Security Advisory

CVE-2023-34347: InfraSuite Device Master Gateway RCE

Last updated:
  • CVE-2023-34347

CVE-2023-34347 is an unauthenticated deserialization flaw in the Device-Gateway service of Delta Electronics InfraSuite Device Master before 1.0.7. A crafted message to the service, which listens on TCP port 3100 by default, can run code on the server with administrator rights. NVD and CISA score it 9.8. Delta fixed it in 1.0.7; install 1.0.10 or later today.

Vulnerability summary

CVSS base score

9.8

Critical severity

EPSS score (FIRST)

1.5%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2023-34347 · Source: NVD

CVSS v3.1 severity rating scale: None 0.0, Low 0.1 to 3.9, Medium 4.0 to 6.9, High 7.0 to 8.9, Critical 9.0 to 10.0
How a CVSS v3.1 base score maps to a severity rating. Source: FIRST CVSS v3.1 specification, section 5.

Affected components

ComponentCPEVersion range
Delta Electronics InfraSuite Device Mastercpe:2.3:a:deltaww:infrasuite_device_master:*:*:*:*:*:*:*:*Before 1.0.7 (CISA ICSA-23-180-01, CVE record, NVD); fixed in 1.0.7; version 1.0.10 or later also covers the later CVE-2023-47207

What does this mean for affected devices?

The CVE record from CISA says that InfraSuite Device Master versions prior to 1.0.7 "contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code." NVD's Primary score and CISA's score are both 9.8, CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. CISA maps it to CWE-502, deserialization of untrusted data; NVD lists no weakness of its own. NVD's configuration covers all versions before 1.0.7 and it published the record on 2023-07-10 (NVD, CVE record).

Trend Micro's Zero Day Initiative published the details as ZDI-23-906: the flaw is in the Device-Gateway service, "which listens on TCP port 3100 by default", authentication is not required, and an attacker "can leverage this vulnerability to execute code in the context of an administrator." ZDI reported it to Delta on 2023-04-06 and the advisory went public on 2023-07-10, credited to Piotr Bazydlo.

What does CISA's advisory cover?

CISA's ICSA-23-180-01, released on 2023-06-29, lists InfraSuite Device Master before 1.0.7, in the Energy sector, deployed worldwide; Delta is based in Taiwan. It has two more CVEs: CVE-2023-30765, improper privilege management that lets a logged-in user change privilege settings (8.8), and CVE-2023-34316, which CISA describes as a way to "bypass the latest" Device Master patch and read file contents (6.5). This was the third round of InfraSuite Device Master fixes in 2023: CVE-2023-1133 and its 12 siblings were fixed in 1.0.5 in March, and CVE-2023-47207, another deserialization flaw found in 1.0.7 itself, needs 1.0.10 or later (ICSA-23-331-01).

How do you fix CVE-2023-34347?

Delta's fix is version 1.0.7, which CISA links as a download from Delta's data center software center. Since 1.0.7 is itself affected by CVE-2023-47207, go straight to 1.0.10 or later. Also:

  • block TCP port 3100 and the other Device Master service ports at the host firewall for everything except the devices and consoles that need them;
  • keep the Device Master server off the internet and on a management network;
  • run the services under an account with no more rights than needed, since the code runs with administrator rights.

The Delta Electronics vulnerabilities guide gathers Delta's OT advisories, and the input handling fix guide covers safe deserialization. An older Device Master deserialization flaw is CVE-2022-41778.

Is CVE-2023-34347 exploited?

CVE-2023-34347 is not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS gives it 0.01543, the 75.28th percentile, in the 2026-11-26 dataset (CISA KEV, FIRST EPSS).

