Security Advisory

CVE-2012-0231: GE Proficy Plant Applications License Flaw

Last updated:
  • CVE-2012-0231

CVE-2012-0231 is a memory corruption flaw in the Proficy Server License Manager (PRLicenseMgr.exe) of GE Proficy Plant Applications 5.0 and earlier, GE's manufacturing execution software: a crafted TCP session on port 12401 can crash the service or possibly run code. NVD scores it 10.0 (CVSS v2). GE released product updates for versions 5.0 and 4.4.1.

Vulnerability summary

CVSS base score

10

Critical severity

EPSS score (FIRST)

6.9%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2012-0231 · Source: NVD

CVSS v3.1 severity rating scale: None 0.0, Low 0.1 to 3.9, Medium 4.0 to 6.9, High 7.0 to 8.9, Critical 9.0 to 10.0
How a CVSS v3.1 base score maps to a severity rating. Source: FIRST CVSS v3.1 specification, section 5.

Affected components

ComponentCPEVersion range
GE Intelligent Platforms Proficy Plant Applicationscpe:2.3:a:ge:intelligent_platforms_proficy_plant_applications:*:*:*:*:*:*:*:*NVD: up to and including 5.0 (plus 4.2.2, 4.2.3, 4.3.1, 4.4.1, 215.8 entries); CISA ICSA-12-032-02: product updates for supported 5.0 and 4.4.1, patch via GE support for 4.3.1, 4.2.3, 4.2.2 and 215.8

What does this mean for affected devices?

NVD's description reads: "PRLicenseMgr.exe in the Proficy Server License Manager in GE Intelligent Platforms Proficy Plant Applications 5.0 and earlier allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted TCP session on port 12401." NVD's Primary score is CVSS v2 10.0 (AV:N/AC:L/Au:N/C:C/I:C/A:C) with CWE-119; there is no NVD v3 score. NVD's CPE data covers Plant Applications up to and including 5.0 and lists 4.2.2, 4.2.3, 4.3.1, 4.4.1 and 215.8 separately. CERT/CC assigned the record with vendor and product n/a and no CNA score; NVD published it on 2012-03-15 (NVD, CVE record).

What does CISA say?

CISA's advisory 12-032-02 (CSAF), "GE Intelligent Platforms Proficy Plant Applications Memory Corruption Vulnerabilities", lists Proficy Plant Applications 5.0 and earlier and scores the flaw CVSS v2 10.0 with CWE-119, the same as NVD. Plant Applications is GE's plant-floor MES suite, so the license server usually sits on the same network as historians and HMI nodes. GE's own advisory and the updates require a GE user ID and customer service number.

How do I fix it?

GE recommends applying the product updates to the supported Plant Applications versions 5.0 and 4.4.1. Sites on the unsupported versions 4.3.1, 4.2.3, 4.2.2 and 215.8 have to contact GE Intelligent Platforms support to obtain and apply a patch. Proficy SIMs are cumulative, so any later SIM also carries these updates. Until the update is in place, allow TCP port 12401 only from the hosts that need license checks, keep the server behind a firewall, separate from business networks, and never reachable from the internet.

CVE-2012-0229 covers the Data Archiver flaw in GE Proficy Historian from the same month, and CVE-2012-3010 a GE Proficy Real-Time Information Portal overflow. The memory corruption guide explains this bug class, and the OT/ICS security guide for small manufacturers covers MES and SCADA segmentation.

CVE-2012-0231 is not in the CISA KEV catalog as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS gives it 0.0687, a percentile of 94.8, in the 2026-11-27 dataset (CISA KEV, FIRST EPSS).

Three signals on every advisory: CVSS says how severe the flaw is, EPSS gives the probability of exploitation in the wild in the next 30 days, and a CISA KEV listing means the flaw has been exploited in the wild
CVSS rates severity, EPSS estimates the likelihood of exploitation, and CISA KEV records exploitation seen in the wild. Source: FIRST EPSS; CISA KEV catalog.
How to fix this class of issueThis advisory's weakness class is Memory corruption. Our practical guide covers how to detect, fix, verify and disclose it: How to fix memory corruption in embedded firmware.
From advisory to verified fix in four steps: read the advisory, find the affected component in the firmware SBOM, apply the fixed version or vendor mitigation, then re-scan the image to confirm the vulnerable version is gone
Read the advisory, find the component in your firmware SBOM, apply the fix, then re-scan to confirm it.

Evidence

  • NVD (read 2026-11-28): status Modified; published 2012-03-15; NVD Primary CVSS v2 10.0 AV:N/AC:L/Au:N/C:C/I:C/A:C; no v3 metric; CWE-119; CPE intelligent_platforms_proficy_plant_applications up to and including 5.0 plus 4.2.2, 4.2.3, 4.3.1, 4.4.1, 215.8. — NVD
  • CISA ICSA-12-032-02 CSAF (read 2026-11-28): CVE-2012-0231, CWE-119, CVSS v2 10.0 AV:N/AC:L/Au:N/C:C/I:C/A:C; Proficy Plant Applications <=5.0; apply product updates to supported 5.0 and 4.4.1; unsupported 4.3.1, 4.2.3, 4.2.2, 215.8 contact GE support for a patch; GE user ID and customer service number required; SIMs cumulative. — CISA ICSA-12-032-02
  • CVE record (read 2026-11-28): state PUBLISHED, assigner certcc, vendor and product n/a, no CNA CVSS. — CVE.org
  • Not in the CISA KEV catalog, catalog version 2026.11.27, 1,808 entries, checked 2026-11-28. — CISA KEV
  • EPSS 0.06871, percentile 0.94825, dataset 2026-11-27, read 2026-11-28. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CISA ICSA-12-032-02: GE Intelligent Platforms Proficy Plant Applications Memory Corruption Vulnerabilities
  3. CISA ICSA-12-032-02 CSAF (machine-readable advisory)
  4. CVE record CVE-2012-0231 (CVE Services JSON)
  5. CISA KEV
  6. FIRST EPSS

Frequently asked questions

Which Plant Applications versions are affected?

Proficy Plant Applications 5.0 and earlier. GE ships product updates for the supported versions 5.0 and 4.4.1; owners of 4.3.1, 4.2.3, 4.2.2 or 215.8 obtain a patch through GE support.

Which service and port carry the flaw?

The Proficy Server License Manager, PRLicenseMgr.exe, listening on TCP port 12401. A crafted session to that port can crash the service or possibly run code on the server.

What can I do before the update is installed?

Allow TCP 12401 only from the Plant Applications clients and servers that need it, keep the server behind a firewall away from business networks and the internet, and use a VPN for any remote access, as CISA advises.

Is CVE-2012-0231 in the CISA KEV catalog?

No, not as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS rates it 0.0687 (percentile 94.8) in the 2026-11-27 dataset.