CVE-2022-36325 is a DOM-based cross-site scripting flaw in the web interface of many Siemens SCALANCE switches, routers and access points and the RUGGEDCOM RM1224: an authenticated administrator can inject script that runs when the page is rendered. NVD scores it 4.8; Siemens scores it 6.8. Fixes range from V2.0.0 to V7.1.2 by family; the SCALANCE W1748-1 and W1788 M12 access points have no fix intended.
Vulnerability summary
CVSS base score
4.8
Medium severity
EPSS score (FIRST)
1.0%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2022-36325 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| SCALANCE M-800, MUM853-1, MUM856-1, S615 LAN-Router; RUGGEDCOM RM1224 LTE(4G) EU and NAM | cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:* | All versions before V7.1.2; fixed in V7.1.2 (Siemens SSA-710008). NVD's CPE has no version limit |
| SCALANCE SC-600 family (SC622-2C to SC646-2C) | cpe:2.3:o:siemens:scalance_sc-600_firmware:*:*:*:*:*:*:*:* | All versions before V2.3.1; fixed in V2.3.1 (Siemens SSA-710008) |
| SCALANCE W-700 IEEE 802.11ax (WAM763-1, WAM766-1, WUM763-1, WUM766-1) | — | All versions before V2.0.0; fixed in V2.0.0 (Siemens SSA-710008) |
| SCALANCE W-700 IEEE 802.11n family | — | All versions before V6.6.0; fixed in V6.6.0 (Siemens SSA-710008 and SSA-019200, 2026-04-14) |
| SCALANCE XB-200, XC-200, XF-200BA, XP-200 and XR-300WG (incl. SIPLUS NET) | — | All versions before V4.4; fixed in V4.4 (Siemens SSA-710008) |
| SCALANCE XM-400 and XR-500 | — | All versions before V6.6; fixed in V6.6 (Siemens SSA-710008) |
| SCALANCE W1748-1 M12, W1788-1 M12, W1788-2 M12, W1788-2 EEC M12, W1788-2IA M12 | — | All versions; no fix intended as of 2026-11-22 (Siemens SSA-710008) |
What does this mean for affected devices?
NVD carries the Siemens description: affected devices "do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS." NVD's Primary score is CVSS v3.1 4.8 (CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N) with the placeholder NVD-CWE-Other; the Siemens CNA classes it CWE-80 (basic cross-site scripting). The record was published on 2022-08-10 (NVD, CVE record).
How severe is it, and why do the scores differ?
Siemens ProductCERT scores CVE-2022-36325 at CVSS v3.1 6.8 (CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C) in SSA-710008, and CISA's ICSA-22-223-07 CSAF (version 7, 2026-04-16) uses the same vector. NVD scores it as a typical stored XSS: changed scope, low confidentiality and integrity impact, 4.8. Siemens rates all three impacts high with an unchanged scope. Both vectors agree that the attacker needs administrative privileges and that a user has to open the page.
CVE-2022-36325 is not in the CISA KEV catalog as of 2026-11-22 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.01012, the 64.0th percentile, in the 2026-11-21 dataset (CISA KEV, FIRST EPSS).
Which products are affected?
SSA-710008 lists 185 product entries across Siemens' SCALANCE and RUGGEDCOM web-managed lines:
| Family (Siemens wording) | Fixed |
|---|---|
| SCALANCE M-800 (M804PB, M812-1, M816-1, M826-2, M874-2, M874-3, M876-3, M876-4), MUM853-1, MUM856-1, S615 LAN-Router; RUGGEDCOM RM1224 LTE(4G) EU and NAM | V7.1.2 |
| SCALANCE SC-600 (SC622-2C, SC626-2C, SC632-2C, SC636-2C, SC642-2C, SC646-2C) | V2.3.1 |
| SCALANCE W-700 IEEE 802.11ax (WAM763-1, WAM766-1, WUM763-1, WUM766-1 and variants) | V2.0.0 |
| SCALANCE W-700 IEEE 802.11n (W721-1 to W788-2, 49 entries) | V6.6.0 |
| SCALANCE XB-200, XC-200, XF-200BA, XP-200 and XR-300WG (71 entries, incl. SIPLUS NET) | V4.4 |
| SCALANCE XM-400 and XR-500 (26 entries) | V6.6 |
| SCALANCE W1748-1 M12, W1788-1 M12, W1788-2 M12, W1788-2 EEC M12, W1788-2IA M12 | none intended |
The table follows the Siemens CSAF for SSA-710008, version 6 of 2026-04-14 (Siemens SSA-710008 CSAF). Fixes arrived in stages: M-800, MUM-800, RM1224 and S615 in September 2022, W-700 802.11ax in January 2023, XM-400/XR-500 and the XB-200 group in April 2023, and W-700 802.11n in April 2026, when Siemens also published SSA-019200 for W-700 802.11n devices before V6.6.0. NVD's 90 CPE entries give a fixed version only for the six SC-600 models (before 2.3.1); the other 84, including M-800 and S615, have no upper version.
The same advisory covers CVE-2022-36323 (input field code injection by an administrator, Siemens 9.1) and CVE-2022-36324 (TLS renegotiation that bypasses brute-force protection, Siemens 7.5).