Three signals on every advisory: CVSS says how severe the flaw is, EPSS gives the probability of exploitation in the wild in the next 30 days, and a CISA KEV listing means the flaw has been exploited in the wild
CVSS rates severity, EPSS estimates the likelihood of exploitation, and CISA KEV records exploitation seen in the wild. Source: FIRST EPSS; CISA KEV catalog.
How to fix this class of issueThis advisory's weakness class is Insecure deserialization. Our practical guide covers how to detect, fix, verify and disclose it: How to fix SQL injection, XSS, resource exhaustion and deserialization flaws in embedded firmware.
From advisory to verified fix in four steps: read the advisory, find the affected component in the firmware SBOM, apply the fixed version or vendor mitigation, then re-scan the image to confirm the vulnerable version is gone
Read the advisory, find the component in your firmware SBOM, apply the fix, then re-scan to confirm it.

Evidence

  • NVD (read 2026-11-27): status Modified; published 2023-07-10; NVD Primary CVSS v3.1 9.8 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H; ICS-CERT Secondary 9.8; CWE-502 from ICS-CERT only; CPE deltaww infrasuite_device_master before 1.0.7. — NVD
  • CISA ICSA-23-180-01 CSAF (released 2023-06-29, read 2026-11-27): InfraSuite Device Master <1.0.7; CVE-2023-34347 CWE-502 9.8; siblings CVE-2023-30765 CWE-269 8.8 and CVE-2023-34316 CWE-552 6.5 (bypass of latest patch); fix: update to v1.0.7 (datacenter-softwarecenter.deltaww.com download); Energy, worldwide, HQ Taiwan; credit Piotr Bazydlo (ZDI). — CISA ICSA-23-180-01
  • CVE record (checked 2026-11-27): PUBLISHED, CNA ICS-CERT, published 2023-07-10; CNA CVSS v3.1 9.8, CWE-502; affected Infrasuite Device Master 0 to before v1.0.7; solution update to v1.0.7. — CVE.org
  • CISA ICSA-23-331-01 CSAF (released 2023-11-28, revised 2025-05-06, read 2026-11-27): InfraSuite Device Master <=1.0.7 affected by CVE-2023-46690, 47207, 39226, 47279; Delta recommends v1.0.10 or later. — CISA ICSA-23-331-01
  • ZDI-23-906 (ZDI-CAN-20785, published 2023-07-10, read 2026-11-27): Device-Gateway deserialization RCE, TCP port 3100 by default, no authentication, code runs in the context of an administrator; CVSS 9.8; reported to vendor 2023-04-06; Delta issued an update, refers to ICSA-23-180-01. — Zero Day Initiative ZDI-23-906
  • Not in the CISA KEV catalog, catalog version 2026.11.25, 1,805 entries, checked 2026-11-27. — CISA KEV
  • EPSS 0.01543, percentile 0.75277, dataset 2026-11-26, read 2026-11-27. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CISA ICSA-23-180-01: Delta Electronics InfraSuite Device Master (CSAF)
  3. CISA ICSA-23-180-01 advisory page
  4. CVE.org record CVE-2023-34347
  5. CISA ICSA-23-331-01: Delta Electronics InfraSuite Device Master (CSAF)
  6. Zero Day Initiative ZDI-23-906: InfraSuite Device Master Device-Gateway Deserialization RCE
  7. CISA KEV
  8. FIRST EPSS

Frequently asked questions

Which InfraSuite Device Master versions are affected by CVE-2023-34347?

All versions before 1.0.7, per CISA ICSA-23-180-01, the CVE record and NVD.

Which version should I install?

1.0.7 fixes CVE-2023-34347, but 1.0.7 is affected by the later CVE-2023-47207, for which the fix is 1.0.10 or later. Install 1.0.10 or a later release.

Does an attacker need a login?

No. ZDI states that authentication is not required; the attacker only needs to reach the Device-Gateway service, which listens on TCP port 3100 by default (ZDI-23-906).

Is CVE-2023-34347 in the CISA KEV catalog?

No, not as of 2026-11-27 (catalog version 2026.11.25). FIRST EPSS rates it 0.01543, the 75.28th percentile, in the 2026-11-26 dataset.