CVE-2020-7497 is a path traversal flaw (CWE-22) in Schneider Electric's EcoStruxure Operator Terminal Expert HMI configuration software that could cause an arbitrary application to run when the engineering computer starts. NVD scores it 9.8, while CISA and Schneider score it 6.3 because it needs local access and high privileges. Version 3.1 Service Pack 1B fixes it.
Vulnerability summary
CVSS base score
9.8
Critical severity
EPSS score (FIRST)
2.3%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2020-7497 · Source: NVD

Affected components
| Component | CPE | Version range |
|---|---|---|
| Schneider Electric EcoStruxure Operator Terminal Expert (formerly Vijeo XD) | cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:* | Schneider SEVD-2020-133-04 V3.0: 3.1 Service Pack 1A and prior, fixed in 3.1 Service Pack 1B. CISA ICSA-20-142-02 and NVD CPE (up to 3.0, 3.1, 3.1 SP1): 3.1 Service Pack 1 and prior |
What does this mean for affected devices?
The CVE record from Schneider Electric describes "a CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability" in EcoStruxure Operator Terminal Expert, formerly Vijeo XD, "which could cause arbitrary application execution when the computer starts" (CVE.org record). The software runs on the Windows engineering workstation that builds projects for Harmony HMI panels.
Why do the scores differ so much?
NVD's Primary score is CVSS v3.1 9.8, AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, with a CVSS v2 score of 7.5 (NVD). CISA's ICSA-20-142-02, released on 21 May 2020, and Schneider's notice both give CVSS v3.0 6.3, AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H: local access, high attack complexity, high privileges and user interaction. CISA states that the vulnerabilities in its advisory are not exploitable remotely. For triage, the vendor vector matches how the flaw is reached; NVD's network vector is the reason the Schneider EcoStruxure HMI and SCADA software guide warns against relying on one score.
Which versions are affected and what is the fix?
CISA's advisory, from May 2020, lists Operator Terminal Expert 3.1 Service Pack 1 and prior and points to 3.1 Service Pack 1A. Schneider later revised its notice: SEVD-2020-133-04 version 3.0, dated 10 November 2020, lists CVE-2020-7497 as affecting 3.1 Service Pack 1A and prior and says the fix is in 3.1 Service Pack 1B, which supersedes 1A and is also available through the Schneider Electric Software Update (SESU) client. Install 1B, not 1A. CISA's other mitigations still apply: use the software only on a trusted workstation, do not run it with Windows administrator rights, harden the workstation, accept project files only from trusted users and protect them with a project password.
The same advisory covers four project-file flaws, including the SQL injection CVE-2020-7493. On the HMI side, CVE-2020-28221 affects the same product line through Ethernet Download, and CVE-2021-22704 is another path traversal on Harmony panels. The path traversal fix guide covers the root cause.
Is CVE-2020-7497 exploited?
It is not in the CISA KEV catalog as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS gives it 0.02347, the 84.4th percentile, in the 2026-11-27 dataset (CISA KEV, FIRST EPSS).


Evidence
- NVD (read 2026-11-28): published 2020-06-16, status Modified; NVD Primary CVSS v3.1 9.8 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H; NVD Primary CVSS v2 7.5; CWE-22 (NVD and Schneider); CPE ecostruxure_operator_terminal_expert up to including 3.0, 3.1, 3.1 sp1. — NVD
- CISA ICSA-20-142-02 CSAF (read 2026-11-28): released 2020-05-21; CVE-2020-7497 CWE-22 CVSS v3.0 6.3 AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:H; affected 3.1 Service Pack 1 and prior; update to 3.1 SP1A; trusted workstation, no admin rights, project password; not exploitable remotely; sibling CVE-2020-7493..7496. — CISA ICSA-20-142-02
- Schneider SEVD-2020-133-04 V3.0 (10 November 2020, read 2026-11-28): CVE-2020-7495 and CVE-2020-7497 affect 3.1 SP1A and prior; fixes in 3.1 SP1B, which supersedes SP1A; also through SESU; CVSS v3.0 6.3; credited to Fredrik Østrem, Emil Sandstø and Cim Stordal (Cognite). — Schneider Electric
- CVE.org record (read 2026-11-28): assigner Schneider Electric, CWE-22, product 3.1 Service Pack 1 and prior, no CVSS metric in the CNA container. — CVE.org
- Not in the CISA KEV catalog, catalog version 2026.11.27, 1,808 entries, checked 2026-11-28. — CISA KEV
- EPSS 0.02347, percentile 0.84399, dataset 2026-11-27, read 2026-11-28. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Does Service Pack 1A fix CVE-2020-7497?
No. CISA's May 2020 advisory pointed to 3.1 Service Pack 1A, but Schneider's SEVD-2020-133-04 version 3.0 (10 November 2020) lists 1A as affected and places the fix in 3.1 Service Pack 1B, which supersedes 1A.
Can CVE-2020-7497 be exploited over the network?
CISA and Schneider say no: their CVSS v3.0 vector is local, high complexity, high privileges and user interaction (6.3), and CISA notes the advisory's flaws are not exploitable remotely. NVD's Primary CVSS v3.1 vector is network-based and scores 9.8.
What else does ICSA-20-142-02 cover?
Four more Operator Terminal Expert flaws reached by opening a project file: SQL injection CVE-2020-7493, path traversals CVE-2020-7494 and CVE-2020-7495, and argument injection CVE-2020-7496.
Is CVE-2020-7497 in the CISA KEV catalog?
No, not as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS rates it 0.02347, the 84.4th percentile, in the 2026-11-27 dataset.
Questions about this page?