How do you fix or mitigate it?
Update each family to the version in the table. For the W1748-1 and W1788 M12 access points, for which Siemens intends no fix, and for any device waiting for an update, Siemens lists two mitigations for all 185 entries: apply the principle of least privilege to the accounts configured on the device, and restrict network access to ports 80/tcp and 443/tcp to trusted IP addresses and personnel. Our SCALANCE and RUGGEDCOM guide covers web management on these devices, and the input handling fix guide explains the class. Other SCALANCE M-800 and web interface flaws include CVE-2024-41976 (M-800 VPN field code execution), CVE-2022-31766 (TCP Event service reboot) and CVE-2023-44318 (hard-coded backup key).
Evidence
- NVD (read 2026-11-22): status Modified; published 2022-08-10; NVD Primary CVSS v3.1 4.8 CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N; Siemens 6.8 Secondary; NVD-CWE-Other (NVD), CWE-80 (Siemens); 90 vulnerable CPE entries, 6 SC-600 entries before 2.3.1 and 84 without version limit (incl. scalance_m-800_firmware and scalance_s615_firmware); references SSA-710008, SSA-019200. — NVD
- Siemens SSA-710008 CSAF version 6 (initial 2022-08-09, current 2026-04-14), read 2026-11-22: CVE-2022-36325 CWE-80, CVSS v3.1 6.8 CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C; 185 known-affected entries; fixes V7.1.2 (M-800, MUM-800, S615, RM1224; 18), V2.3.1 (SC-600; 6), V2.0.0 (W-700 802.11ax; 9), V6.6.0 (W-700 802.11n; 49), V4.4 (XB/XC/XF/XP-200, XR-300WG; 71), V6.6 (XM-400/XR-500; 26); no fix intended for 6 W1748-1/W1788 M12 entries; mitigations: least privilege for accounts, restrict access to 80/tcp and 443/tcp to trusted IP addresses; revision history 2022-09-13, 2023-01-10, 2023-04-11, 2023-10-10, 2026-04-14; also covers CVE-2022-36323 (CWE-74, 9.1) and CVE-2022-36324 (CWE-770, 7.5). — Siemens ProductCERT SSA-710008 (CSAF)
- Siemens SSA-019200 CSAF version 1 (2026-04-14), read 2026-11-22: SCALANCE W-700 IEEE 802.11n devices before V6.6.0 affected by CVE-2022-36325 among others; fix V6.6.0 for 49 entries. — Siemens ProductCERT SSA-019200
- CISA ICSA-22-223-07 CSAF version 7 (initial 2022-08-09, current 2026-04-16), read 2026-11-22: Siemens SCALANCE; CVE-2022-36325 CWE-80, CVSS v3.1 6.8. — CISA CSAF ICSA-22-223-07
- CVE record (checked 2026-11-22): state PUBLISHED, CNA Siemens, published 2022-08-10, updated 2026-04-14; CWE-80; CVSS v3.1 6.8. — CVE.org
- Not in the CISA KEV catalog, version 2026.11.20 (1,790 entries), checked 2026-11-22. — CISA KEV
- EPSS 0.01012, percentile 0.64035, dataset 2026-11-21, read 2026-11-22. — FIRST EPSS

Related advisories
Sources
- NVD
- Siemens ProductCERT SSA-710008: Multiple Web Vulnerabilities in SCALANCE Products
- Siemens ProductCERT SSA-710008 (CSAF, version 6)
- Siemens ProductCERT SSA-019200: Multiple Vulnerabilities in SCALANCE W-700 IEEE 802.11n Devices Before V6.6.0
- CISA CSAF: ICSA-22-223-07 Siemens SCALANCE (machine-readable advisory)
- CVE.org record CVE-2022-36325 (CNA: Siemens)
- CISA KEV
- FIRST EPSS
Frequently asked questions
Which firmware fixes CVE-2022-36325?
Per Siemens SSA-710008 (version 6, 2026-04-14): V7.1.2 for SCALANCE M-800, MUM-800, S615 and RUGGEDCOM RM1224; V2.3.1 for SC-600; V2.0.0 for W-700 802.11ax; V6.6.0 for W-700 802.11n; V4.4 for XB-200, XC-200, XF-200BA, XP-200 and XR-300WG; V6.6 for XM-400 and XR-500.
Which devices have no fix?
The SCALANCE W1748-1 M12, W1788-1 M12, W1788-2 M12, W1788-2 EEC M12 and W1788-2IA M12 access points. Siemens intends no fix and lists least-privilege accounts and restricting ports 80/tcp and 443/tcp to trusted addresses as mitigations.
Who can exploit CVE-2022-36325?
Only an authenticated attacker with administrative privileges, and a user has to load the affected page, according to both the NVD and Siemens vectors. So the attacker must already hold an administrator account on the device; the injected script runs when the affected page is rendered in a user's browser.
Why do NVD and Siemens disagree on the score?
NVD scores a changed-scope XSS with low confidentiality and integrity impact (4.8). Siemens rates confidentiality, integrity and availability high with an unchanged scope (6.8). Both require high privileges and user interaction.
Questions about this page?