CVE-2023-0822 is an improper authorization flaw in Delta Electronics DIAEnergie, the industrial energy management software. A user without the right permissions can bypass authorization checks and use privileged functions. NVD scores it 8.8. Versions before v1.9.03.001 are affected; that fix came from Delta on request, and Delta's current advisory sets v1.11.00.022 as the release to run.
Vulnerability summary
CVSS base score
8.8
High severity
EPSS score (FIRST)
0.8%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2023-0822 · Source: NVD

Affected components
| Component | CPE | Version range |
|---|---|---|
| Delta Electronics DIAEnergie | cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:* | Before v1.9.03.001 (CISA ICSA-22-298-06, CVE record, NVD CPE); fix not publicly released, obtained from Delta; install v1.11.00.022 or later (Delta-PCSA-2026-00014) |
What does this mean for affected devices?
CISA added this flaw to ICSA-22-298-06 in its 16 February 2023 update: DIAEnergie "(versions prior to v1.9.03.001) contains improper authorization, which could allow an unauthorized user to bypass authorization and access privileged functionality" (CISA CSAF ICSA-22-298-06). CISA ICS, the CNA, classes it as CWE-285, improper authorization; NVD's own analysis assigns CWE-552, files or directories accessible to external parties. The NVD record was published on 2023-02-17 (NVD).
How severe is CVE-2023-0822?
NVD's Primary score is CVSS v3.1 8.8, CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H, identical to CISA's: a network attacker with a low-privileged account gains high impact on confidentiality, integrity and availability. NVD's CPE data covers versions before 1.9.03.001. CISA credits Michael Heinzl, who also reported the advisory's SQL injections such as CVE-2022-41775.
How do you fix it?
CISA states that Delta "did not publicly release v1.9.01.002, v1.9.02.001, and v1.9.03.001, which address these vulnerabilities" and asks users to contact Delta for them (CVE Program record). Those builds are long superseded. Delta's own advisory Delta-PCSA-2026-00014 of 18 September 2026 covers all DIAEnergie versions before v1.11.00.022 and tells users to contact Delta technical support for v1.11.00.022 or later, so that is the release to install; it also repeats Delta's general advice to keep DIAEnergie off the internet, behind a firewall isolated from the business network, and reachable remotely only through a VPN. DIAEnergie has had later flaws on the same server, among them CVE-2024-43699 and CVE-2024-25574. After updating, review user accounts and their roles, and remove accounts nobody needs.
The Delta Electronics guide puts the DIAEnergie advisories in order with their fix versions. For deciding which DIAEnergie CVEs to handle first when none is in KEV, see the guide to KEV and EPSS vulnerability prioritization.
CVE-2023-0822 is not in the CISA KEV catalog as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS gives it 0.00821, the 54.4th percentile, in the 2026-11-27 dataset (CISA KEV, FIRST EPSS).


Evidence
- NVD (read 2026-11-28): published 2023-02-17; status Modified; NVD Primary CVSS v3.1 8.8 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H; CISA ICS (CNA) Secondary 8.8 same vector; CWE-552 (NVD Primary), CWE-285 (CISA ICS); CPE deltaww diaenergie versionEndExcluding 1.9.03.001. — NVD
- ICSA-22-298-06 (published 2022-11-10, updated 2023-02-16): CVE-2023-0822 improper authorization in DIAEnergie before v1.9.03.001, CWE-285, CVSS v3 8.8; v1.9.01.002, v1.9.02.001 and v1.9.03.001 not publicly released, contact Delta; reported by Michael Heinzl. — CISA CSAF
- CVE record (checked 2026-11-28): PUBLISHED, CNA icscert, published 2023-02-17; DIAEnergie before v1.9.03.001; solution: fix builds not publicly released, contact Delta; credit Michael Heinzl. — CVE Program
- Delta-PCSA-2026-00014 (initial release and last revised 2026-09-18): DIAEnergie versions prior to v1.11.00.022 affected by CVE-2026-78308 to 78313; mitigation: contact Delta technical support to obtain v1.11.00.022 or later; general recommendations: no internet exposure, firewall isolation from the business network, VPN for remote access. — Delta Electronics
- Not in the CISA KEV catalog, catalog version 2026.11.27, 1,808 entries, checked 2026-11-28. — CISA KEV
- EPSS 0.00821, percentile 0.54423, dataset 2026-11-27, read 2026-11-28. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which DIAEnergie versions are affected by CVE-2023-0822?
Versions before v1.9.03.001, per CISA ICSA-22-298-06, the CVE record and NVD's CPE data.
Where do I get the fix?
v1.9.03.001 was not publicly released; CISA asks users to contact Delta. Delta-PCSA-2026-00014 now tells users to obtain v1.11.00.022 or later from Delta technical support.
Why do NVD and CISA list different CWEs?
CISA ICS, the CNA, uses CWE-285 (improper authorization). NVD's analysis uses CWE-552 (files or directories accessible to external parties). The score and vector are the same.
Is CVE-2023-0822 in the CISA KEV catalog?
No, not as of 2026-11-28 (catalog version 2026.11.27). FIRST EPSS gives it 0.00821, the 54.4th percentile, in the 2026-11-27 dataset.
Questions about this page?