Security Advisory

CVE-2012-0245: ABB Robot Communications Runtime Overflow

Last updated:
  • CVE-2012-0245

CVE-2012-0245 is a set of stack-based buffer overflows in RobNetScanHost.exe, the robot discovery service of ABB Robot Communications Runtime before 5.14.02 on Windows PCs that talk to IRC5 robot controllers. A crafted network packet can crash the service or run code on the PC. NVD scores it 10.0 (CVSS v2). ABB fixed it in version 5.14.02 and published a stand-alone patch.

Vulnerability summary

CVSS base score

10

Critical severity

EPSS score (FIRST)

8.1%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2012-0245 · Source: NVD

CVSS v3.1 severity rating scale: None 0.0, Low 0.1 to 3.9, Medium 4.0 to 6.9, High 7.0 to 8.9, Critical 9.0 to 10.0
How a CVSS v3.1 base score maps to a severity rating. Source: FIRST CVSS v3.1 specification, section 5.

Affected components

ComponentCPEVersion range
ABB Robot Communications Runtime (used by RobotStudio, PC SDK, IRC5 OPC Server)cpe:2.3:a:abb:robot_communications_runtime:*:*:*:*:*:*:*:*ABB SI10227A1: up to and including 5.14.01; fixed in 5.14.02 (RobotStudio, PC SDK, IRC5 OPC Server 5.14.02 and later)
ABB PickMaster 3, PickMaster 5, RobView 5cpe:2.3:a:abb:pickmaster_5:-:*:*:*:*:*:*:*ABB SI10227A1: PickMaster 3 up to 3.3 (fixed 3.40), PickMaster 5 up to 5.13 (fixed 5.20); RobView 5 via patch or updated runtime
ABB WebWare SDK, WebWare Server, Interlink Modulecpe:2.3:a:abb:webware_server:-:*:*:*:*:*:*:*ABB SI10227A1: WebWare SDK and Interlink Module 4.6 through 4.9, WebWare Server 4.6 through 4.91; fix via Robot Communications Runtime 5.14.02 or patch 38599

What does this mean for affected devices?

NVD's description reads: "Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote attackers to execute arbitrary code via a crafted (1) 0xA or (2) 0xE Netscan packet." NVD's Primary score is CVSS v2 10.0 (AV:N/AC:L/Au:N/C:C/I:C/A:C) with CWE-119; there is no NVD v3 score. CERT/CC assigned the record with vendor and product n/a and no CNA score; NVD published it on 2012-03-09 (NVD, CVE record).

What do ABB, CISA and ZDI say?

ABB's advisory SI10227A1 (ABB-VU-DMRO-38599, 2012-02-28) explains that the flaw sits in a component Windows PCs use to communicate with IRC5, IRC5C and IRC5P robot controllers: the RobNetScanHost service overflows when it processes announcements of robot controllers on the subnet. RobotStudio and PickMaster 5 are used to install, program and commission ABB robots, while PickMaster 3, IRC5 OPC Server and WebWare SDK run continuously on factory-network PCs. ABB rates it 10.0 and says the resulting code execution could run with administrator privilege, depending on the installation. The Zero Day Initiative published the original report as ZDI-12-033 on 2012-02-22, credited to Luigi Auriemma, for WebWare Server; ABB then found the other affected products. CISA's advisory ICSA-12-059-01 (CSAF) gives the same product list and CVSS v2 10.0.

How do I fix it?

ABB states that RobotStudio, PC SDK and IRC5 OPC Server 5.14.02 and later do not have the flaw and correct existing installations, as do PickMaster 3 version 3.40 and PickMaster 5 version 5.20. Installing Robot Communications Runtime 5.14.02 from the RobotWare 5.14.02 DVD corrects every product on the PC, and for installations that cannot be upgraded at once ABB offers the service patch "ABB Robot Communications Runtime Patch 38599.msi". ABB notes that the service only runs while a client is active on the PC. CISA recommends firewall rules for port 5512/TCP, so only the robot cell network can reach engineering and OPC PCs.

CVE-2011-5007 (CoDeSys web server on ABB AC500 PLCs) and CVE-2019-18250 (ABB PGIM and Plant Connect) are other ABB advisories on this site. The memory corruption guide covers stack overflows, and the OT/ICS security guide for small manufacturers covers segmenting robot cells.

