CVE-2024-41976 is an input-validation flaw in the VPN configuration of Siemens SCALANCE M-800, MUM-800 and S615 industrial routers and the RUGGEDCOM RM1224: an authenticated attacker who can change specific VPN fields can execute code on the router. NVD scores it 8.8; Siemens scores 7.2 because it requires an administrator account. Firmware V8.1 fixes it on all 24 listed models.
Vulnerability summary
CVSS base score
8.8
High severity
EPSS score (FIRST)
0.8%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2024-41976 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| SCALANCE M-800 routers: M804PB, M812-1 ADSL-Router family, M816-1 ADSL-Router family, M826-2 SHDSL-Router, M874-2, M874-3, M874-3 3G-Router (CN), M876-3, M876-3 (ROK), M876-4, M876-4 (EU), M876-4 (NAM) | cpe:2.3:o:siemens:scalance_m804pb_firmware:*:*:*:*:*:*:*:* | All versions before V8.1; fixed in V8.1 (Siemens SSA-087301) |
| SCALANCE MUM853-1 (A1, B1, EU) and MUM856-1 (A1, B1, CN, EU, RoW) mobile routers | cpe:2.3:o:siemens:scalance_mum856-1_\(eu\)_firmware:*:*:*:*:*:*:*:* | All versions before V8.1; fixed in V8.1 (Siemens SSA-087301) |
| SCALANCE S615 LAN-Router and S615 EEC LAN-Router | cpe:2.3:o:siemens:scalance_s615_lan-router_firmware:*:*:*:*:*:*:*:* | All versions before V8.1; fixed in V8.1 (Siemens SSA-087301) |
| RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) and NAM (6GK6108-4AM00-2DA2) | cpe:2.3:o:siemens:ruggedcom_rm1224_lte\(4g\)_eu_firmware:*:*:*:*:*:*:*:* | All versions before V8.1; fixed in V8.1 (Siemens SSA-087301) |
What does this mean for affected devices?
NVD carries the Siemens description: affected devices "do not properly validate input in specific VPN configuration fields. This could allow an authenticated remote attacker to execute arbitrary code on the device." NVD's Primary score is CVSS v3.1 8.8 (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) with NVD-CWE-noinfo. The Siemens CNA classes it CWE-20 (improper input validation). The record was published on 2024-08-13 (NVD, CVE record).
How severe is CVE-2024-41976?
The two scores differ in one field, the privileges required:
| Scorer | Version | Score | Privileges required |
|---|---|---|---|
| NVD | CVSS v3.1 | 8.8 | low |
| Siemens | CVSS v3.1 | 7.2 (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C) |
high |
| Siemens | CVSS v4.0 | 8.6 | high |
Siemens' vector assumes the attacker already has a high-privileged account; NVD assumes a low-privileged one (Siemens SSA-087301). Industrial routers like these are typically the remote-access, VPN or cellular uplink of a plant or substation network, so code execution on one is a foothold in the OT network. A stolen or shared admin password plus this flaw gives that foothold. Siemens' temporal metric E:P means it rates the exploit code as proof of concept.
CVE-2024-41976 is not in the CISA KEV catalog as of 2026-11-21 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.00768, the 56.4th percentile, in the 2026-11-20 dataset (CISA KEV, FIRST EPSS).
Which routers are affected?
SSA-087301, published on 2024-08-13, lists 24 products, all fixed in V8.1:
| Family (Siemens wording) | Models |
|---|---|
| SCALANCE M-800 | M804PB, M812-1 and M816-1 ADSL-Router families, M826-2 SHDSL-Router, M874-2, M874-3, M874-3 3G-Router (CN), M876-3, M876-3 (ROK), M876-4, M876-4 (EU), M876-4 (NAM) |
| SCALANCE MUM-800 | MUM853-1 (A1, B1, EU), MUM856-1 (A1, B1, CN, EU, RoW) |
| SCALANCE S615 | S615 LAN-Router, S615 EEC LAN-Router |
| RUGGEDCOM RM1224 | LTE(4G) EU, LTE(4G) NAM |
Siemens describes these as industrial routers. The same advisory also fixes CVE-2023-44321, CVE-2024-41977 and CVE-2024-41978 in V8.1. NVD's CPE list matches the 24 models with an upper bound of 8.1 (Siemens SSA-087301 CSAF).
How do you fix or mitigate it?
Update the router firmware to V8.1 or later. SSA-087301 lists no workaround for this CVE beyond Siemens' general advice to protect network access to the device. In practice, that means limiting the web and SSH management interfaces to a management network, giving each administrator a separate account and reviewing who holds administrator rights on each router. V8.1 is well past the V7.2 release that fixed PwnKit CVE-2021-4034 on the same routers, and the unauthenticated TCP Event crash CVE-2022-31766 was fixed earlier, in V7.1.2.
Our SCALANCE and RUGGEDCOM vulnerability guide tracks the M-800 line across its advisories, and the command injection fix guide covers configuration fields that end up in system commands.
Evidence
- NVD (read 2026-11-21): status Analyzed; published 2024-08-13; NVD Primary CVSS v3.1 8.8 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H; Siemens Secondary v3.1 7.2 and v4.0 8.6; CWE NVD-CWE-noinfo (NVD), CWE-20 (Siemens); 26 CPE entries for RM1224, M-800, MUM-800 and S615 firmware before 8.1. — NVD
- Siemens SSA-087301 version 1.0 (published 2024-08-13), read 2026-11-21: SCALANCE M-800, MUM-800 and S615 and RUGGEDCOM RM1224 are industrial routers; CVE-2024-41976: affected devices do not properly validate input in specific VPN configuration fields, allowing an authenticated remote attacker to execute arbitrary code; CVSS v3.1 7.2 CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C, CVSS v4.0 8.6, CWE-20; 24 affected products, all fixed in V8.1; advisory also covers CVE-2023-44321, CVE-2024-41977, CVE-2024-41978. — Siemens ProductCERT SSA-087301
- CVE record (checked 2026-11-21): state PUBLISHED, CNA Siemens, published 2024-08-13; CWE-20; CNA CVSS v3.1 7.2 and v4.0 8.6. — CVE.org
- Not in the CISA KEV catalog, version 2026.11.20 (1,790 entries), checked 2026-11-21. — CISA KEV
- EPSS 0.00768, percentile 0.56447, dataset 2026-11-20, read 2026-11-21. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which firmware fixes CVE-2024-41976?
V8.1 for all 24 listed products: the SCALANCE M-800 and MUM-800 routers, the S615 and S615 EEC LAN routers and the RUGGEDCOM RM1224 LTE(4G) EU and NAM, per Siemens SSA-087301.
Does an attacker need to log in?
Yes. NVD and Siemens both describe an authenticated remote attacker who supplies input to specific VPN configuration fields. Siemens assumes a high-privileged account (PR:H, score 7.2); NVD assumes a low-privileged one (PR:L, score 8.8). Either way, a leaked or shared router password is the realistic way in.
Why does this matter for an OT network?
Siemens describes these devices as industrial routers. Routers like these are typically the remote-access, VPN or cellular uplink of a plant or substation network. Code execution on the router gives an attacker a position inside that network, past the point where traffic is normally filtered.
What can I do before updating?
Siemens lists no specific workaround. Restrict the management interfaces to a management network, remove shared and unused administrator accounts, and change any router passwords that may have been exposed, then schedule the V8.1 update.
Questions about this page?