Security Advisory

CVE-2024-25574: Delta DIAEnergie SQL Injection

Last updated:
  • CVE-2024-25574

CVE-2024-25574 is an SQL injection (CWE-89) in the GetDIAE_usListParameters function of Delta Electronics DIAEnergie, an industrial energy management system, in versions before v1.10.00.005. NVD scores it 9.8 critical, CISA 8.8. Delta fixed it in DIAEnergie v1.10.00.005, which users request from Delta regional sales or agents.

Vulnerability summary

CVSS base score

9.8

Critical severity

EPSS score (FIRST)

0.9%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2024-25574 · Source: NVD

Affected components

ComponentCPEVersion range
Delta Electronics DIAEnergiecpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*Versions before v1.10.00.005 (CISA ICSA-24-074-12, CVE record, NVD CPE); fixed in v1.10.00.005, available from Delta regional sales or agents

What does this mean for affected devices?

The CVE record for CVE-2024-25574 reads, in full: "SQL injection vulnerability exists in GetDIAE_usListParameters." CISA ICS, the CNA, classifies it as CWE-89 and scores it 8.8 (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). NVD's own Primary CVSS v3.1 score is higher, 9.8 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H): the difference is that NVD assumes no privileges are required. NVD lists no weakness of its own; its CPE configuration covers DIAEnergie versions before 1.10.00.005 (NVD, CVE record).

What else did CISA publish for DIAEnergie in March 2024?

CISA advisory ICSA-24-074-12 of 2024-03-14 lists ten CVEs in DIAEnergie before v1.10.00.005, all reported by Michael Heinzl: six SQL injections (CVE-2024-28891, 25937, 28040, 23975, 23494 and this one), an improper authorization flaw (CVE-2024-28029), two path traversals (CVE-2024-28171 and CVE-2024-25567) and a cross-site scripting flaw (CVE-2024-28045). Delta sells DIAEnergie as an industrial energy management system within its industrial automation software. CISA lists the Critical Manufacturing sector and worldwide deployment, and says exploitation could let an attacker escalate privileges, disclose sensitive information or disrupt system availability. Our Delta Electronics DIAEnergie, PLC and HMI guide tracks the other DIAEnergie advisories, including the later unauthenticated SQL injection CVE-2024-43699.

How do you fix CVE-2024-25574?

Update to DIAEnergie v1.10.00.005. Delta does not offer this version as a public download: CISA says users can request it from Delta Electronics' regional sales or agents (CSAF file). Until the update is in place, follow CISA's recommended practices: keep the DIAEnergie server off the internet, behind a firewall and separated from business networks, and use an up-to-date VPN for remote access. For developers, the input handling fix guide covers SQL injection (CWE-89) and how to verify a fix with parameterised queries.

Is CVE-2024-25574 exploited?

It is absent from the CISA KEV catalog as of 2026-11-26 (catalog version 2026.11.25), and CISA reported no known public exploitation at publication. FIRST EPSS gives 0.00857, the 55.89th percentile, in the 2026-11-25 dataset (FIRST EPSS).

How to fix this class of issueThis advisory's weakness class is SQL injection. Our practical guide covers how to detect, fix, verify and disclose it: How to fix SQL injection, XSS, resource exhaustion and deserialization flaws in embedded firmware.

Evidence

  • NVD: Analyzed; Primary CVSS v3.1 9.8 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H; CISA ICS Secondary 8.8 AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H; CWE-89 from CISA only; CPE deltaww diaenergie before 1.10.00.005; published 2024-04-01; read 2026-11-26. — NVD
  • CVE record: PUBLISHED by CISA ICS 2024-04-01, title Delta Electronics DIAEnergie SQL Injection; affected less than v1.10.00.005; CVSS v3.1 8.8; credit Michael Heinzl. — CVE.org
  • ICSA-24-074-12 (2024-03-14): DIAEnergie < v1.10.00.005; ten CVEs (6 CWE-89, CWE-285, 2 CWE-22, CWE-79); Critical Manufacturing; HQ Taiwan; fix v1.10.00.005 requested from Delta regional sales or agents; no known public exploitation reported. — CISA ICS advisory
  • Delta product page: Products > Industrial Automation > Software > DIAEnergie Industrial Energy Management System; read 2026-11-26. — Delta Electronics
  • Not in the KEV catalog, version 2026.11.25, checked 2026-11-26. — CISA KEV
  • EPSS 0.00857, percentile 0.55889, dataset 2026-11-25. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CVE.org record CVE-2024-25574 (CNA: CISA ICS)
  3. CISA ICS advisory ICSA-24-074-12
  4. CISA CSAF file ICSA-24-074-12
  5. Delta: DIAEnergie Industrial Energy Management System product page
  6. CISA KEV
  7. FIRST EPSS

Frequently asked questions

Which DIAEnergie versions are affected by CVE-2024-25574?

All versions before v1.10.00.005 (per CISA ICSA-24-074-12, the CVE record and NVD's CPE).

Why does NVD score CVE-2024-25574 9.8 when CISA says 8.8?

NVD's vector assumes no privileges are required (PR:N); CISA's vector assumes an attacker needs a low-privileged account (PR:L). Both rate confidentiality, integrity and availability impact as high (per NVD and the CVE record).

How do I get the DIAEnergie fix for CVE-2024-25574?

Delta recommends DIAEnergie v1.10.00.005. Users request this version from Delta Electronics' regional sales or agents (per CISA ICSA-24-074-12).

Is CVE-2024-25574 in the CISA KEV catalog?