CVE-2020-28391 means Siemens SCALANCE X-200, X-200IRT and X-200RNA switches used with a C-PLUG module keep the RSA private key shipped inside the firmware image instead of creating their own, so an attacker could decrypt captured traffic or sit in the middle. NVD scores it 5.9; Siemens scores it 9.1. Fixed in X-200 V5.2.5, X-200IRT V5.5.0 and X-200RNA V3.2.7.
Vulnerability summary
CVSS base score
5.9
Medium severity
EPSS score (FIRST)
1.1%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2020-28391 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| SCALANCE X-200 switch family (incl. SIPLUS NET variants) | cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:* | All versions before V5.2.5; fixed in V5.2.5 (Siemens SSA-274900) |
| SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) | cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:* | All versions before V5.5.0; fixed in V5.5.0 (Siemens SSA-274900) |
| SCALANCE X-200RNA switch family | — | All versions before V3.2.7; fixed in V3.2.7 (Siemens SSA-274900, added 2022-12-13). No NVD CPE entry |
What does this mean for affected devices?
NVD carries the Siemens description: SCALANCE X-200, X-200IRT and X-200RNA switches "create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic." NVD's Primary score is CVSS v3.1 5.9 (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N) with CWE-798 (hard-coded credentials); the Siemens CNA classes it CWE-321 (use of a hard-coded cryptographic key). The record was published on 2021-01-12 (NVD, CVE record).
How severe is it, and why do the scores differ?
Siemens ProductCERT scores CVE-2020-28391 at CVSS v3.1 9.1 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:U/RC:C) in SSA-274900, and CISA's ICSA-21-012-02 CSAF (Update B, 2022-12-13) repeats that vector. NVD rates attack complexity high and integrity impact none, which gives 5.9; Siemens rates complexity low and integrity impact high, which gives 9.1. Read the vector rather than one number.
CVE-2020-28391 is not in the CISA KEV catalog as of 2026-11-22 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.01132, the 67.2nd percentile, in the 2026-11-21 dataset (CISA KEV, FIRST EPSS).
Why does C-PLUG matter?
C-PLUG is the removable configuration module of SCALANCE X switches. Without it, a factory reset makes the switch generate a fresh key. With it, the switch falls back to the RSA private key that ships inside every copy of the firmware image. Because the key is part of the firmware image, it is not unique to one device, and Siemens says an attacker could use it to get into a man-in-the-middle position and decrypt previously captured traffic. Siemens publishes the fingerprints of the built-in certificates so operators can check: SHA-1 F2:C8:3B:8F:86:27:74:AA:60:EC:D4:A0:CF:0D:BE:A6:D1:FE:22:12 for X-200 and X-200IRT, and SHA-1 04:64:EF:98:A4:42:D2:BB:57:4A:47:12:20:EC:E6:85:15:4F:03:61 for X-200RNA (SHA-256 values are in the advisory).
Which products and versions are affected?
| Product (Siemens wording) | Affected | Fixed |
|---|---|---|
| SCALANCE X-200 switch family (incl. SIPLUS NET variants) | before V5.2.5 | V5.2.5 |
| SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) | before V5.5.0 | V5.5.0 |
| SCALANCE X-200RNA switch family | before V3.2.7 | V3.2.7 |
The table follows the Siemens CSAF for SSA-274900, version 4 of 2022-12-13 (Siemens SSA-274900 CSAF). Siemens added the X-200IRT fix in February 2021, the X-200 fix in September 2021 and the X-200RNA family in December 2022. NVD's 66 CPE entries do not line up with this table: they list six X-200IRT models before 5.5.0, 48 XB-, XC-, XF- and XP-prefixed models before 5.2.5, and 12 X-300 models (X307 to X320) with no upper version, although Siemens names the X-300 family only under CVE-2020-28395. There is no X-200RNA entry, so a CPE-only scan misses the RNA switches.
How do you fix or mitigate it?
