CVE-2020-27254 is an authentication gap in the web interface of Emerson Rosemount X-STREAM enhanced gas analyzers (XEGP, XEGK, XEFD and XEXF). A specially crafted URL lets an attacker download log and backup data without logging in. NVD and CISA both score it 7.5. Emerson released new firmware, obtained through its technical support.
Vulnerability summary
CVSS base score
7.5
High severity
EPSS score (FIRST)
1.3%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2020-27254 · Source: NVD

Affected components
| Component | CPE | Version range |
|---|---|---|
| Emerson Rosemount X-STREAM enhanced gas analyzers XEGP, XEGK, XEFD, XEXF | cpe:2.3:o:emerson:x-stream_enhanced_xegp_firmware:*:*:*:*:*:*:*:* | All revisions before Emerson's firmware update (CISA ICSA-20-352-01, NVD); new firmware from Emerson technical support |
What does this mean for affected devices?
The CVE record from CISA says that the Emerson Rosemount X-STREAM Gas Analyzer, "X-STREAM enhanced XEGP, XEGK, XEFD, XEXF – all revisions", is "vulnerable to improper authentication for accessing log and backup data, which could allow an attacker with a specially crafted URL to obtain access to sensitive information." NVD's Primary score and CISA's score are both 7.5 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N; NVD's CVSS 2.0 score is 5.0), and both map it to CWE-287, improper authentication. NVD's configuration lists the firmware of all four analyzer models with no version bound (NVD, CVE record).
Which Emerson analyzers are affected?
CISA's ICSA-20-352-01, released on 2020-12-17, lists all revisions of the X-STREAM enhanced XEGK, XEXF, XEGP and XEFD gas analyzers, deployed worldwide in the Energy and Chemical sectors. Maxim Rupp reported the flaw to CISA. CISA's summary is that a specially crafted URL could let an attacker download files and obtain sensitive information.
How do you fix CVE-2020-27254?
Emerson recommends updating the firmware of every affected analyzer; CISA records that a new release addressing the issue is available through Emerson's technical support, with no public download or version number given in the advisory. Emerson also asks users to keep the analyzers on a well-protected network, segmented from the internet. In practice:
- request the fixed firmware from Emerson support and record the new revision for each analyzer;
- keep the analyzer's web interface off the internet and off the business network, reachable only from the analyzer house or control system hosts;
- review who can reach the analyzer's HTTP port and remove unneeded firewall rules.
Our Emerson guide collects other Emerson advisories, including the Rosemount gas chromatograph command injection CVE-2023-46687 and the HART DTM crash CVE-2014-9191. The authentication bypass fix guide covers how vendors enforce authentication on every route of an embedded web server.
Is CVE-2020-27254 exploited?
CVE-2020-27254 is not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS gives it 0.01286, the 70.20th percentile, in the 2026-11-26 dataset (CISA KEV, FIRST EPSS). CISA reported no known public exploits specifically targeting this vulnerability.


Evidence
- NVD (read 2026-11-27): status Modified; published 2020-12-21; [email protected] Primary CVSS 3.1 7.5 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N, CVSS 2.0 5.0; CWE-287 (NVD and ICS-CERT); CPE emerson x-stream_enhanced_xegp/xegk/xefd/xexf firmware, no version. — NVD
- CISA ICSA-20-352-01 (2020-12-17): X-STREAM enhanced XEGK, XEXF, XEGP, XEFD all versions; CWE-287 CVSS 3.0 7.5 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N; Emerson recommends updating firmware, new release via Emerson technical support; segment from the internet; Energy, Chemical; reported by Maxim Rupp; no known public exploits. — CISA CSAF
- CVE.org record (CNA icscert): published 2020-12-21; X-STREAM enhanced XEGP, XEGK, XEFD, XEXF all revisions; CWE-287; no CVSS. — CVE.org
- CISA KEV catalog version 2026.11.25, 1,805 entries: CVE-2020-27254 not listed; checked 2026-11-27. — CISA KEV
- EPSS 0.01286, percentile 0.70199, dataset 2026-11-26, read 2026-11-27. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which Emerson analyzers are affected by CVE-2020-27254?
Rosemount X-STREAM enhanced gas analyzers XEGP, XEGK, XEFD and XEXF, all revisions before Emerson's firmware update, per CISA ICSA-20-352-01 and NVD.
How do I fix CVE-2020-27254?
Request the new firmware release from Emerson technical support and update every affected analyzer. Keep the analyzer's web interface segmented from the internet and the business network.
What data does CVE-2020-27254 expose?
Log and backup data on the analyzer, reachable with a specially crafted URL and no login. CISA says an attacker could download files and obtain sensitive information.
Is CVE-2020-27254 in the CISA KEV catalog?
No, not as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS rates it 0.01286, the 70.20th percentile, in the 2026-11-26 dataset.