Security Advisory

CVE-2011-1918: GE Proficy Historian Data Archiver Overflow

Last updated:
  • CVE-2011-1918

CVE-2011-1918 is a stack-based buffer overflow in the Data Archiver service of GE Proficy Historian, the plant historian that can be installed alongside the iFIX and CIMPLICITY HMI/SCADA packages. Crafted TCP traffic can crash the service or possibly run code on the historian host. NVD scores it 10.0 (CVSS v2). GE fixed it in Historian 4.0 SIM 12, 3.5 SIM 17 and a 3.1 SIM.

Vulnerability summary

CVSS base score

10

Critical severity

EPSS score (FIRST)

6.3%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2011-1918 · Source: NVD

CVSS v3.1 severity rating scale: None 0.0, Low 0.1 to 3.9, Medium 4.0 to 6.9, High 7.0 to 8.9, Critical 9.0 to 10.0
How a CVSS v3.1 base score maps to a severity rating. Source: FIRST CVSS v3.1 specification, section 5.

Affected components

ComponentCPEVersion range
GE Intelligent Platforms Proficy Historian (Data Archiver); Proficy HMI/SCADA iFIX 5.0/5.1 and CIMPLICITY 8.1 when Historian is installedcpe:2.3:a:ge:intelligent_platforms_proficy_historian:*:*:*:*:*:*:*:*NVD: Proficy Historian up to and including 3.5, and 4.0; CISA ICSA-11-243-03A: Historian 4.0 and earlier, iFIX 5.0/5.1 and CIMPLICITY 8.1 with Historian installed. Fixed: Historian 4.0 SIM 12, 3.5 SIM 17, 3.1 SIM IH31_11092015699

What does this mean for affected devices?

NVD's description reads: "Stack-based buffer overflow in the Data Archiver service in GE Intelligent Platforms Proficy Historian before 3.5 SIM 17 and 4.x before 4.0 SIM 12 allows remote attackers to cause a denial of service (daemon crash) or possibly execute arbitrary code via crafted TCP message traffic." NVD's Primary score is CVSS v2 10.0 (AV:N/AC:L/Au:N/C:C/I:C/A:C) with CWE-119, and its CPEs cover Proficy Historian up to and including 3.5 plus 4.0. NVD published the record on 2011-11-02; CERT/CC assigned it with no CNA score (NVD, CVE record).

Which GE products are affected?

CISA advisory ICSA-11-243-03A (CSAF), "GE Intelligent Platforms Proficy Historian Data Archiver Buffer Overflow Vulnerability", lists Proficy Historian 4.0 and earlier, and also Proficy HMI/SCADA CIMPLICITY 8.1 and iFIX 5.0 and 5.1 when Historian is installed alongside them. CISA scores it CVSS v2 10.0 with CWE-119. Two sibling advisories from the same week cover a Proficy Plant Applications overflow (ICSA-11-243-01, CVE-2011-1919) and a Historian Web Administrator cross-site scripting flaw (ICSA-11-243-02, CVE-2011-3320).

How do I fix it?

GE released Software Improvement Modules (SIMs): Proficy Historian 4.0 SIM 12, Proficy Historian 3.5 SIM 17 and, for 3.1, SIM IH31_11092015699.exe. CISA notes that Proficy SIMs are cumulative, so later SIMs include the fix. For iFIX and CIMPLICITY installations GE gives two options: apply the matching Historian SIM if Historian is in use, or uninstall Proficy Historian if it is not. GE's own advisory (KB14493) sits behind a GE support login with a customer service number. Keep historian servers off the internet and behind the plant firewall, as CISA's recommended practices say.

CVE-2012-0229 is a later Data Archiver flaw in the same product, and CVE-2012-3010 covers the GE Proficy Portal. The memory corruption guide explains this class of bug, and the KEV and EPSS prioritization guide shows how to rank old ICS CVEs like this one.

CVE-2011-1918 is not in the CISA KEV catalog as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS gives it 0.0629, a percentile of 94.4, in the 2026-11-27 dataset (CISA KEV, FIRST EPSS).

Three signals on every advisory: CVSS says how severe the flaw is, EPSS gives the probability of exploitation in the wild in the next 30 days, and a CISA KEV listing means the flaw has been exploited in the wild
CVSS rates severity, EPSS estimates the likelihood of exploitation, and CISA KEV records exploitation seen in the wild. Source: FIRST EPSS; CISA KEV catalog.
How to fix this class of issueThis advisory's weakness class is Memory corruption. Our practical guide covers how to detect, fix, verify and disclose it: How to fix memory corruption in embedded firmware.
From advisory to verified fix in four steps: read the advisory, find the affected component in the firmware SBOM, apply the fixed version or vendor mitigation, then re-scan the image to confirm the vulnerable version is gone
Read the advisory, find the component in your firmware SBOM, apply the fix, then re-scan to confirm it.

Evidence

  • NVD (read 2026-11-28): status Modified; published 2011-11-02; NVD Primary CVSS v2 10.0 AV:N/AC:L/Au:N/C:C/I:C/A:C; CWE-119; CPE intelligent_platforms_proficy_historian up to and including 3.5, and 4.0. — NVD
  • CISA ICSA-11-243-03A CSAF (read 2026-11-28): CWE-119, CVSS v2 10.0; Historian <=4.0, CIMPLICITY 8.1 and iFIX 5.0/5.1 if Historian installed; fixes Historian 4.0 SIM 12, 3.5 SIM 17, 3.1 SIM IH31_11092015699.exe; SIMs cumulative; uninstall option; GE KB14493 requires SSO ID and customer service number. — CISA ICSA-11-243-03A
  • CVE record (read 2026-11-28): state PUBLISHED, assigner certcc; affected n/a; no CNA CVSS. — CVE.org
  • Not in the CISA KEV catalog, catalog version 2026.11.27, 1,808 entries, checked 2026-11-28. — CISA KEV
  • EPSS 0.06286, percentile 0.94375, dataset 2026-11-27, read 2026-11-28. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CISA ICSA-11-243-03A: GE Proficy Historian Data Archiver Buffer Overflow
  3. CISA ICSA-11-243-03A CSAF (machine-readable advisory)
  4. CVE record CVE-2011-1918 (CVE Services JSON)
  5. CISA KEV
  6. FIRST EPSS

Frequently asked questions

Which Proficy Historian builds fix CVE-2011-1918?

GE fixed it in Proficy Historian 4.0 SIM 12, Proficy Historian 3.5 SIM 17 and, for version 3.1, SIM IH31_11092015699.exe. Proficy SIMs are cumulative, so any later SIM for the same version also contains the fix.

Are iFIX and CIMPLICITY affected?

Only where Proficy Historian is installed with them. CISA lists CIMPLICITY 8.1 and iFIX 5.0 and 5.1 with Historian installed. Apply the Historian SIM, or uninstall Historian if the site does not use it.

Can I read the GE advisory?

GE published it as KB14493 on its support site, which needs a GE SSO ID and a customer service number. The CISA advisory and its CSAF file repeat the fix versions and the iFIX/CIMPLICITY instructions.

Is CVE-2011-1918 in the CISA KEV catalog?

No, not as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS rates it 0.0629 (percentile 94.4) in the 2026-11-27 dataset.