CVE-2012-0245 is not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS gives it 0.0808, a percentile of 95.6, in the 2026-11-26 dataset (CISA KEV, FIRST EPSS).

Three signals on every advisory: CVSS says how severe the flaw is, EPSS gives the probability of exploitation in the wild in the next 30 days, and a CISA KEV listing means the flaw has been exploited in the wild
CVSS rates severity, EPSS estimates the likelihood of exploitation, and CISA KEV records exploitation seen in the wild. Source: FIRST EPSS; CISA KEV catalog.
How to fix this class of issueThis advisory's weakness class is Memory corruption. Our practical guide covers how to detect, fix, verify and disclose it: How to fix memory corruption in embedded firmware.
From advisory to verified fix in four steps: read the advisory, find the affected component in the firmware SBOM, apply the fixed version or vendor mitigation, then re-scan the image to confirm the vulnerable version is gone
Read the advisory, find the component in your firmware SBOM, apply the fix, then re-scan to confirm it.

Evidence

  • NVD (read 2026-11-27): status Modified; published 2012-03-09; NVD Primary CVSS v2 10.0 AV:N/AC:L/Au:N/C:C/I:C/A:C; no v3 metric; CWE-119; CPE robot_communications_runtime up to and including 5.14.01, plus interlink_module, irc5_opc_server, pc_sdk, pickmaster_3, pickmaster_5, robotstudio, robview_5, webware_sdk, webware_server. — NVD
  • ABB SI10227A1 rev A (2012-02-28, read 2026-11-27): buffer overflow in RobNetScanHost used by Windows PCs communicating with IRC5/IRC5C/IRC5P; affected product versions; CVSS 10.0; code execution possibly with administrator privilege; fixed in 5.14.02 RobotStudio/PC SDK/IRC5 OPC Server, PickMaster 3 v3.40, PickMaster 5 v5.20, Robot Communications Runtime 5.14.02 on RobotWare 5.14.02 DVD; patch 'ABB Robot Communications Runtime Patch 38599.msi'; service only runs while a client is active. — ABB SI10227A1
  • ZDI-12-033 (published 2012-02-22, read 2026-11-27): ABB WebWare RobNetScanHost.exe remote code execution; CVSS 10.0; ZDI-CAN-1260; credit Luigi Auriemma; reported to vendor 2011-10-10. — Zero Day Initiative
  • CISA ICSA-12-059-01 CSAF and web page (read 2026-11-27): CVE-2012-0245, CWE-119, CVSS v2 10.0; product list and versions; port 5512/TCP; firewall rules recommended; ABB issued customer notification and patch. — CISA ICSA-12-059-01
  • CVE record (read 2026-11-27): state PUBLISHED, assigner certcc; no CNA CVSS. — CVE.org
  • Not in the CISA KEV catalog, catalog version 2026.11.25, 1,805 entries, checked 2026-11-27. — CISA KEV
  • EPSS 0.08077, percentile 0.95569, dataset 2026-11-26, read 2026-11-27. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CISA ICSA-12-059-01: ABB Robot Communications Runtime Buffer Overflow
  3. CISA ICSA-12-059-01 CSAF (machine-readable advisory)
  4. ABB SI10227A1: Buffer Overflow in Robot Communications Runtime on Windows
  5. Zero Day Initiative ZDI-12-033
  6. CVE record CVE-2012-0245 (CVE Services JSON)
  7. CISA KEV
  8. FIRST EPSS

Frequently asked questions

Which version fixes CVE-2012-0245?

Robot Communications Runtime 5.14.02. RobotStudio, PC SDK and IRC5 OPC Server 5.14.02 and later, PickMaster 3 version 3.40 and PickMaster 5 version 5.20 include it. ABB also published the stand-alone patch 'ABB Robot Communications Runtime Patch 38599.msi'.

Is the robot controller itself affected?

No. ABB describes the flaw in the Windows PC component used to discover and talk to IRC5, IRC5C and IRC5P controllers. The risk is to engineering, OPC and HMI PCs on the robot network, which in turn can reach the controllers.

What can I do before upgrading?

ABB notes the service only runs while a client such as RobotStudio is active. CISA recommends firewall rules for port 5512/TCP so only the robot cell network can reach those PCs, and keeping the cell off business networks.

Is CVE-2012-0245 in the CISA KEV catalog?

No, not as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS rates it 0.0808 (percentile 95.6) in the 2026-11-26 dataset.