CVE-2023-24845 is a port-mirroring flaw in Siemens RUGGEDCOM ROS switches: with a mirror port enabled, packets sent into that port are not fully blocked and can reach the mirrored network. NVD scores it 9.8 and Siemens 9.1. Siemens fixes it in ROS V4.3.8 and V5.8.0, but lists no fix for 38 product entries.
Vulnerability summary
CVSS base score
9.8
Critical severity
EPSS score (FIRST)
0.7%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2023-24845 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| RUGGEDCOM ROS V4.x devices: i800, i801, i802, i803, M969, M2100, M2200, RMC30, RMC8388 V4.X, RP110, RS416, RS416P, RS416v2 V4.X, RS416Pv2 V4.X, RS900G, RS900GP, RS900M, RS900W, RS910, RS920, RS930, RS940G, RS969, RSG2100, RSG2100P, RSG2200, RSG2288 V4.X, RSG2300 V4.X, RSG2488 V4.X, RSG920P V4.X and their NC variants | cpe:2.3:o:siemens:ruggedcom_ros:*:*:*:*:*:*:*:* | All versions before V4.3.8; fixed in V4.3.8 (Siemens SSA-908185) |
| RUGGEDCOM ROS V5.x devices: RMC8388 V5.X, RS416v2 V5.X, RS416Pv2 V5.X, RS900 (32M) V5.X, RS900G (32M) V5.X, RSG2100 (32M) V5.X, RSG2288 V5.X, RSG2300 V5.X, RSG2488 V5.X, RSG907R, RSG908C, RSG909R, RSG910C, RSG920P V5.X, RSL910, RST2228, RST916C, RST916P and their NC/P variants | cpe:2.3:o:siemens:ruggedcom_ros:*:*:*:*:*:*:*:* | All versions before V5.8.0; fixed in V5.8.0 (Siemens SSA-908185) |
| RUGGEDCOM RS400, RS401, RS1600 and RS8000 families, fiber-optic F variants (M969F, M2100F, M2200F, RS416F, RS416PF, RS900F, RS900GF, RS900GPF, RS940GF, RSG2100F, RSG2100PF, RSG2200F, RSG2300F, RSG2300PF, RSG2488F) and one of the two listed entries each for RS900, RS900L, RS900NC and RS900LNC | cpe:2.3:o:siemens:ruggedcom_ros:*:*:*:*:*:*:*:* | All versions; no fix intended as of 2026-11-21, ingress-filtering workaround (Siemens SSA-908185) |
What does this mean for affected devices?
NVD carries the Siemens description: "The affected products insufficiently block data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior." NVD's Primary score is CVSS v3.1 9.8 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H) with the placeholder NVD-CWE-Other. The Siemens CNA classes it CWE-684 (incorrect provision of specified functionality). The record was published on 2023-08-08 (NVD, CVE record).
How severe is CVE-2023-24845?
Siemens scores it CVSS v3.1 9.1 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C) in SSA-908185. NVD adds a high integrity impact, which raises its score to 9.8. Both rate the attack as needing no privileges. In a real network, though, the attacker needs a device on the port that receives the mirrored traffic, usually an IDS sensor, a network recorder or an engineering laptop. A mirror port is supposed to be one-way. This flaw makes it a path back into the switched network, for example in a substation or traffic-control cabinet, which is where Siemens says ROS devices are used.
CVE-2023-24845 is not in the CISA KEV catalog as of 2026-11-21 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.00692, the 53.8th percentile, in the 2026-11-20 dataset (CISA KEV, FIRST EPSS).
Which RUGGEDCOM devices are affected?
