Security Advisory

CVE-2020-7493: Operator Terminal Expert SQL Injection

Last updated:
  • CVE-2020-7493

CVE-2020-7493 is an SQL injection flaw (CWE-89) in Schneider Electric EcoStruxure Operator Terminal Expert, the HMI configuration software formerly called Vijeo XD. Opening a crafted project file could run malicious code on the engineering workstation. NVD scores it 7.8, CISA 8.6 and Schneider 7.7. Install version 3.1 Service Pack 1B.

Vulnerability summary

CVSS base score

7.8

High severity

EPSS score (FIRST)

1.2%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2020-7493 · Source: NVD

CVSS v3.1 severity rating scale: None 0.0, Low 0.1 to 3.9, Medium 4.0 to 6.9, High 7.0 to 8.9, Critical 9.0 to 10.0
How a CVSS v3.1 base score maps to a severity rating. Source: FIRST CVSS v3.1 specification, section 5.

Affected components

ComponentCPEVersion range
Schneider Electric EcoStruxure Operator Terminal Expert (formerly Vijeo XD)cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:*3.1 Service Pack 1 and prior (NVD: up to 3.0, 3.1 and 3.1 SP1); install 3.1 Service Pack 1B

What does this mean for affected devices?

Schneider's notice SEVD-2020-133-04, first released on 12 May 2020 and revised to V3.0 on 10 November 2020, describes "a CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability" "which could cause malicious code execution when opening the project file." Operator Terminal Expert is the configuration software for Schneider's Harmony HMI ranges. Schneider credits Steven Seeley and Chris Anastasio of Incite Team, working with Trend Micro's Zero Day Initiative.

How severe is CVE-2020-7493?

Three scores exist. NVD's Primary score is CVSS v3.1 7.8, AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H, with a Primary CVSS v2 score of 6.8 (NVD). CISA's ICSA-20-142-02 gives CVSS v3 8.6, AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H, assuming a changed scope. Schneider's notice gives CVSS v3.0 7.7, AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H, with high attack complexity. All three need a user to open the file.

Which versions are affected and what is the fix?

Schneider lists Operator Terminal Expert 3.1 Service Pack 1 and prior as affected. CISA's advisory of 21 May 2020 recommended version 3.1 Service Pack 1A. Schneider's later V3.0 notice says "these vulnerabilities are fixed in the EcoStruxure Operator Terminal Expert 3.1 Service Pack 1B" and that SP1A "is now superceded by Service Pack 1B and should be upgraded", so install SP1B. It is available from Schneider's product page and through Schneider Electric Software Update (SESU).

Until then, CISA lists Schneider's workarounds: run the software only on a trusted workstation and not with Windows administrator privileges, harden the workstation, only accept project files from trusted users, manage project files securely and use a project password when saving.

The Schneider EcoStruxure HMI and SCADA software guide compares all Operator Terminal Expert flaws. The same notice covers the path traversal CVE-2020-7497; later project-file flaws in the product are CVE-2023-1049 and CVE-2020-28221. The OT security guide for small manufacturers covers engineering workstation hygiene.

Is CVE-2020-7493 exploited?

It is not in the CISA KEV catalog as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS gives it 0.0117, the 67th percentile, in the 2026-11-27 dataset (CISA KEV, FIRST EPSS).

Three signals on every advisory: CVSS says how severe the flaw is, EPSS gives the probability of exploitation in the wild in the next 30 days, and a CISA KEV listing means the flaw has been exploited in the wild
CVSS rates severity, EPSS estimates the likelihood of exploitation, and CISA KEV records exploitation seen in the wild. Source: FIRST EPSS; CISA KEV catalog.
How to fix this class of issueThis advisory's weakness class is SQL injection. Our practical guide covers how to detect, fix, verify and disclose it: How to fix SQL injection, XSS, resource exhaustion and deserialization flaws in embedded firmware.
From advisory to verified fix in four steps: read the advisory, find the affected component in the firmware SBOM, apply the fixed version or vendor mitigation, then re-scan the image to confirm the vulnerable version is gone
Read the advisory, find the component in your firmware SBOM, apply the fix, then re-scan to confirm it.

Evidence

  • NVD (read 2026-11-28): published 2020-06-16, status Modified; NVD Primary CVSS v3.1 7.8 AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H; NVD Primary CVSS v2 6.8 AV:N/AC:M/Au:N/C:P/I:P/A:P; CWE-89 (NVD and Schneider); CPE ecostruxure_operator_terminal_expert up to and including 3.0, 3.1 and 3.1 sp1. — NVD
  • Schneider SEVD-2020-133-04 V3.0 (12 May 2020, revised 10 November 2020, PDF read 2026-11-28): CVE-2020-7493 affects Operator Terminal Expert 3.1 SP1 and prior; CVSS v3.0 7.7 AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H; remediation: fixed in 3.1 SP1B, SP1A superseded and should be upgraded; available via product page and SESU; credit Steven Seeley and Chris Anastasio (Incite Team) with ZDI. — Schneider Electric
  • CISA ICSA-20-142-02 CSAF (2020-05-21): CWE-89, CVSS v3 8.6 AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H; affected 3.1 SP1 and prior; recommends 3.1 SP1A; workarounds (trusted workstation, no administrator privileges, hardening, trusted project files, project password). — CISA
  • CVE.org record (read 2026-11-28): assigner Schneider Electric, CWE-89, affected EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly Vijeo XD); no CNA CVSS metric. — CVE.org
  • Not in the CISA KEV catalog, catalog version 2026.11.27, 1,808 entries, checked 2026-11-28. — CISA KEV
  • EPSS 0.01165, percentile 0.67139, dataset 2026-11-27, read 2026-11-28. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. Schneider Electric SEVD-2020-133-04 V3.0: EcoStruxure Operator Terminal Expert (Vijeo XD)
  3. CISA ICSA-20-142-02: Schneider Electric EcoStruxure Operator Terminal Expert (CSAF)
  4. CVE.org record (JSON)
  5. CISA KEV
  6. FIRST EPSS

Frequently asked questions

Is 3.1 Service Pack 1A enough?

Install 3.1 Service Pack 1B. CISA's May 2020 advisory recommended SP1A, but Schneider's SEVD-2020-133-04 V3.0 of November 2020 says the fixes are in SP1B and that SP1A is superseded and should be upgraded.

Why are there three different scores?

NVD rates it 7.8 with unchanged scope. CISA rates it 8.6 because it assumes a changed scope. Schneider rates it 7.7 with a changed scope but high attack complexity. All three require a user to open a crafted project file.

What can I do before updating?

Schneider's workarounds, as listed by CISA, are to use the software only on a trusted workstation without Windows administrator privileges, accept project files only from trusted users and protect project files with a project password.

Is CVE-2020-7493 in the CISA KEV catalog?

No, not as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS rates it 0.0117, the 67th percentile, in the 2026-11-27 dataset.