Security Advisory

CVE-2025-1316: Edimax IC-7100 Camera Command Injection

Last updated:
  • CVE-2025-1316

CVE-2025-1316 is an OS command injection in the Edimax IC-7100 IP camera that lets a remote attacker run code on the device with crafted requests. It is in CISA KEV. Edimax says the camera was discontinued more than 10 years ago and will receive no patch, so the fix is to retire it.

Vulnerability summary

CVSS base score

9.8

Critical severity

EPSS score (FIRST)

74.5%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

Yes

Listed as known exploited

Published

Vulnerability ID: CVE-2025-1316 · Source: NVD

Affected components

ComponentCPEVersion range
Edimax IC-7100 IP camera (end-of-life)cpe:2.3:o:edimax:ic-7100_firmware:*:*:*:*:*:*:*:*All versions (CISA ICSA-25-063-08, NVD CPE); no fix, Edimax ended firmware maintenance and will not issue a patch

What does this mean for affected devices?

CISA, as the CVE numbering authority, published the issue in ICS advisory ICSA-25-063-08 on 2025-03-04: "Edimax IC-7100 does not properly neutralize requests. An attacker can create specially crafted requests to achieve remote code execution on the device." All versions are affected, the deployment sector is Commercial Facilities, and Akamai SIRT reported it to CISA. At that time CISA wrote that "Edimax has not responded to CISA requests to coordinate the vulnerability" (CISA ICSA-25-063-08). NVD's Primary score is CVSS v3.1 9.8 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H); CISA's CNA scores are 9.8 under v3.1 and 9.3 under CVSS v4, with CWE-78 (NVD, CVE record).

What does Edimax say?

On 2025-03-10 Edimax published a statement: "The Edimax IC-7100 is a legacy product that was discontinued over 10 years ago, and its technical support and firmware maintenance were officially terminated. Due to the unavailability of the development environment and source code, we regret to inform that no security patch or firmware update can be provided for this product." For cameras still in use it asks owners to avoid exposing the device to the internet, restrict external access with a firewall or NAT, change the default admin password at once and check the access logs for unusual activity (Edimax statement). CISA's KEV entry also says users should discontinue product utilization. Our guide to internet-exposed management interfaces covers the network side; the GeoVision devices in CVE-2024-11120 are another end-of-life camera case with the same advice.

Is CVE-2025-1316 exploited?

Yes. CISA added it to KEV on 2025-03-19 as "Edimax IC-7100 IP Camera OS Command Injection Vulnerability", due 2025-04-09, with the required action "Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable." Known ransomware campaign use is Unknown, and the entry is listed as of 2026-11-25 in catalog version 2026.11.24 (CISA KEV). FIRST EPSS gives 0.74482, the 99.50th percentile, in the 2026-11-24 dataset (FIRST EPSS). Hikvision's CVE-2021-36260 is a comparable KEV-listed camera command injection.

How to fix this class of issueThis advisory's weakness class is Command injection. Our practical guide covers how to detect, fix, verify and disclose it: How to fix command injection in embedded firmware.

Evidence

  • NVD (read 2026-11-25): status Analyzed, published 2025-03-05, CNA CISA ICS ([email protected]); NVD Primary CVSS v3.1 9.8 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H; CNA Secondary v3.1 9.8 and v4.0 9.3; CWE-78; CPE edimax ic-7100_firmware (all versions). — NVD
  • CVE record PUBLISHED, CNA icscert; product IC-7100 IP Camera, version All. — CVE.org
  • CISA ICSA-25-063-08 (2025-03-04): all versions affected; Commercial Facilities sector; reported by Akamai SIRT; Edimax has not responded to CISA requests to coordinate. — CISA ICS advisory
  • Edimax statement (2025-03-10): IC-7100 discontinued over 10 years ago, support and firmware maintenance terminated, no security patch or firmware update can be provided; avoid internet exposure, firewall or NAT, change default admin password, monitor access logs. — Edimax
  • KEV catalog 2026.11.24: dateAdded 2025-03-19, due 2025-04-09; product could be EoL/EoS, users should discontinue product utilization; required action quoted; knownRansomwareCampaignUse Unknown; CWE-78. — CISA KEV
  • EPSS 0.74482, percentile 0.99499, dataset 2026-11-24. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. Edimax official statement on CVE-2025-1316
  3. CISA ICS advisory ICSA-25-063-08
  4. CVE.org record CVE-2025-1316 (CNA: CISA ICS)
  5. CISA KEV
  6. FIRST EPSS

Frequently asked questions

Will Edimax release a firmware fix for CVE-2025-1316?

No. Edimax says the IC-7100 was discontinued over 10 years ago, its firmware maintenance has ended and no security patch or firmware update can be provided (per the Edimax statement of 2025-03-10).

What should owners of an Edimax IC-7100 do?

Retire the camera; CISA's KEV entry says users should discontinue product utilization. Until then Edimax advises keeping it off the internet behind a firewall or NAT, changing the default admin password and watching the access logs (per CISA KEV and the Edimax statement).

Which IC-7100 firmware versions are affected by CVE-2025-1316?

All versions (per CISA ICSA-25-063-08 and the CVE record).

Is CVE-2025-1316 exploited in the wild?

Yes. CISA added it to KEV on 2025-03-19 with ransomware use Unknown; it is listed as of 2026-11-25 in catalog version 2026.11.24. FIRST EPSS gives 0.74482 in the 2026-11-24 dataset (per CISA KEV and FIRST EPSS).