CVE-2022-31766 is a denial-of-service flaw in the TCP Event service of Siemens SCALANCE M-800, MUM-800, S615 and W-700 802.11ax devices and the RUGGEDCOM RM1224: malformed packets sent to the service, which listens on 26864/tcp by default, make the device reboot. No login is needed. NVD and Siemens both score it 8.6. Firmware V7.1.2 for the routers and V3.0.0 for W-700 fixes it.
Vulnerability summary
CVSS base score
8.6
High severity
EPSS score (FIRST)
1.2%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2022-31766 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| SCALANCE M-800 routers (M804PB, M812-1, M816-1, M826-2, M874-2, M874-3, M876-3, M876-3 (ROK), M876-4, M876-4 (EU), M876-4 (NAM)), SCALANCE MUM853-1 (EU), MUM856-1 (EU, RoW), SCALANCE S615 and S615 EEC LAN-Router | cpe:2.3:o:siemens:scalance_m876-4_firmware:*:*:*:*:*:*:*:* | All versions before V7.1.2; fixed in V7.1.2 (Siemens SSA-697140) |
| RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) and NAM (6GK6108-4AM00-2DA2) | cpe:2.3:o:siemens:ruggedcom_rm1224_firmware:*:*:*:*:*:*:*:* | All versions before V7.1.2; fixed in V7.1.2 (Siemens SSA-697140) |
| SCALANCE W-700 IEEE 802.11ax: WAM763-1, WAM766-1, WAM766-1 (US), WAM766-1 EEC, WAM766-1 EEC (US), WUM763-1 (two order numbers), WUM766-1, WUM766-1 (USA) | cpe:2.3:o:siemens:scalance_wam766-1_firmware:*:*:*:*:*:*:*:* | V1.1.0 and later before V3.0.0; fixed in V3.0.0 (Siemens SSA-697140, corrected 2025-02-11). NVD's CPE has no upper bound |
What does this mean for affected devices?
NVD carries the Siemens description: affected devices "with TCP Event service enabled do not properly handle malformed packets. This could allow an unauthenticated remote attacker to cause a denial of service condition and reboot the device thus possibly affecting other network resources." NVD's Primary score is CVSS v3.1 8.6 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H) with NVD-CWE-noinfo. The Siemens CNA gives the same 8.6 and classes it CWE-20 (improper input validation). The record was published on 2022-10-11 (NVD, CVE record).
How severe is CVE-2022-31766?
The vector needs no privileges and no user interaction. Its scope is changed (S:C), which matches the description's warning that a reboot can affect other network resources: when a router or access point restarts, the network behind it loses its link. The impact is availability only: the advisory describes no code execution or data access. Siemens credits Martin Grubhofer and Michael Messner of Siemens Energy with the report (Siemens SSA-697140). The important condition is that the TCP Event service must be enabled, and Siemens states it is not active by default.
CVE-2022-31766 is not in the CISA KEV catalog as of 2026-11-21 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.01243, the 70.0th percentile, in the 2026-11-20 dataset (CISA KEV, FIRST EPSS).
Which devices are affected?
| Family (Siemens wording) | Affected | Fixed |
|---|---|---|
| SCALANCE M-800 (M804PB, M812-1, M816-1, M826-2, M874-2, M874-3, M876-3, M876-4 variants), MUM853-1 (EU), MUM856-1 (EU, RoW), S615 and S615 EEC | before V7.1.2 | V7.1.2 |
| RUGGEDCOM RM1224 LTE(4G) EU and NAM | before V7.1.2 | V7.1.2 |
| SCALANCE W-700 IEEE 802.11ax: WAM763-1, WAM766-1 (incl. US, EEC), WUM763-1, WUM766-1 (incl. USA) | V1.1.0 up to V3.0.0 | V3.0.0 |
SSA-697140 is at version 1.3, published on 2022-10-11 and last updated on 2025-02-11. The January 2023 update added the W-700 fix; the March 2023 update added the S615 EEC and the M876-4 (6GK5876-4AA10-2BA2) as affected; the February 2025 update corrected the W-700 fix version to V3.0.0. NVD's CPE entries for the W-700 models start at 1.1.0 with no upper bound, so they do not show the fix (Siemens SSA-697140 CSAF).
