Security Advisory

CVE-2022-41667: Operator Terminal Expert DLL Path Traversal

Last updated:
  • CVE-2022-41667

CVE-2022-41667 is a path traversal flaw (CWE-22) in Schneider Electric EcoStruxure Operator Terminal Expert and Pro-face BLUE, the HMI configuration tools for Harmony and Pro-face panels. A user with local privileges could use it to load a malicious DLL and run code on the workstation. NVD scores it 7.8 and Schneider 7.0. V3.3 Service Pack 1 fixes it.

Vulnerability summary

CVSS base score

7.8

High severity

EPSS score (FIRST)

0.3%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2022-41667 · Source: NVD

CVSS v3.1 severity rating scale: None 0.0, Low 0.1 to 3.9, Medium 4.0 to 6.9, High 7.0 to 8.9, Critical 9.0 to 10.0
How a CVSS v3.1 base score maps to a severity rating. Source: FIRST CVSS v3.1 specification, section 5.

Affected components

ComponentCPEVersion range
Schneider Electric EcoStruxure Operator Terminal Expertcpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:*V3.3 Hotfix 1 or prior (NVD: before 3.3, 3.3 and 3.3 HF1); fixed in V3.3 Service Pack 1
Pro-face BLUEcpe:2.3:a:schneider-electric:pro-face_blue:*:*:*:*:*:*:*:*V3.3 Hotfix 1 or prior; fixed in V3.3 Service Pack 1

What does this mean for affected devices?

Schneider's notice SEVD-2022-284-01, published on 11 October 2022, describes "a CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability" "that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code." It sits next to CVE-2022-41666, a missing signature check with the same outcome, and four more flaws: an incorrect project conversion that loads a project from an attacker-controlled network share, a signature check and a path traversal in the SGIUtility component, and an SQL injection during project migration. Noam Moshe and Amir Preminger of Claroty reported all six.

How severe is CVE-2022-41667?

NVD's Primary score is CVSS v3.1 7.8, AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H (NVD). Schneider scores it 7.0 with high attack complexity, AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H, and that 7.0 is the score in the CVE.org record. The CWE-22 label is Schneider's; NVD adds none. The attacker needs a local user account on the engineering workstation.

Which versions are affected and what is the fix?

Affected are Operator Terminal Expert V3.3 Hotfix 1 or prior and Pro-face BLUE V3.3 Hotfix 1 or prior; NVD's configuration matches versions before 3.3, 3.3 itself and 3.3 Hotfix 1. V3.3 Service Pack 1 of each product fixes it, from Schneider's or Pro-face's download pages or through Schneider Electric Software Update (SESU). Schneider asks owners who delay the update to use the software only on a trusted, hardened workstation in a secure network environment.

The Schneider EcoStruxure HMI and SCADA software guide puts this flaw in its Operator Terminal Expert table. The earlier path traversal in the same product, CVE-2020-7497, runs an application at start-up instead. The OT security guide for small manufacturers explains how to keep engineering workstations on a short list of trusted users.

Is CVE-2022-41667 exploited?

It is not in the CISA KEV catalog as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS gives it 0.0030, the 15th percentile, in the 2026-11-27 dataset (CISA KEV, FIRST EPSS).

Three signals on every advisory: CVSS says how severe the flaw is, EPSS gives the probability of exploitation in the wild in the next 30 days, and a CISA KEV listing means the flaw has been exploited in the wild
CVSS rates severity, EPSS estimates the likelihood of exploitation, and CISA KEV records exploitation seen in the wild. Source: FIRST EPSS; CISA KEV catalog.
How to fix this class of issueThis advisory's weakness class is Path traversal. Our practical guide covers how to detect, fix, verify and disclose it: How to fix path traversal in embedded firmware.
From advisory to verified fix in four steps: read the advisory, find the affected component in the firmware SBOM, apply the fixed version or vendor mitigation, then re-scan the image to confirm the vulnerable version is gone
Read the advisory, find the component in your firmware SBOM, apply the fix, then re-scan to confirm it.

Evidence

  • NVD (read 2026-11-28): published 2022-11-04, status Modified; NVD Primary CVSS v3.1 7.8 AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H; Schneider Secondary CVSS v3.1 7.0 AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H; CWE-22 (Schneider, no NVD Primary CWE); CPE ecostruxure_operator_terminal_expert before 3.3, 3.3, 3.3 hf1; pro-face_blue before 3.3, 3.3, 3.3 hf1. — NVD
  • Schneider SEVD-2022-284-01 (11 October 2022, PDF and Schneider CSAF read 2026-11-28): CVE-2022-41667 CWE-22 CVSS v3.1 7.0; sibling CVEs 41666 (CWE-347), 41668 (project conversion from network share), 41669/41670 (SGIUtility), 41671 (SQL injection in project migration); affected V3.3 Hotfix 1 or prior of both products; fix V3.3 Service Pack 1, also via SESU; credit Noam Moshe and Amir Preminger (Claroty). — Schneider Electric
  • CVE.org record (read 2026-11-28): assigner Schneider Electric, CWE-22, CVSS v3.1 7.0 AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H; affected Operator Terminal Expert and Pro-face BLUE V3.3 up to and including Hotfix 1. — CVE.org
  • Not in the CISA KEV catalog, catalog version 2026.11.27, 1,808 entries, checked 2026-11-28. — CISA KEV
  • EPSS 0.00296, percentile 0.14680, dataset 2026-11-27, read 2026-11-28. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. Schneider Electric SEVD-2022-284-01: EcoStruxure Operator Terminal Expert and Pro-face BLUE
  3. CVE.org record (JSON)
  4. CISA KEV
  5. FIRST EPSS

Frequently asked questions

Which version fixes CVE-2022-41667?

V3.3 Service Pack 1 of EcoStruxure Operator Terminal Expert and of Pro-face BLUE. Schneider's SEVD-2022-284-01 lists V3.3 Hotfix 1 and earlier as affected, and the fix also arrives through SESU.

How is it different from CVE-2022-41666?

Both let a local user load a malicious DLL. CVE-2022-41666 is a missing cryptographic signature check (CWE-347); CVE-2022-41667 is a path traversal (CWE-22). They share the same scores and the same fix.

Are the HMI panels themselves affected?

Schneider's notice describes the impact on the Windows workstation where Operator Terminal Expert, Pro-face BLUE or their runtime is installed. It does not list panel firmware as affected.

Is CVE-2022-41667 in the CISA KEV catalog?

No, not as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS rates it 0.0030, the 15th percentile, in the 2026-11-27 dataset.