Security Advisory

CVE-2021-37209: RUGGEDCOM ROS Weak SSH Ciphers

Last updated:
  • CVE-2021-37209

CVE-2021-37209 is a default configuration weakness in Siemens RUGGEDCOM ROS: the SSH server offers weak ciphers out of the box, so an attacker in a man-in-the-middle position could read and modify management sessions. Siemens scores it 6.7; NVD's Primary score is the older CVSS v2 4.0. Fixed in ROS V4.3.8 for V4.x devices and V5.7.0 for V5.x devices.

Vulnerability summary

CVSS base score

4

Medium severity

EPSS score (FIRST)

0.4%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2021-37209 · Source: NVD

Affected components

ComponentCPEVersion range
RUGGEDCOM ROS V4.x devices (i800 to i803, M969, M2100, M2200, RMC30, RP110, RS400 to RS8000 families, RSG2100, RSG2200 and V4.X lines of RMC8388, RSG2288, RSG2300, RSG2488, RSG920P and others)cpe:2.3:o:siemens:ruggedcom_ros:*:*:*:*:*:*:*:*All versions before V4.3.8; fixed in V4.3.8 (Siemens SSA-764417). NVD's CPE has no version limit
RUGGEDCOM ROS V5.x devices (RSG907R, RSG908C, RSG909R, RSG910C, RSL910, RST916C, RST916P, RST2228, RST2228P and V5.X lines of RMC8388, RS416v2, RSG2288, RSG2300, RSG2488, RSG920P and others)cpe:2.3:o:siemens:ruggedcom_ros:*:*:*:*:*:*:*:*All versions before V5.7.0; fixed in V5.7.0 (Siemens SSA-764417). NVD's CPE has no version limit

What does this mean for affected devices?

NVD carries the Siemens description for 74 RUGGEDCOM ROS models: "The SSH server on affected devices is configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device." The only metric NVD labels Primary is CVSS v2 4.0 (AV:N/AC:L/Au:S/C:P/I:N/A:N). NVD's CVSS v3.1 score of 6.5 (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N) and the Siemens score of 6.7 are both labelled Secondary. NVD classes it CWE-311 (missing encryption of sensitive data); the Siemens CNA classes it CWE-326 (inadequate encryption strength). The record was published on 2022-03-08 (NVD, CVE record).

How severe is it?

Siemens ProductCERT scores CVE-2021-37209 at CVSS v3.1 6.7 (CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H/E:P/RL:U/RC:C) in SSA-764417: the attacker needs to be on the adjacent network, in the path between an SSH client and the switch, and needs a legitimate user to connect. NVD's v3.1 analysis instead assumes a network attacker with low privileges and rates only confidentiality. CISA's ICSA-22-069-01 CSAF (version 10, 2025-08-12) carries the Siemens 6.7 vector. Siemens credits Michael Messner of Siemens Energy with the report.

CVE-2021-37209 is not in the CISA KEV catalog as of 2026-11-22 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.00378, the 32.4th percentile, in the 2026-11-21 dataset (CISA KEV, FIRST EPSS).

Which devices are affected?

ROS line (Siemens wording) Affected Fixed
ROS V4.x devices: i800, i801, i802, i803, M969, M2100, M2200, RMC30, RP110, RS400, RS401, RS416, RS416P, RS900, RS900G, RS900GP, RS900L, RS900W, RS900M variants, RS910, RS910L, RS910W, RS920L, RS920W, RS930L, RS930W, RS940G, RS969, RS1600, RS1600F, RS1600T, RS8000, RS8000A, RS8000H, RS8000T, RSG2100, RSG2100P, RSG2200 and the V4.X lines of RMC8388, RS416v2, RS416Pv2, RS900 (32M), RS900G (32M), RSG2100 (32M), RSG2100P (32M), RSG2288, RSG2300, RSG2300P, RSG2488, RSG920P before V4.3.8 V4.3.8
ROS V5.x devices: RSG907R, RSG908C, RSG909R, RSG910C, RSL910, RST916C, RST916P, RST2228, RST2228P and the V5.X lines of RMC8388, RS416v2, RS416Pv2, RS900 (32M), RS900G (32M), RSG2100 (32M), RSG2100P (32M), RSG2288, RSG2300, RSG2300P, RSG2488, RSG920P before V5.7.0 V5.7.0

The table follows the Siemens CSAF for SSA-764417, version 10 of 2025-08-12, which lists 53 V4.x and 21 V5.x entries (Siemens SSA-764417 CSAF). The advisory changed a lot after publication: in June 2022 Siemens corrected the title, description, CVSS vector and CWE and said no fix was available; the V5.x fix followed in December 2022 and the V4.x fix in March 2023; later revisions added the RS416v2 and RS416Pv2 V4.X lines and the RSG2100P (32M). NVD has a single CPE entry, ruggedcom_ros with no version limit, so it cannot tell a fixed device from an unfixed one.

