Security Advisory

CVE-2024-8956: PTZOptics PT30X Camera Auth Bypass

Last updated:
  • CVE-2024-8956

CVE-2024-8956 is an authentication bypass in PTZOptics PT30X-SDI and PT30X-NDI cameras before firmware 6.3.40: the settings CGI answers requests that carry no Authorization header, so anyone who reaches the camera can read password hashes and change its configuration. NVD scores it 9.1 and CISA KEV lists it as exploited. Update to firmware 6.3.40.

Vulnerability summary

CVSS base score

9.1

Critical severity

EPSS score (FIRST)

2.6%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

Yes

Listed as known exploited

Published

Vulnerability ID: CVE-2024-8956 · Source: NVD

Affected components

ComponentCPEVersion range
PTZOptics PT30X-SDIcpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*Firmware before 6.3.40 (NVD, CVE record); fixed in 6.3.40
PTZOptics PT30X-NDI-xx-G2cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:*Firmware before 6.3.40 (NVD; the CVE record names PT30X-NDI); fixed in 6.3.40

What does this mean for affected devices?

VulnCheck, the CNA, published the CVE on 2024-09-17: PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 does not enforce authentication on its settings CGI when requests are sent without an HTTP Authorization header, so a remote, unauthenticated attacker can leak usernames, password hashes and configuration details and update or overwrite the configuration. NVD and VulnCheck both score it CVSS v3.1 9.1 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N); NVD assigns CWE-287, VulnCheck CWE-306. NVD's CPEs are PT30X-SDI and PT30X-NDI-xx-G2 firmware before 6.3.40 (NVD, CVE record, VulnCheck advisory).

Which firmware fixes it?

The CVE record marks both camera products affected below 6.3.40, so 6.3.40 is the first fixed firmware. The record and the KEV entry point to PTZOptics' firmware changelog page; that page returned HTTP 404 when we checked on 2026-11-26. GreyNoise, whose researcher Konstantin Lazarev is credited with the find, reports that the flaw sits in pan-tilt-zoom camera firmware below 6.3.40 used by more than one manufacturer on HiSilicon Hi3516A V600 boards, that VulnCheck alerted the manufacturers, that only PTZOptics answered, and that PTZOptics released firmware updates (GreyNoise). Cameras from other brands built on the same firmware may need their own vendor's update.

Is CVE-2024-8956 exploited?

Yes. GreyNoise caught exploitation of this flaw chained with the command injection CVE-2024-8957, which gives root code execution. CISA added both to the KEV catalog on 2024-11-04 with the required action "Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable." (due 2024-11-25; known ransomware campaign use: Unknown); it is still listed as of 2026-11-26 in catalog version 2026.11.25 (CISA KEV). FIRST EPSS gives 0.02595, the 86.04th percentile, in the 2026-11-25 dataset (FIRST EPSS). Keep camera control interfaces off the internet (CISA BOD 23-02 explained). A similar exploited camera case is the Hikvision bypass CVE-2017-7921; the class fix is in how to fix authentication bypass in embedded firmware.

How to fix this class of issueThis advisory's weakness class is Authentication bypass. Our practical guide covers how to detect, fix, verify and disclose it: How to fix authentication bypass in embedded firmware.

Evidence

  • NVD: Analyzed; PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 insufficient authentication on the settings CGI when requests lack an HTTP Authorization header; leak usernames, password hashes, configuration; update or overwrite configuration; NVD Primary CVSS v3.1 9.1 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N; VulnCheck Secondary 9.1; CWE-287 (NVD), CWE-306 (VulnCheck); CPE pt30x-sdi_firmware and pt30x-ndi-xx-g2_firmware < 6.3.40; published 2024-09-17; read 2026-11-26. — NVD
  • CVE record: PUBLISHED, CNA VulnCheck, published 2024-09-17; PTZOptics PT30X-SDI and PT30X-NDI affected < 6.3.40; credit Konstantin Lazarev of GreyNoise; references firmware changelog and VulnCheck advisory. — CVE.org
  • VulnCheck advisory repeats the CVE description, before firmware 6.3.40. — VulnCheck
  • GreyNoise blog: affected VHD PTZ camera firmware < 6.3.40 on Hisilicon Hi3516A V600 SoC devices from multiple manufacturers; VulnCheck alerted manufacturers, only PTZOptics responded; manufacturer released firmware updates; exploitation caught by GreyNoise sensors. — GreyNoise
  • PTZOptics firmware changelog URL referenced by the CVE record and KEV notes returned HTTP 404 on 2026-11-26. — PTZOptics
  • KEV catalog 2026.11.25: dateAdded 2024-11-04, due 2024-11-25, required action apply mitigations per vendor instructions or discontinue, knownRansomwareCampaignUse Unknown, CWE-287; checked 2026-11-26. — CISA KEV
  • EPSS 0.02595, percentile 0.86035, dataset 2026-11-25, read 2026-11-26. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CVE.org record CVE-2024-8956 (CNA: VulnCheck)
  3. VulnCheck advisory: PTZOptics insufficient authentication
  4. GreyNoise: zero-day vulnerabilities in live-streaming cameras
  5. CISA KEV
  6. FIRST EPSS

Frequently asked questions

Which PTZOptics cameras are affected by CVE-2024-8956?

The CVE record names the PT30X-SDI and PT30X-NDI with firmware below 6.3.40; NVD's CPEs are PT30X-SDI and PT30X-NDI-xx-G2. CISA's KEV entry calls the product PTZOptics PT30X-SDI/NDI Cameras (per the CVE record, NVD and CISA KEV).

Which firmware fixes CVE-2024-8956?

Firmware 6.3.40. The CVE record marks versions below 6.3.40 as affected, and GreyNoise reports that PTZOptics released firmware updates after VulnCheck's notification (per the CVE record and GreyNoise).

Are other camera brands affected by CVE-2024-8956?

GreyNoise reports the same firmware base in cameras from more than one manufacturer and says only PTZOptics answered VulnCheck. Check your camera vendor's firmware notes if it uses the same platform (per GreyNoise).

How is CVE-2024-8956 related to CVE-2024-8957?

CVE-2024-8956 gives unauthenticated access to camera settings; CVE-2024-8957 is a command injection through the NTP server setting that needs privileges. Chained, they give unauthenticated root code execution; both are on KEV since 2024-11-04 (per NVD and CISA KEV).