Security Advisory

CVE-2011-1919: GE Proficy Plant Applications Overflows

Last updated:
  • CVE-2011-1919

CVE-2011-1919 is a set of stack buffer overflows in four network services of GE Proficy Plant Applications 5.0 and earlier, the manufacturing execution software. Crafted TCP messages can crash the services or possibly run code without logging in. NVD scores it CVSS v2 10.0; GE fixed it in Plant Applications 5.0 SIM 43 and 4.4.1 SIM v10.

Vulnerability summary

CVSS base score

10

Critical severity

EPSS score (FIRST)

4.6%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2011-1919 · Source: NVD

CVSS v3.1 severity rating scale: None 0.0, Low 0.1 to 3.9, Medium 4.0 to 6.9, High 7.0 to 8.9, Critical 9.0 to 10.0
How a CVSS v3.1 base score maps to a severity rating. Source: FIRST CVSS v3.1 specification, section 5.

Affected components

ComponentCPEVersion range
GE Intelligent Platforms Proficy Plant Applicationscpe:2.3:a:ge:intelligent_platforms_proficy_historian:5.0:*:*:*:*:*:*:*Plant Applications 5.0 and earlier (CISA ICSA-11-243-01); NVD's CPEs use a Proficy Historian product name: up to and including 4.4.1, 4.0 and 5.0; fix: 5.0 SIM 43 or 4.4.1 SIM v10

What does this mean for affected devices?

NVD's description reads: "Multiple stack-based buffer overflows in GE Intelligent Platforms Proficy Applications before 4.4.1 SIM 101 and 5.x before 5.0 SIM 43 allow remote attackers to cause a denial of service (daemon crash) or possibly execute arbitrary code via crafted TCP message traffic to (1) PRProficyMgr.exe in Proficy Server Manager, (2) PRGateway.exe in Proficy Server Gateway, (3) PRRDS.exe in Proficy Remote Data Service, or (4) PRLicenseMgr.exe in Proficy Server License Manager." NVD's Primary score is CVSS v2 10.0 (AV:N/AC:L/Au:N/C:C/I:C/A:C) with CWE-119. Its CPE entries name the product as Proficy Historian (up to and including 4.4.1, plus 4.0 and 5.0), although the advisory is about Plant Applications. CERT/CC assigned the id, and the record carries no CNA score (NVD, CVE record).

Which Proficy Plant Applications services are affected?

CISA advisory ICSA-11-243-01 (CSAF), released on 2011-08-31 and last revised on 2013-04-20, lists Proficy Plant Applications 5.0 and earlier. The four services and their TCP ports are Proficy Server Manager (PRProficyMgr.exe, 12293), Proficy Server Gateway (PRGateway.exe, 12294), Proficy Remote Data Service (PRRDS.exe, 12299) and Proficy Server License Manager (PRLicenseMgr.exe, 12401). CISA rates the flaw remotely exploitable and reported no public exploits at the time.

How do I fix CVE-2011-1919?

GE's fix is a Software Improvement Module (SIM): Proficy Plant Applications 5.0 SIM 43 or 4.4.1 SIM v10. NVD's description writes the 4.4.1 fix as "SIM 101"; CISA's advisory names it SIM v10. GE notes that Proficy SIMs are cumulative, so later SIMs carry the fix. GE's own advisory sat behind a support login. Beyond patching:

  • block TCP ports 12293, 12294, 12299 and 12401 at the plant firewall and allow them only from the MES clients that need them;
  • keep Plant Applications servers off the internet and away from the business network, with VPN-only remote access, as CISA's recommended practices say.

The same product has a later license-service flaw, CVE-2012-0231, and the same CISA week brought the Historian Data Archiver overflow CVE-2011-1918. The GE Proficy, CIMPLICITY and Historian guide puts both in the context of every GE and GE Vernova Proficy advisory, and the memory corruption fix guide explains this bug class.

Is CVE-2011-1919 exploited?

CVE-2011-1919 is not in the CISA KEV catalog as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS gives it 0.04597, the 92.43th percentile, in the 2026-11-27 dataset (CISA KEV, FIRST EPSS).

Three signals on every advisory: CVSS says how severe the flaw is, EPSS gives the probability of exploitation in the wild in the next 30 days, and a CISA KEV listing means the flaw has been exploited in the wild
CVSS rates severity, EPSS estimates the likelihood of exploitation, and CISA KEV records exploitation seen in the wild. Source: FIRST EPSS; CISA KEV catalog.
How to fix this class of issueThis advisory's weakness class is Memory corruption. Our practical guide covers how to detect, fix, verify and disclose it: How to fix memory corruption in embedded firmware.
From advisory to verified fix in four steps: read the advisory, find the affected component in the firmware SBOM, apply the fixed version or vendor mitigation, then re-scan the image to confirm the vulnerable version is gone
Read the advisory, find the component in your firmware SBOM, apply the fix, then re-scan to confirm it.

Evidence

  • NVD (read 2026-11-28): status Modified; published 2011-11-02; NVD Primary CVSS v2 10.0 AV:N/AC:L/Au:N/C:C/I:C/A:C; CWE-119; CPE ge intelligent_platforms_proficy_historian up to and including 4.4.1, 4.0, 5.0; description names 4.4.1 SIM 101 and 5.0 SIM 43. — NVD
  • CISA ICSA-11-243-01 (released 2011-08-31, revised 2013-04-20, read 2026-11-28): Plant Applications 5.0 and prior; PRProficyMgr.exe 12293/TCP, PRGateway.exe 12294/TCP, PRRDS.exe 12299/TCP, PRLicenseMgr.exe 12401/TCP; remotely exploitable, no known public exploits; fix 5.0 SIM 43 and 4.4.1 SIM v10; SIMs cumulative; CSAF CWE-119, CVSS v2 10.0. — CISA ICSA-11-243-01
  • CVE record (read 2026-11-28): state PUBLISHED, assigner certcc, published 2011-11-02; affected n/a; no CNA CVSS. — CVE.org
  • Not in the CISA KEV catalog, catalog version 2026.11.27, 1,808 entries, checked 2026-11-28. — CISA KEV
  • EPSS 0.04597, percentile 0.92432, dataset 2026-11-27, read 2026-11-28. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CISA ICSA-11-243-01: GE Proficy Plant Applications Buffer Overflow
  3. CISA ICSA-11-243-01 CSAF (machine-readable advisory)
  4. CVE record CVE-2011-1919 (CVE Services JSON)
  5. CISA KEV
  6. FIRST EPSS

Frequently asked questions

Which Plant Applications SIM fixes CVE-2011-1919?

Proficy Plant Applications 5.0 SIM 43, or 4.4.1 SIM v10 for the older release, according to CISA ICSA-11-243-01. GE says Proficy SIMs are cumulative, so any later SIM also contains the fix.

Which network ports does CVE-2011-1919 reach?

CISA lists TCP 12293 (Server Manager), 12294 (Server Gateway), 12299 (Remote Data Service) and 12401 (License Manager). Restrict these ports to the hosts that need them while the SIM is pending.

Why does NVD list Proficy Historian for this Plant Applications flaw?

NVD's CPE entries for CVE-2011-1919 use the product name intelligent_platforms_proficy_historian, while the description and CISA's advisory describe Proficy Plant Applications. Use CISA's product list for asset matching.

Is CVE-2011-1919 in the CISA KEV catalog?

No, not as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS rates it 0.04597 (92.43rd percentile) in the 2026-11-27 dataset.