CVE-2017-12736 means the RUGGEDCOM Discovery Protocol (RCDP) can still write to RUGGEDCOM ROS devices and some SCALANCE X switches after commissioning, so an attacker on the same layer 2 network can perform administrative actions without logging in. Siemens scores it 8.8; NVD's Primary score is the older CVSS v2 5.8. Fixed in ROS V4.3.4 and V5.0.1; turning RCDP off fully mitigates it.
Vulnerability summary
CVSS base score
5.8
Medium severity
EPSS score (FIRST)
1.1%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2017-12736 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| RUGGEDCOM ROS V4.x devices (i800 to i803, M969, M2100, M2200, RMC30, RP110, RS400 to RS8000, RSG2100 to RSG2488 families, incl. NC variants) | cpe:2.3:o:siemens:ruggedcom_ros:*:*:*:*:*:*:*:* | All versions before V4.3.4; fixed in V4.3.4 (Siemens SSA-856721) |
| RUGGEDCOM ROS V5.x devices (RSG907R, RSG908C, RSG909R, RSG910C, RSL910, RST916C, RST916P, RST2228, RST2228P and V5.X lines of RMC8388, RS416v2, RSG2288, RSG2300, RSG2488 and others) | cpe:2.3:o:siemens:ruggedcom_ros:*:*:*:*:*:*:*:* | All versions before V5.0.1; fixed in V5.0.1 (Siemens SSA-856721) |
| SCALANCE XB-200, XC-200, XP-200, XF-200 and XR-300WG switches | cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:* | V3.0 up to (excluding) V3.0.2; fixed in V3.0.2 (Siemens SSA-856721). NVD's CPE starts at 3.0 with no upper bound |
| SCALANCE XM-400 and XR-500 switches | cpe:2.3:o:siemens:scalance_xm-400_firmware:*:*:*:*:*:*:*:* | V6.1.0 up to (excluding) V6.1.1; fixed in V6.1.1 (Siemens SSA-856721 CSAF V4). NVD's CPE starts at 6.1 with no upper bound |
What does this mean for affected devices?
NVD carries the Siemens description: "After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain conditions. This could allow an attacker located in the adjacent network of the targeted device to perform unauthorized administrative actions." The only metric NVD labels Primary is CVSS v2 5.8 (AV:A/AC:L/Au:N/C:P/I:P/A:P). NVD's own CVSS v3.0 score of 8.8 and the Siemens CVSS v3.1 score of 8.8 (CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H) are both labelled Secondary. NVD classes it CWE-665 (improper initialization); the Siemens CNA classes it CWE-1188 (initialization of a resource with an insecure default). The record was published on 2017-12-26 (NVD, CVE record).
What is RCDP and why does it matter after commissioning?
RCDP, the RUGGEDCOM Discovery Protocol, is a layer 2 protocol that RUGGEDCOM tools use to find and set up devices on a segment. Siemens ProductCERT SSA-856721 says it "is not properly configured after commissioning of RUGGEDCOM ROS based devices and some SCALANCE X switch models", so unauthenticated users can perform administrative operations. Two conditions apply: the attacker has to be in the same adjacent network, and the RCDP daemon has to be enabled. Because RCDP works at layer 2, a router or firewall in front of the switch does not filter it; any host on the same broadcast domain counts as adjacent.
How severe is it?
Siemens and NVD's v3.0 analysis agree on 8.8: adjacent network, low complexity, no privileges, no user interaction, and high impact on confidentiality, integrity and availability, because administrative actions let an attacker change the switch configuration. NVD's older v2 vector gives partial impacts and 5.8, and that v2 score is the one NVD marks Primary. CISA's ICSA-17-271-01B CSAF (version 4, 2025-08-12) carries the 8.8 v3.1 vector and CWE-1188.
CVE-2017-12736 is not in the CISA KEV catalog as of 2026-11-22 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.01066, the 65.6th percentile, in the 2026-11-21 dataset (CISA KEV, FIRST EPSS).
Which products and versions are affected?
| Product (Siemens wording) | Affected | Fixed |
|---|---|---|
| RUGGEDCOM ROS V4.x devices (i800, i801, i802, i803, M969, M2100, M2200, RMC30, RP110, RS400, RS401, RS416, RS900, RS910, RS920, RS930, RS940G, RS969, RS1600, RS8000, RSG2100, RSG2200, RSG2288, RSG2300, RSG2488, RSG920P families and NC variants) | before V4.3.4 | V4.3.4 |
| RUGGEDCOM ROS V5.x devices (RSG907R, RSG908C, RSG909R, RSG910C, RSL910, RST916C, RST916P, RST2228, RST2228P and the V5.X lines of RMC8388, RS416v2, RS416Pv2, RS900 (32M), RS900G (32M), RSG2100 (32M), RSG2100P (32M), RSG2288, RSG2300, RSG2300P, RSG2488, RSG920P) | before V5.0.1 | V5.0.1 |
| SCALANCE XB-200, XC-200, XP-200, XF-200 and XR-300WG switches (91 entries) | V3.0 up to V3.0.2 | V3.0.2 |
| SCALANCE XM-400 and XR-500 switches (26 entries) | V6.1.0 up to V6.1.1 | V6.1.1 |
The table follows the Siemens CSAF for SSA-856721, version 4 of 2025-08-12, which lists 253 product entries (Siemens SSA-856721 CSAF). The older text edition of the advisory (V1.2, 2018-02-22) told XM-400/XR-500 users to "Install V6.1" although it described the affected range as V6.1 up to V6.1.1; the CSAF corrects this to V6.1.1 or later. NVD's CPE entries for the SCALANCE switches start at 3.0 and 6.1 with no upper bound, so a CPE-only match will keep flagging fixed firmware.
