CVE-2021-25668 is a heap-based buffer overflow in the web server of Siemens SCALANCE X-200 and X-200IRT industrial Ethernet switches: an unauthenticated attacker who can reach the web interface sends a crafted POST request and can crash the switch or potentially run code on it. NVD and Siemens both score it 9.8 (CWE-122). Siemens fixes it in V5.2.5 and V5.5.1.

Vulnerability summary

CVSS base score

9.8

Critical severity

EPSS score (FIRST)

1.7%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2021-25668 · Source: NVD

Affected components

ComponentCPEVersion range
SCALANCE X-200 switches: X204-2, X204-2FM, X204-2LD, X204-2LD TS, X204-2TS, X206-1, X206-1LD, X208, X208PRO, X212-2, X212-2LD, X216, X224, XF204, XF204-2, XF206-1, XF208 (incl. SIPLUS NET variants)cpe:2.3:o:siemens:scalance_x204-2_firmware:*:*:*:*:*:*:*:*All versions before V5.2.5; fixed in V5.2.5 (Siemens SSA-187092)
SCALANCE X-200IRT switches: X200-4P IRT, X201-3P IRT, X201-3P IRT PRO, X202-2 IRT, X202-2P IRT, X202-2P IRT PRO, X204 IRT, X204 IRT PRO, XF201-3P IRT, XF202-2P IRT, XF204 IRT, XF204-2BA IRT (incl. SIPLUS NET variant)cpe:2.3:o:siemens:scalance_x204_irt_firmware:*:*:*:*:*:*:*:*All versions before V5.5.1; fixed in V5.5.1 (Siemens SSA-187092)

What does this mean for affected devices?

NVD carries the Siemens description: "Incorrect processing of POST requests in the webserver may result in write out of bounds in heap. An attacker might leverage this to cause denial-of-service on the device and potentially remotely execute code." NVD's Primary score is CVSS v3.1 9.8 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H) with CWE-787; the Siemens CNA classes it CWE-122 (heap-based buffer overflow). The record was published on 2021-04-22 (NVD, CVE record).

How severe is CVE-2021-25668?

Siemens ProductCERT gives the same base score, CVSS v3.1 9.8 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C), in SSA-187092. The vector needs no privileges and no user interaction, so anyone who can open a connection to the switch's web server on 80/tcp or 443/tcp is in a position to try it. The temporal part, exploit code maturity "proof of concept", is Siemens' own assessment. CISA republished the advisory as ICSA-21-103-07 with the same 9.8.

Which switches are affected?

Product line (Siemens wording) Affected Fixed
SCALANCE X-200: X204-2, X204-2FM, X204-2LD, X204-2LD TS, X204-2TS, X206-1, X206-1LD, X208, X208PRO, X212-2, X212-2LD, X216, X224, XF204, XF204-2, XF206-1, XF208 before V5.2.5 V5.2.5
SCALANCE X-200IRT: X200-4P IRT, X201-3P IRT (and PRO), X202-2 IRT, X202-2P IRT (and PRO), X204 IRT (and PRO), XF201-3P IRT, XF202-2P IRT, XF204 IRT, XF204-2BA IRT before V5.5.1 V5.5.1

SIPLUS NET variants of the X202-2P IRT, X204-2, X204-2LD, X208, X212-2 and XF204-2 are included. SSA-187092 was published on 2021-04-13 with a fix for the IRT models only; version 1.1 of 2021-09-14 added V5.2.5 for the X-200 line. NVD's CPE list matches these 29 models and fixed versions. The same advisory carries the stack-based twin CVE-2021-25669, and both are closed by the same update.

How do you fix or mitigate it?

Update X-200 switches to V5.2.5 or later and X-200IRT switches to V5.5.1 or later. Until then, Siemens' mitigation is to limit traffic to the web server to trusted connections with firewall rules on 443/tcp and 80/tcp. On these switches the web server is the web-based management (WBM) interface, so restrict it to the engineering workstation. CVE-2019-10942 hits the Telnet service of the same switch families, and CVE-2019-13933 the WBM of the related X-200RNA and X-300 switches. Our SCALANCE and RUGGEDCOM vulnerability guide covers the whole product range, and the memory corruption fix guide explains this class of bug in firmware.

CVE-2021-25668 is not in the CISA KEV catalog as of 2026-11-21 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.01741, the 78.3rd percentile, in the 2026-11-20 dataset (CISA KEV, FIRST EPSS).

How to fix this class of issueThis advisory's weakness class is Memory corruption. Our practical guide covers how to detect, fix, verify and disclose it: How to fix memory corruption in embedded firmware.

Evidence

  • NVD (read 2026-11-21): status Modified; published 2021-04-22; NVD Primary CVSS v3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, v2 7.5; CWE-787 (NVD), CWE-122 (Siemens); CPE: 17 X-200 models before 5.2.5 and 12 X-200IRT models before 5.5.1; reference SSA-187092. — NVD
  • Siemens SSA-187092 V1.1 (published 2021-04-13, updated 2021-09-14), CSAF read 2026-11-21: CVE-2021-25668 heap-based buffer overflow (CWE-122) from incorrect processing of POST requests in the web server; CVSS v3.1 9.8 with E:P/RL:O/RC:C; fixes V5.2.5 for 17 X-200 models and V5.5.1 for 12 X-200IRT models; mitigation: limit web server traffic to trusted connections by firewall rules on 443/tcp and 80/tcp. — Siemens ProductCERT SSA-187092
  • CISA ICSA-21-103-07 CSAF (Update A, current release 2025-05-06), read 2026-11-21: CVE-2021-25668 CWE-122, CVSS v3.1 9.8; SCALANCE X200 web server. — CISA CSAF ICSA-21-103-07
  • CVE record (checked 2026-11-21): state PUBLISHED, CNA Siemens, published 2021-04-22; CNA CWE-122; no CNA CVSS metric in the record. — CVE.org
  • Not in the CISA KEV catalog, version 2026.11.20 (1,790 entries), checked 2026-11-21. — CISA KEV
  • EPSS 0.01741, percentile 0.78305, dataset 2026-11-20, read 2026-11-21. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. Siemens ProductCERT SSA-187092: Several Buffer-Overflow Vulnerabilities in Web Server of SCALANCE X-200
  3. Siemens ProductCERT SSA-187092 (CSAF)
  4. CISA CSAF: ICSA-21-103-07 Siemens Web Server of SCALANCE X200 (machine-readable advisory)
  5. CVE.org record CVE-2021-25668 (CNA: Siemens)
  6. CISA KEV
  7. FIRST EPSS

Frequently asked questions

Which firmware fixes CVE-2021-25668?

V5.2.5 for the SCALANCE X-200 switches (X204-2 to X224, XF204 to XF208) and V5.5.1 for the X-200IRT switches (X200-4P IRT to XF204-2BA IRT), including the SIPLUS NET variants (per Siemens SSA-187092).

Does an attacker need a password?

No. Both Siemens and NVD score it with no privileges and no user interaction required: a crafted POST request to the web server is enough. Network access to the web interface on 80/tcp or 443/tcp is the only precondition (per NVD and Siemens SSA-187092).

What can I do before I can update?

Siemens recommends limiting traffic to the web servers of SCALANCE X switches to trusted connections with firewall rules on 443/tcp and 80/tcp (per SSA-187092). In practice, allow only the engineering workstation to reach the switch management interface.

How is it related to CVE-2021-25669?