Security Advisory

CVE-2020-8597: pppd EAP Buffer Overflow

Last updated:
  • CVE-2020-8597

CVE-2020-8597 is a stack buffer overflow in the EAP code of pppd, the PPP daemon in ppp 2.4.2 through 2.4.8, that the peer on a PPP link can trigger before authentication and even when EAP was never negotiated. NVD scores it 9.8, and Siemens fixed it in SCALANCE M-800, S615 and RUGGEDCOM RM1224 LTE routers in V6.3.

Vulnerability summary

CVSS base score

9.8

Critical severity

EPSS score (FIRST)

19.9%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2020-8597 · Source: NVD

Affected components

ComponentCPEVersion range
ppp (pppd)cpe:2.3:a:point-to-point_protocol_project:point-to-point_protocol:*:*:*:*:*:*:*:*2.4.2 through 2.4.8 (fixed by upstream commit 8d7970b8, first released in 2.4.9)
Siemens SCALANCE M-800 / S615—all versions before V6.3 (fixed in V6.3, per Siemens SSA-809841 / CISA ICSA-20-224-04)
Siemens RUGGEDCOM RM1224—all versions before V6.3 (fixed in V6.3, per Siemens SSA-809841 / CISA ICSA-20-224-04)
NETGEAR WAC510—firmware before 8.2.6.7 (per NETGEAR PSV-2020-0136)

What does this mean for affected devices?

CVE-2020-8597 is a classic buffer copy without a size check (CWE-120) in eap.c of pppd. NVD describes an "rhostname buffer overflow in the eap_request and eap_response functions" affecting ppp 2.4.2 through 2.4.8 and scores it 9.8 (critical) with vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (NVD). The upstream fix changes one bounds comparison in each of eap_request() and eap_response(), and the first release that contains it is ppp 2.4.9.

CERT/CC's VU#782301, published on 2020-03-04, says that "by sending an unsolicited EAP packet to a vulnerable ppp client or server, an unauthenticated remote attacker could cause memory corruption in the pppd process, which may allow for arbitrary code execution", and that there is no viable workaround except patching. Its vendor list marks embedded vendors such as OpenWRT, Sierra Wireless, TP-LINK, Ubiquiti Networks, PePLink, Synology and Wind River as affected.

Industrial cellular routers are the clearest device case. Siemens' SSA-809841, republished by CISA as ICSA-20-224-04 on 2020-08-11, fixes the flaw in SCALANCE M-800 and S615 industrial routers and the RUGGEDCOM RM1224 LTE router: all versions before V6.3 are affected and V6.3 fixes them. Siemens notes the PPP function is off by default but used for internet dial-in and point-to-point connections, "at this point the vulnerability could be exploited by a malicious peer". NETGEAR's PSV-2020-0136 fixes the same pppd flaw in the WAC510 access point in firmware 8.2.6.7.

On a device, the attacker is whoever answers on the other end of the link: a rogue PPPoE access concentrator on the WAN segment, a carrier-side or fake base station path on a cellular modem, a dial-in caller on a serial port, or any client of a PPTP or L2TP server. Our pppd vulnerabilities in embedded firmware guide shows how to find the pppd version in an image from the plugin directory, binary strings and package records, and why refusing EAP in the options file does not stop this bug on unpatched 2.4.x builds.

This CVE is not in the CISA KEV catalog as of 2026-11-16 (catalog version 2026.11.13), but FIRST EPSS gives it 0.199, the 97th percentile, in its 2026-11-15 dataset (CISA KEV, FIRST EPSS). Our KEV and EPSS prioritisation guide explains how to weigh that gap. Old distribution builds were fixed by backport: the Debian tracker lists 2.4.6-3.1+deb8u1 (DLA-2097-1) and 2.4.7 builds for stretch and buster (DSA-4632-1), so a version string below 2.4.9 does not by itself prove a device is vulnerable.

For device makers the fix is ppp 2.4.9 or later, or a backport of commit 8d7970b8 on 2.4.x trees; our memory corruption fix guide covers verifying that kind of bounds-check patch in the shipped binary. Operators of the Siemens routers should update to V6.3 and, per Siemens, use the PPP function only in trusted environments until then.

How to fix this class of issueThis advisory's weakness class is Memory corruption. Our practical guide covers how to detect, fix, verify and disclose it: How to fix memory corruption in embedded firmware.

Evidence

  • Stack overflow in eap_request and eap_response in ppp 2.4.2 through 2.4.8; NVD CVSS v3.1 9.8, CWE-120. — NVD
  • An unauthenticated remote attacker can send an unsolicited EAP packet to corrupt pppd memory; no viable workaround except patching. — CERT/CC VU#782301
  • SCALANCE M-800 / S615 and RUGGEDCOM RM1224 before V6.3 affected, fixed in V6.3; PPP off by default. — Siemens SSA-809841
  • CISA republished the Siemens advisory as ICSA-20-224-04 on 2020-08-11. — CISA ICS Advisory ICSA-20-224-04
  • NETGEAR WAC510 firmware before 8.2.6.7 affected, fixed in 8.2.6.7. — NETGEAR PSV-2020-0136
  • Not in the CISA KEV catalog as of 2026-11-16 (catalog version 2026.11.13). — CISA KEV
  • EPSS 0.19925 (97.5th percentile), dataset 2026-11-15, read 2026-11-16. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CERT/CC VU#782301
  3. Siemens SSA-809841
  4. CISA ICS Advisory ICSA-20-224-04
  5. NETGEAR PSV-2020-0136
  6. ppp-project/ppp commit 8d7970b8
  7. Debian Security Tracker
  8. CISA KEV
  9. FIRST EPSS

Frequently asked questions

Does refusing EAP protect pppd against CVE-2020-8597?

No. CERT/CC VU#782301 explains that an unsolicited EAP packet reaches the vulnerable code, and it lists no viable workaround except patching. The fix is ppp 2.4.9 or a backport of upstream commit 8d7970b8 (per CERT/CC VU#782301 and the ppp project).

Which industrial devices are affected by CVE-2020-8597?

Siemens SSA-809841, republished by CISA as ICSA-20-224-04, lists SCALANCE M-800 / S615 industrial routers and the RUGGEDCOM RM1224 LTE router, all versions before V6.3, fixed in V6.3. NETGEAR also fixed the WAC510 access point in firmware 8.2.6.7 (per Siemens, CISA and NETGEAR).

Who can exploit CVE-2020-8597 on a router?

The peer on the PPP link: a rogue PPPoE server on the WAN segment, a dial-in caller, or a client of a PPTP or L2TP server running pppd. Siemens notes its routers are exposed when the PPP function, off by default, is used for dial-in or point-to-point connections (per Siemens SSA-809841).

Is CVE-2020-8597 actively exploited?

It is not in the CISA KEV catalog as of 2026-11-16 (catalog version 2026.11.13), but FIRST EPSS gives it 0.199, the 97th percentile, in the 2026-11-15 dataset, so it ranks high for patching (per CISA KEV and FIRST EPSS).