How do you fix or mitigate it?
Update ROS to V4.3.4 or V5.0.1 (or a later release on the same line), SCALANCE XB-200/XC-200/XP-200/XR-300WG to V3.0.2 and XM-400/XR-500 to V6.1.1. Siemens gives one mitigation for all 253 entries: manually deactivate RCDP as the user guide describes, which "completely mitigates the vulnerability". On a commissioned network there is rarely a reason to keep it on. Our SCALANCE and RUGGEDCOM guide covers RCDP alongside the other management services, and the authentication bypass fix guide explains the class. Other layer 2 and management flaws in the same devices include CVE-2021-25667 (STP BPDU stack overflow), CVE-2023-24845 (ROS mirror port injection) and CVE-2012-1803 (the ROS factory account).
Evidence
- NVD (read 2026-11-22): status Modified; published 2017-12-26; NVD Primary CVSS v2 5.8 AV:A/AC:L/Au:N/C:P/I:P/A:P; NVD CVSS v3.0 8.8 and Siemens CVSS v3.1 8.8 both Secondary; CWE-665 (NVD), CWE-1188 (Siemens); CPE: RUGGEDCOM ROS before 4.3.4 and before 5.0.1, SCALANCE XB-200/XC-200/XP-200/XR300-WG from 3.0 and XM-400/XR-500 from 6.1 with no upper bound; reference SSA-856721. — NVD
- Siemens SSA-856721 CSAF version 4 (initial 2017-09-28, current 2025-08-12), read 2026-11-22: 253 known-affected entries; CVSS v3.1 8.8; CWE-1188; fixes ROS V4.3.4 (102 entries) and V5.0.1 (34), SCALANCE XB/XC/XP/XF-200 and XR-300WG V3.0.2 for >=3.0|<3.0.2 (91), XM-400/XR-500 V6.1.1 for >=6.1.0|<6.1.1 (26); mitigation: manually deactivate RCDP, which completely mitigates the vulnerability. — Siemens ProductCERT SSA-856721 (CSAF)
- Siemens SSA-856721 text edition V1.2 (2018-02-22), read 2026-11-22: attacker must be in the same adjacent network and the RCDP daemon must be enabled; XR-500/XM-400 remediation line reads 'Install V6.1' for the range V6.1 to V6.1.1 (excluding). — Siemens ProductCERT SSA-856721
- CISA ICSA-17-271-01B CSAF version 4 (initial 2017-09-28, current 2025-08-12), read 2026-11-22: Siemens Ruggedcom ROS, SCALANCE; CVE-2017-12736 CWE-1188, CVSS v3.1 8.8. — CISA CSAF ICSA-17-271-01B
- CVE record (checked 2026-11-22): state PUBLISHED, CNA Siemens, published 2017-12-26, updated 2025-08-12; CWE-1188; CVSS v3.1 8.8; 253 affected entries. — CVE.org
- Not in the CISA KEV catalog, version 2026.11.20 (1,790 entries), checked 2026-11-22. — CISA KEV
- EPSS 0.01066, percentile 0.65576, dataset 2026-11-21, read 2026-11-22. — FIRST EPSS

Related advisories
Sources
- NVD
- Siemens ProductCERT SSA-856721: Vulnerability in RUGGEDCOM Discovery Protocol (RCDP) of Industrial Communication Devices
- Siemens ProductCERT SSA-856721 (CSAF, version 4)
- CISA CSAF: ICSA-17-271-01B Siemens Ruggedcom ROS, SCALANCE (machine-readable advisory)
- CVE.org record CVE-2017-12736 (CNA: Siemens)
- CISA KEV
- FIRST EPSS
Frequently asked questions
Which firmware fixes CVE-2017-12736?
RUGGEDCOM ROS V4.3.4 for V4.x devices and V5.0.1 for V5.x devices, SCALANCE XB-200, XC-200, XP-200, XF-200 and XR-300WG V3.0.2, and SCALANCE XM-400 and XR-500 V6.1.1, per the Siemens SSA-856721 CSAF (version 4, 2025-08-12).
Can I mitigate CVE-2017-12736 without updating?
Yes. Siemens says that manually deactivating RCDP as the user guide describes completely mitigates the vulnerability. RCDP is only needed to discover and set up devices, so it can be switched off once a switch is commissioned.
Why does NVD show 5.8 when Siemens shows 8.8?
The only score NVD labels Primary for this 2017 record is CVSS v2 5.8, which rates the impacts as partial. NVD's own CVSS v3.0 score and the Siemens CVSS v3.1 score are both 8.8 but are labelled Secondary. All three agree the attacker must be on the adjacent network.
Does a firewall in front of the switch stop RCDP attacks?
No. RCDP is a layer 2 protocol, so it reaches any device on the same broadcast domain without passing a router or firewall. Per Siemens SSA-856721, the attacker has to be in the same adjacent network and the RCDP daemon has to be enabled; segmenting the network and disabling RCDP both reduce exposure.