SSA-908185 (version 3, updated 2025-08-12) lists 156 product entries:
| Group (Siemens wording) | Fixed |
|---|---|
| ROS V4.x devices such as the i800 series, M969, M2100, M2200, RMC30, RP110, RS416, RS900G, RS900M, RS910, RS940G, RSG2100, RSG2200, RSG2288 V4.X, RSG2300 V4.X and RSG2488 V4.X | V4.3.8 |
| ROS V5.x devices such as the RMC8388 V5.X, RS416v2 V5.X, RS900 (32M) V5.X, RSG2288 V5.X, RSG2300 V5.X, RSG2488 V5.X, RSG907R, RSG908C, RSG909R, RSG910C, RSL910, RST2228 and RST916C/P | V5.8.0 |
| RS400, RS401, RS1600 and RS8000 families and fiber-optic F variants such as the RSG2100F, RSG2300F and RSG2488F | no fix intended |
The RS900, RS900L, RS900NC and RS900LNC each appear twice in the advisory: one entry is fixed in V4.3.8 and the other has no fix intended. The advisory does not say what separates the two entries, so apply the workaround on these models even after an update to V4.3.8. NVD's CPE list uses one product, ruggedcom_ros, with V4.x before 4.3.8 and all V5.x versions, so it does not show the V5.8.0 fix. Use the Siemens list to match exact models (Siemens SSA-908185 CSAF).
How do you fix or mitigate it?
Update ROS V4.x devices to V4.3.8 or later and ROS V5.x devices to V5.8.0 or later. For every affected device, including the 38 with no fix, Siemens gives a workaround for ports used as mirror targets: enable ingress filtering, and disable RSTP, the neighbor discovery protocol and LLDP on the target port. Also check what is plugged into each mirror port, and treat that device as part of the protected network.
Other RUGGEDCOM ROS flaws include the DHCP client overflow CVE-2021-31895 and the 2012 factory account CVE-2012-1803. Our SCALANCE and RUGGEDCOM vulnerability guide covers the whole product range, and the input-handling fix guide explains this class of weakness.
Evidence
- NVD (read 2026-11-21): status Modified; published 2023-08-08; NVD Primary CVSS v3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H; Siemens Secondary 9.1; CWE NVD-CWE-Other (NVD), CWE-684 (Siemens); CPE cpe:2.3:o:siemens:ruggedcom_ros 4.0.0 to before 4.3.8 and from 5.0.0 without upper bound. — NVD
- Siemens SSA-908185 version 3 (published 2023-08-08, updated 2025-08-12), read 2026-11-21: 156 affected product entries; CVSS v3.1 9.1 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C, CWE-684; fixes V4.3.8 and V5.8.0; no fix intended for 38 entries (RS400, RS401, RS1600, RS8000 families, F variants and one entry each of RS900, RS900L, RS900NC, RS900LNC, which also appear with the V4.3.8 fix); workaround: enable ingress filtering, disable RSTP, neighbor discovery and LLDP on target ports; ROS devices are used in electric utility substations and traffic control cabinets. — Siemens ProductCERT SSA-908185
- CVE record (checked 2026-11-21): state PUBLISHED, CNA Siemens, published 2023-08-08; CWE-684; CNA CVSS v3.1 9.1. — CVE.org
- Not in the CISA KEV catalog, version 2026.11.20 (1,790 entries), checked 2026-11-21. — CISA KEV
- EPSS 0.00692, percentile 0.53786, dataset 2026-11-20, read 2026-11-21. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which ROS versions fix CVE-2023-24845?
ROS V4.3.8 for devices on the V4.x line and ROS V5.8.0 for devices on the V5.x line, per Siemens SSA-908185. NVD's CPE data does not show the V5.8.0 fix, so check the Siemens product list for your exact model.
Which RUGGEDCOM devices will not get a fix?
Siemens lists no fix for 38 product entries: the RS400, RS401, RS1600 and RS8000 families, fiber-optic F variants such as the M969F, RSG2100F, RSG2300F and RSG2488F, and one of the two entries each for the RS900, RS900L, RS900NC and RS900LNC. For these, the ingress-filtering workaround is the only measure.
What is the workaround?
On every port used as a mirror target, enable ingress filtering, and disable RSTP, the neighbor discovery protocol and LLDP. Siemens gives this for all 156 affected product entries in SSA-908185, so it also applies while a fixed firmware is being rolled out.
Who can exploit it in practice?
The scores assume network access with no privileges. In practice, the attacker needs a device on the mirror target port, such as a compromised IDS sensor, network recorder or laptop. That device can then send packets into the mirrored network, which should only ever be observed through that port.
Questions about this page?