CVE-2024-8957 is an OS command injection in PTZOptics PT30X-SDI and PT30X-NDI cameras before firmware 6.3.40: the NTP server address setting is not validated and runs as part of a command when the NTP client starts. Alone it needs privileges (NVD 7.2); with CVE-2024-8956 it gives unauthenticated root access. CISA KEV lists it. Update to 6.3.40.
Vulnerability summary
CVSS base score
7.2
High severity
EPSS score (FIRST)
24.3%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
Yes
Listed as known exploited
Published
Vulnerability ID: CVE-2024-8957 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| PTZOptics PT30X-SDI | cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:* | Firmware before 6.3.40 (NVD, CVE record); fixed in 6.3.40 |
| PTZOptics PT30X-NDI-xx-G2 | cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:* | Firmware before 6.3.40 (NVD; the CVE record names PT30X-NDI); fixed in 6.3.40 |
What does this mean for affected devices?
VulnCheck, the CNA, published the CVE on 2024-09-17: the camera "does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started", and when chained with CVE-2024-8956 "a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices". NVD and VulnCheck both score it CVSS v3.1 7.2 (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H) with CWE-78. NVD's CPEs are PT30X-SDI and PT30X-NDI-xx-G2 firmware before 6.3.40 (NVD, CVE record, VulnCheck advisory).
Which firmware fixes it?
Firmware 6.3.40, the first release outside the affected range in the CVE record for both the PT30X-SDI and PT30X-NDI. The record and the KEV entry link PTZOptics' firmware changelog, which returned HTTP 404 when we checked on 2026-11-26. GreyNoise reports that the same camera firmware below 6.3.40 runs on HiSilicon Hi3516A V600 boards from more than one manufacturer, that only PTZOptics answered VulnCheck's notification, and that PTZOptics released firmware updates (GreyNoise).
Is CVE-2024-8957 exploited?
Yes. GreyNoise caught attackers chaining it with the settings authentication bypass CVE-2024-8956, which removes the privilege requirement. CISA added both to the KEV catalog on 2024-11-04 with the required action "Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable." (due 2024-11-25; known ransomware campaign use: Unknown); it is still listed as of 2026-11-26 in catalog version 2026.11.25 (CISA KEV). FIRST EPSS gives 0.24349, the 98.34th percentile, in the 2026-11-25 dataset (FIRST EPSS). If an update must wait, take the camera's web and control interfaces off the internet (CISA BOD 23-02 explained). A comparable camera case is the Hikvision injection CVE-2021-36260; the class fix is in how to fix command injection in embedded firmware.
Evidence
- NVD: Analyzed; PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 OS command injection; ntp_addr not validated, command execution when ntp_client starts; chained with CVE-2024-8956 remote unauthenticated; NVD Primary CVSS v3.1 7.2 AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H; VulnCheck Secondary 7.2; CWE-78; CPE pt30x-sdi_firmware and pt30x-ndi-xx-g2_firmware < 6.3.40; published 2024-09-17; read 2026-11-26. — NVD
- CVE record: PUBLISHED, CNA VulnCheck, published 2024-09-17; PT30X-SDI and PT30X-NDI affected < 6.3.40; credit Konstantin Lazarev of GreyNoise. — CVE.org
- VulnCheck advisory repeats the CVE description, before firmware 6.3.40. — VulnCheck
- GreyNoise blog: VHD PTZ camera firmware < 6.3.40 on Hisilicon Hi3516A V600 SoC devices from multiple manufacturers; only PTZOptics responded; firmware updates released; exploitation observed. — GreyNoise
- PTZOptics firmware changelog URL referenced by the CVE record and KEV notes returned HTTP 404 on 2026-11-26. — PTZOptics
- KEV catalog 2026.11.25: dateAdded 2024-11-04, due 2024-11-25, required action apply mitigations per vendor instructions or discontinue, knownRansomwareCampaignUse Unknown, CWE-78; checked 2026-11-26. — CISA KEV
- EPSS 0.24349, percentile 0.98343, dataset 2026-11-25, read 2026-11-26. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which PTZOptics firmware fixes CVE-2024-8957?
Firmware 6.3.40. The CVE record marks PT30X-SDI and PT30X-NDI firmware below 6.3.40 as affected; NVD's CPEs are PT30X-SDI and PT30X-NDI-xx-G2 below 6.3.40 (per the CVE record and NVD).
Why is CVE-2024-8957 only 7.2 if it gives root?
On its own the injection needs high privileges to change the NTP setting, so NVD and VulnCheck score it 7.2. Chained with the authentication bypass CVE-2024-8956, that requirement disappears, which is how it was exploited (per NVD and GreyNoise).
Is CVE-2024-8957 on CISA KEV?
Yes. CISA added it on 2024-11-04 with a due date of 2024-11-25 and the action to apply vendor mitigations or stop using the product; ransomware use is listed as Unknown, as of 2026-11-26 (per CISA KEV).
What is the EPSS score for CVE-2024-8957?
FIRST EPSS gives 0.24349, the 98.34th percentile, in the 2026-11-25 dataset (per FIRST EPSS).
Questions about this page?