CVE-2020-7007 is a stack-based buffer overflow in the IEEE 802.1X settings page of the web interface on Moxa EDS-G516E and EDS-510E industrial Ethernet switches running firmware 5.2 or lower. An attacker can crash the switch or execute arbitrary code. NVD scores it 9.8. Moxa offers new firmware for the EDS-G516E; EDS-510E owners get the fix through Moxa Technical Support.
Vulnerability summary
CVSS base score
9.8
Critical severity
EPSS score (FIRST)
2.9%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2020-7007 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| Moxa EDS-G516E Series | cpe:2.3:o:moxa:eds-g516e_firmware:*:*:*:*:*:*:*:* | Firmware 5.2 or lower (Moxa MPSA-190901, CISA ICSA-20-056-04; NVD CPE up to and including 5.2). Fix: new firmware download linked from Moxa's advisory |
| Moxa EDS-510E Series | cpe:2.3:o:moxa:eds-510e_firmware:*:*:*:*:*:*:*:* | Firmware 5.2 or lower (Moxa MPSA-190901, CISA ICSA-20-056-04; NVD CPE up to and including 5.2). Fix: contact Moxa Technical Support |
What does this mean for affected devices?
NVD carries the ICS-CERT description: "In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the attacker may execute arbitrary codes or target the device, causing it to go out of service." ICS-CERT, the CNA, classes it CWE-121 (stack-based buffer overflow); NVD's own weakness entry is CWE-787 (out-of-bounds write). The record was published on 2020-03-24 (NVD, CVE record).
Where is the overflow?
The CVE text does not say, but Moxa's advisory MPSA-190901 (2019-09-25) does: "The web setting page IEEE802.1x setting page is where the vulnerabilities found." So the flaw sits in the switch's web management interface, on the page that configures IEEE 802.1X port authentication, and a successful attack either crashes the switch or runs the attacker's code on it.
How severe is it, and who scored it?
NVD's Primary score is CVSS v3.1 9.8 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H), with a CVSS v2 score of 10.0. CISA's ICSA-20-056-04 CSAF file (2020-02-25) gives the same 9.8 and vector. Neither Moxa's advisory nor the CVE text says whether the attacker must first log in to reach the 802.1X page; the 9.8 vector assumes no privileges. CISA reported no known public exploits specifically targeting these flaws.
Which switches and firmware versions are affected?
| Product | Affected | Fix (Moxa MPSA-190901, CISA ICSA-20-056-04) |
|---|---|---|
| EDS-G516E Series | Firmware 5.2 or lower | New firmware download from Moxa |
| EDS-510E Series | Firmware 5.2 or lower | Contact Moxa Technical Support |
The CVE record names only the EDS-G516E, but Moxa, CISA and NVD's CPE configuration (both eds-g516e_firmware and eds-510e_firmware up to and including 5.2) include the EDS-510E as well. Moxa released its advisory on 2019-09-25; CISA's followed on 2020-02-25, and the CVE record was published on 2020-03-24.
How do you fix or mitigate it?
Update EDS-G516E switches to the firmware Moxa links from the advisory, and ask Moxa Technical Support for the EDS-510E fix. The same advisory covers six other CVEs, including the hard-coded password CVE-2020-6981, a hard-coded cryptographic key (CVE-2020-6979), weak password rules (CVE-2020-6991) and overflows in the syslog, DHCP and PTP setting pages (CVE-2020-6999). Moxa's configuration advice for those also cuts exposure here: enable HTTPS from the Management Interface setting, enable Account Login Failure Lockout, and set a password on configuration files under Configuration File Encryption. Keep the web interface reachable only from a management network, since this flaw and the other setting-page overflows sit there.
Related advisories: CVE-2019-6557, web buffer overflows on the Moxa IKS-G6824A, and CVE-2019-19707, a PROFINET denial of service on the same EDS-G516E family. Our Moxa EDS and EDR guide lists every switch and router CVE with its fix, and the memory corruption fix guide covers this weakness class.
CVE-2020-7007 is not in the CISA KEV catalog as of 2026-11-22 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.02900, a percentile of 87.3, in the 2026-11-21 dataset (CISA KEV, FIRST EPSS).
Evidence
- NVD (read 2026-11-22): status Modified, published 2020-03-24, last modified 2026-06-17; NVD Primary CVSS v3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H and CVSS v2 10.0; CWE-121 (ICS-CERT, Secondary), CWE-787 (NVD, Primary); CPEs eds-g516e_firmware and eds-510e_firmware up to and including 5.2. — NVD
- CVE record (checked 2026-11-22): state PUBLISHED, CNA ICS-CERT, published 2020-03-24; affected 'Moxa EDS-G516E Series firmware, Version 5.2 or lower'; no CNA CVSS score. — CVE.org
- CISA CSAF ICSA-20-056-04 version 1 (2020-02-25), read 2026-11-22: EDS-510E and EDS-G516E firmware <= 5.2 known affected; CWE-121; CVSS v3.0 9.8 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H; remediations: EDS-G516E download new firmware, EDS-510E contact Moxa Technical Support, enable configuration file encryption password, HTTPS and account login failure lockout; no known public exploits; seven CVEs in the advisory. — CISA CSAF ICSA-20-056-04
- Moxa MPSA-190901 V1.0 (2019-09-25), read 2026-11-22: CVE-2020-7007 stack-based buffer overflow (CWE-121), arbitrary code or out of service, found in the IEEE802.1x web setting page; EDS-G516E and EDS-510E firmware 5.2 or lower affected; EDS-G516E: download new firmware; EDS-510E: contact Moxa Technical Support for vulnerabilities 1, 4 and 5. — Moxa MPSA-190901
- Not in the CISA KEV catalog, version 2026.11.20 (1,790 entries), checked 2026-11-22. — CISA KEV
- EPSS 0.02900, percentile 0.87284, dataset 2026-11-21, read 2026-11-22. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which firmware fixes CVE-2020-7007?
Moxa's advisory MPSA-190901 and CISA ICSA-20-056-04 list EDS-G516E and EDS-510E firmware 5.2 or lower as affected. For the EDS-G516E, Moxa links new firmware for download; for the EDS-510E, contact Moxa Technical Support. Neither advisory names the fixed release number, so confirm the running version is above 5.2 after updating.
Does CVE-2020-7007 affect the EDS-510E as well as the EDS-G516E?
Yes. The CVE record text names only the EDS-G516E, but Moxa's advisory, CISA's advisory and NVD's CPE configuration all include the EDS-510E Series on firmware 5.2 or lower.
What can I do before the switch is updated?
Keep the web interface reachable only from a management network, because the flaw is in its IEEE 802.1X setting page. Moxa also advises enabling HTTPS from the Management Interface setting, Account Login Failure Lockout, and a configuration file password, which address the other CVEs in the same advisory.
Is CVE-2020-7007 exploited in the wild?
It is not in the CISA KEV catalog as of 2026-11-22 (catalog version 2026.11.20, 1,790 entries), and CISA's advisory reported no known public exploits specifically targeting it. FIRST EPSS gives it 0.02900 (percentile 87.3) in the 2026-11-21 dataset.
Questions about this page?