Update X-200 to V5.2.5, X-200IRT to V5.5.0 and X-200RNA to V3.2.7 or later. Siemens gives two mitigations: replace the default self-signed device X.509 certificates with your own trusted certificates, and replace the default hard-coded certificates from the firmware image (identified by the fingerprints above). Updating alone does not help a switch that kept the shipped key; check the certificate fingerprint after the update. Treat captured traffic from before the change as readable. Our SCALANCE and RUGGEDCOM guide covers C-PLUG and backup handling, and the weak cryptography fix guide explains the class. The same advisory lists CVE-2020-28395, where X-200RNA and X-300 switches keep the shipped key after any factory reset. CVE-2019-6567 (recoverable passwords) and CVE-2021-25668 (X-200 web server heap overflow) affect the same family.
Evidence
- NVD (read 2026-11-22): status Modified; published 2021-01-12; NVD Primary CVSS v3.1 5.9 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N, v2 4.3; CWE-798 (NVD), CWE-321 (Siemens); 66 vulnerable CPE entries: 6 X-200IRT models before 5.5.0, 48 XB/XC/XF/XP-prefixed models before 5.2.5, 12 X-300 models (X307 to X320) without version limit, none for X-200RNA; references SSA-274900, ICSA-21-012-02. — NVD
- Siemens SSA-274900 CSAF version 4 (initial 2021-01-12, current 2022-12-13), read 2026-11-22: CVE-2020-28391 CWE-321, CVSS v3.1 9.1 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N/E:P/RL:U/RC:C; X-200 fixed V5.2.5, X-200IRT V5.5.0, X-200RNA V3.2.7; mitigations: replace default self-signed X.509 certificates with own trusted certificates and replace the default hard-coded certificates (SHA-1 F2:C8:3B:8F:86:27:74:AA:60:EC:D4:A0:CF:0D:BE:A6:D1:FE:22:12; X-200RNA SHA-1 04:64:EF:98:A4:42:D2:BB:57:4A:47:12:20:EC:E6:85:15:4F:03:61); revisions 2021-02-09 (X-200IRT fix), 2021-09-14 (X-200 fix), 2022-12-13 (added X-200RNA). — Siemens ProductCERT SSA-274900 (CSAF)
- CISA ICSA-21-012-02 CSAF (Update B, version 4, current 2022-12-13), read 2026-11-22: Siemens SCALANCE X Switches; CVE-2020-28391 CWE-321, CVSS v3.1 9.1. — CISA CSAF ICSA-21-012-02
- CVE record (checked 2026-11-22): state PUBLISHED, CNA Siemens, published 2021-01-12; CWE-321. — CVE.org
- Not in the CISA KEV catalog, version 2026.11.20 (1,790 entries), checked 2026-11-22. — CISA KEV
- EPSS 0.01132, percentile 0.67249, dataset 2026-11-21, read 2026-11-22. — FIRST EPSS

Related advisories
Sources
- NVD
- Siemens ProductCERT SSA-274900: Use of Hardcoded Key in SCALANCE X Devices Under Certain Conditions
- Siemens ProductCERT SSA-274900 (CSAF, version 4)
- CISA CSAF: ICSA-21-012-02 Siemens SCALANCE X Switches (Update B, machine-readable advisory)
- CVE.org record CVE-2020-28391 (CNA: Siemens)
- CISA KEV
- FIRST EPSS
Frequently asked questions
Which firmware fixes CVE-2020-28391?
SCALANCE X-200 V5.2.5, X-200IRT V5.5.0 and X-200RNA V3.2.7, per the Siemens SSA-274900 CSAF (version 4, 2022-12-13). The X-200RNA family was added to the advisory in December 2022.
Am I affected if I do not use C-PLUG?
According to Siemens, X-200 and X-200IRT switches create a new unique key on factory reset unless they are used with C-PLUG; with C-PLUG they use the hard-coded RSA key from the firmware image. Check the device certificate fingerprint against the values in SSA-274900 to see whether a switch is running with the shipped key.
Why does NVD score 5.9 and Siemens 9.1?
NVD rates attack complexity high and integrity impact none (5.9). Siemens rates complexity low and integrity impact high (9.1). Both rate confidentiality high and require no privileges or user interaction (per NVD and Siemens SSA-274900).
What should I do besides updating?
Siemens recommends replacing the default self-signed device certificates with your own trusted certificates and replacing the hard-coded certificates from the firmware image. Treat traffic captured before the change as readable, and restrict access to C-PLUG modules and the management network.