How do you fix or mitigate it?
Update the M-800, MUM-800, S615 and RM1224 routers to V7.1.2 or later and the W-700 802.11ax devices to V3.0.0 or later. Siemens gives two mitigations for all 29 affected entries:
- deactivate the TCP Event feature, which is not active by default
- restrict access to the TCP Event port, 26864/tcp by default, to trusted networks and client IP addresses
A quick check is whether anything on your network listens to these events at all. If not, switch the service off and the flaw cannot be reached. For later router flaws, see the VPN-field code execution CVE-2024-41976, fixed in V8.1, and PwnKit CVE-2021-4034, fixed on these routers in V7.2. Our SCALANCE and RUGGEDCOM vulnerability guide covers the full range, and the input-handling fix guide explains this class of weakness.
Evidence
- NVD (read 2026-11-21): status Analyzed; published 2022-10-11; NVD Primary CVSS v3.1 8.6 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H; Siemens Secondary 8.6; CWE NVD-CWE-noinfo (NVD), CWE-20 (Siemens); CPE M-800, MUM-800, S615 and RM1224 firmware before 7.1.2; WAM763-1, WAM766-1, WUM763-1, WUM766-1 firmware from 1.1.0 with no upper bound. — NVD
- Siemens SSA-697140 V1.3 (published 2022-10-11, updated 2025-02-11), read 2026-11-21: TCP Event service does not properly handle malformed packets, unauthenticated remote attacker can cause denial of service and reboot; CVSS v3.1 8.6 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C, CWE-20; 29 affected entries; routers fixed in V7.1.2, W-700 802.11ax (V1.1.0 to before V3.0.0) fixed in V3.0.0; mitigations: deactivate TCP Event (not active by default), restrict access to port 26864/tcp; revisions 2023-01-10 (W-700 fix), 2023-03-14 (S615 EEC and M876-4 6GK5876-4AA10-2BA2 added), 2025-02-11 (W-700 fix corrected); credits Martin Grubhofer and Michael Messner (Siemens Energy). — Siemens ProductCERT SSA-697140
- CVE record (checked 2026-11-21): state PUBLISHED, CNA Siemens, published 2022-10-11; CWE-20; CNA CVSS v3.1 8.6. — CVE.org
- Not in the CISA KEV catalog, version 2026.11.20 (1,790 entries), checked 2026-11-21. — CISA KEV
- EPSS 0.01243, percentile 0.69969, dataset 2026-11-20, read 2026-11-21. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which firmware fixes CVE-2022-31766?
V7.1.2 for the SCALANCE M-800, MUM-800, S615 and RUGGEDCOM RM1224 routers, and V3.0.0 for the SCALANCE W-700 IEEE 802.11ax devices, per Siemens SSA-697140. Siemens corrected the W-700 fix version in February 2025, so older notes may show a different number.
Is my device exposed if I never enabled TCP Event?
Siemens says the TCP Event service is not active by default, and the flaw only affects devices with the service enabled. If the feature is off, the flaw cannot be reached. Confirm the setting on each device, because configurations get copied between units.
What port does the TCP Event service use?
26864/tcp by default, according to Siemens. If the service is needed, restrict that port to trusted networks and the specific client IP addresses that collect the events, as SSA-697140 recommends.
Can CVE-2022-31766 be used to take over the device?
Neither NVD nor Siemens describes code execution or data access. The impact is a denial of service: the device reboots. Because these are routers and access points, that reboot can also cut off the network segment behind them, which matches the changed scope (S:C) in the score.