CVE-2021-22797 is a path traversal flaw (CWE-22) in Schneider Electric's EcoStruxure Control Expert, Process Expert and SCADAPack RemoteConnect engineering software. A malicious project file could place a script in an unauthorized location and run code on the engineering workstation. NVD scores it 7.8. Control Expert V15.1, Process Expert 2021 and RemoteConnect R2.7.3 fix it.
Vulnerability summary
CVSS base score
7.8
High severity
EPSS score (FIRST)
26.1%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2021-22797 · Source: NVD

Affected components
| Component | CPE | Version range |
|---|---|---|
| Schneider Electric EcoStruxure Control Expert (including former Unity Pro) | cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:* | V15.0 SP1 and prior; fixed in V15.1 |
| Schneider Electric EcoStruxure Process Expert (including former HDCS) | cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:* | 2020 and prior; fixed in 2021 |
| Schneider Electric SCADAPack RemoteConnect for x70 (SCADAPack 470, 474, 570, 574, 575) | cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:* | All versions prior to R2.7.3; fixed in R2.7.3 |
What does this mean for affected devices?
Schneider's notice SEVD-2021-257-01, released on 14 September 2021 and revised to V3.0 on 12 July 2022, describes a path traversal "that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software." Control Expert, formerly Unity Pro, programs Modicon M340, M580, Momentum, Premium and Quantum PLCs; Process Expert is Schneider's DCS engineering suite; RemoteConnect configures the SCADAPack 470, 474, 570, 574 and 575 RTUs. Schneider credits Kimiya, working with Trend Micro's Zero Day Initiative.
How severe is CVE-2021-22797?
NVD's Primary score is CVSS v3.1 7.8, AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H, the same vector Schneider and CISA use, and NVD also keeps a Primary CVSS v2 score of 9.3 (NVD). The CWE, CWE-22, comes from Schneider. CISA's ICSA-21-259-02 of 16 September 2021 lists all versions of the three products as affected, because no fix existed at the time.
Which versions are affected and what is the fix?
Schneider's current notice lists Control Expert V15.0 SP1 and prior, Process Expert 2020 and prior and SCADAPack RemoteConnect for x70 before R2.7.3. Version 2.0 of the notice (8 March 2022) added the fixes in Control Expert V15.1 and Process Expert 2021; version 3.0 added RemoteConnect R2.7.3, and Schneider notes that RemoteConnect no longer needs updating for each Control Expert update. Unity Pro users should migrate to Control Expert.
Owners who cannot update should store project files in secure storage open only to trusted users, exchange them over secure protocols, compute and check a checksum on each project file before use, harden the workstation, and start the software without administrator rights so extracted files cannot land in critical system folders.
The Schneider EcoStruxure HMI and SCADA software guide covers the Control Expert project-file flaws together; the write-what-where flaw CVE-2020-7560 and the Xmill overflow CVE-2022-26507 are its neighbours. With an EPSS score far above the rest of the Schneider software set, it is a case for the KEV and EPSS prioritization guide; the path traversal fix guide covers the weakness class.
Is CVE-2021-22797 exploited?
It is not in the CISA KEV catalog as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS gives it 0.261, the 98th percentile, in the 2026-11-27 dataset (CISA KEV, FIRST EPSS).


Evidence
- NVD (read 2026-11-28): published 2022-04-13, status Modified; NVD Primary CVSS v3.1 7.8 AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H; NVD Primary CVSS v2 9.3 AV:N/AC:M/Au:N/C:C/I:C/A:C; Schneider Secondary CVSS v3.1 7.8 same vector; CWE-22 (Schneider; no NVD Primary CWE); CPE ecostruxure_control_expert before 15.1, ecostruxure_process_expert before 2021, remoteconnect (running on SCADAPack 470/474/570/574/575). — NVD
- Schneider SEVD-2021-257-01 V3.0 (14 September 2021, revised 12 July 2022, PDF and Schneider CSAF read 2026-11-28): affected Control Expert V15.0 SP1 and prior (incl. Unity Pro), Process Expert 2020 and prior (incl. HDCS), SCADAPack RemoteConnect for x70 prior to R2.7.3; fixes Control Expert V15.1, Process Expert 2021 (V2.0, 8 March 2022), RemoteConnect R2.7.3 (V3.0); mitigations (secure storage, secure protocols, hardening, checksum, no administrator rights); credit Kimiya with ZDI. — Schneider Electric
- CISA ICSA-21-259-02 CSAF (2021-09-16): CWE-22, CVSS v3 7.8 AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H; affected all versions of Control Expert (incl. Unity Pro), Process Expert (incl. HDCS) and SCADAPack RemoteConnect for x70; mitigations only; migrate from Unity Pro to Control Expert. — CISA
- CVE.org record (read 2026-11-28): assigner Schneider Electric, CWE-22, CVSS v3.1 7.8; affected Control Expert before V15.0 SP1 (as recorded), Process Expert before 2020, SCADAPack RemoteConnect for x70 all versions. — CVE.org
- Not in the CISA KEV catalog, catalog version 2026.11.27, 1,808 entries, checked 2026-11-28. — CISA KEV
- EPSS 0.261, percentile 0.98446, dataset 2026-11-27, read 2026-11-28. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Is there a fixed version of Control Expert for CVE-2021-22797?
Yes. Schneider's SEVD-2021-257-01 V2.0 of March 2022 names Control Expert V15.1 and Process Expert 2021 as fixed, and V3.0 of July 2022 adds SCADAPack RemoteConnect R2.7.3. CISA's September 2021 advisory predates those fixes and lists mitigations only.
Does this affect the PLC or RTU itself?
No. The flaw is in the Windows engineering software that opens project files. Schneider names code execution on the engineering workstation as the impact; the Modicon PLCs and SCADAPack RTUs are the devices that software configures.
What should I do if I cannot update?
Schneider asks owners to keep project files in secure storage open only to trusted users, exchange them over secure protocols, verify a checksum before opening, harden the workstation and run the software without administrator rights.
Is CVE-2021-22797 in the CISA KEV catalog?
No, not as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS rates it 0.261, the 98th percentile, in the 2026-11-27 dataset.
Questions about this page?