How do you fix or mitigate it?

Update V4.x devices to ROS V4.3.8 and V5.x devices to ROS V5.7.0 or later. Until then Siemens lists two mitigations for all 74 entries: configure the SSH clients to use the strong key exchange methods the ROS SSH server supports (ecdh-sha2-nistp256, ecdh-sha2-nistp384 or ecdh-sha2-nistp521), and add only trusted SSH client public keys to ROS and allow access to those clients only. Keeping SSH management on a separate, trusted network makes the man-in-the-middle position harder to reach. Our SCALANCE and RUGGEDCOM guide covers ROS management services, and the weak cryptography fix guide explains the class. Other ROS flaws include CVE-2021-31895 (DHCP client overflow), CVE-2023-24845 (mirror port injection) and CVE-2017-12736 (RCDP writable after commissioning).

How to fix this class of issueNo dedicated SoftWSP guide covers this weakness class; the fix is usually the vendor patch or firmware update referenced above. Our related guide explains how to plan and verify it: NIST SP 800-40 Rev. 4: enterprise patch management planning, explained.

Evidence

  • NVD (read 2026-11-22): status Modified; published 2022-03-08; NVD Primary CVSS v2 4.0 AV:N/AC:L/Au:S/C:P/I:N/A:N; NVD CVSS v3.1 6.5 and Siemens CVSS v3.1 6.7 both Secondary; CWE-311 (NVD), CWE-326 (Siemens); one CPE, cpe:2.3:o:siemens:ruggedcom_ros without version limit; reference SSA-764417. — NVD
  • Siemens SSA-764417 CSAF version 10 (initial 2022-03-08, current 2025-08-12), read 2026-11-22: CWE-326, CVSS v3.1 6.7 CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H/E:P/RL:U/RC:C; 74 known-affected entries; fixes V4.3.8 (53 entries) and V5.7.0 (21); mitigations: configure SSH clients to use ecdh-sha2-nistp256/384/521 key exchange, add only trusted SSH client public keys; revision history including 2022-06-14 correction of title, description, vector and CWE, 2022-12-13 V5.X fix, 2023-03-14 V4.X fix. — Siemens ProductCERT SSA-764417 (CSAF)
  • Siemens SSA-764417 text edition, read 2026-11-22: acknowledges Michael Messner from Siemens Energy for reporting the vulnerability. — Siemens ProductCERT SSA-764417
  • CISA ICSA-22-069-01 CSAF version 10 (initial 2022-03-08, current 2025-08-12), read 2026-11-22: Siemens RUGGEDCOM Devices; CVE-2021-37209 CWE-326, CVSS v3.1 6.7. — CISA CSAF ICSA-22-069-01
  • CVE record (checked 2026-11-22): state PUBLISHED, CNA Siemens, published 2022-03-08, updated 2025-08-12; CWE-326; CVSS v3.1 6.7; 74 affected entries. — CVE.org
  • Not in the CISA KEV catalog, version 2026.11.20 (1,790 entries), checked 2026-11-22. — CISA KEV
  • EPSS 0.00378, percentile 0.32446, dataset 2026-11-21, read 2026-11-22. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. Siemens ProductCERT SSA-764417: Weak Encryption Vulnerability in RUGGEDCOM ROS Devices
  3. Siemens ProductCERT SSA-764417 (CSAF, version 10)
  4. CISA CSAF: ICSA-22-069-01 Siemens RUGGEDCOM Devices (machine-readable advisory)
  5. CVE.org record CVE-2021-37209 (CNA: Siemens)
  6. CISA KEV
  7. FIRST EPSS

Frequently asked questions

Which ROS version fixes CVE-2021-37209?

ROS V4.3.8 for devices on the V4.x line and ROS V5.7.0 for devices on the V5.x line, per the Siemens SSA-764417 CSAF (version 10, 2025-08-12). Siemens added the V5.x fix in December 2022 and the V4.x fix in March 2023.

What can I do before updating?

Siemens recommends configuring SSH clients to use the strong key exchange methods ecdh-sha2-nistp256, ecdh-sha2-nistp384 or ecdh-sha2-nistp521, which the ROS SSH server supports, and adding only trusted SSH client public keys to ROS so that only those clients get access.

Why is the NVD Primary score only 4.0?

For this record the only metric NVD labels Primary is CVSS v2 4.0. NVD's CVSS v3.1 score of 6.5 and the Siemens CVSS v3.1 score of 6.7 are both shown as Secondary, and the two v3.1 vectors disagree on attack vector, privileges and impact.

How do I know which ROS line my device runs?

Siemens lists several models twice, for example RSG2288 V4.X and RSG2288 V5.X, because the same hardware can run either line. Check the firmware version on the device: below 5.0 it needs V4.3.8, on 5.x it needs V5.7.0.