.
Does the switch need PROFINET enabled to be affected?
Neither Moxa nor CISA says whether the flaw depends on a PROFINET setting; both list all EDS-G508E, EDS-G512E and EDS-G516E switches on firmware 6.0 or lower as affected. Treat every switch in that range as exposed to DCE-RPC endpoint discovery packets until it is patched.
Why does the CVE record show no product?
MITRE assigned CVE-2019-19707 and its record lists vendor and product as n/a. NVD added CPEs for the EDS-G508E, EDS-G512E and EDS-G516E up to firmware 6.0, and the product and fix details come from Moxa MPSA-191102 and CISA ICSA-19-353-01.
Is CVE-2019-19707 exploited in the wild?
It is not in the CISA KEV catalog as of 2026-11-22 (catalog version 2026.11.20, 1,790 entries), and CISA's advisory reported no known public exploits specifically targeting it. FIRST EPSS gives it 0.01333 (percentile 71.9) in the 2026-11-21 dataset.
Questions about this page?