Security Advisory

CVE-2017-7924: MicroLogix 1100 PCCC Packet DoS

Last updated:
  • CVE-2017-7924

CVE-2017-7924 is an improper input validation flaw (CWE-20) in Rockwell Automation MicroLogix 1100 controllers: a remote, unauthenticated attacker can send one specially crafted PCCC packet that may put the controller into a denial-of-service condition. NVD scores it 7.5 (high). Rockwell's fix, as published by CISA, is MicroLogix 1100 firmware FRN 16.0 or later.

Vulnerability summary

CVSS base score

7.5

High severity

EPSS score (FIRST)

22.2%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2017-7924 · Source: NVD

CVSS v3.1 severity rating scale: None 0.0, Low 0.1 to 3.9, Medium 4.0 to 6.9, High 7.0 to 8.9, Critical 9.0 to 10.0
How a CVSS v3.1 base score maps to a severity rating. Source: FIRST CVSS v3.1 specification, section 5.

Affected components

ComponentCPEVersion range
Rockwell Automation MicroLogix 1100 1763-L16BWAcpe:2.3:o:rockwellautomation:1763-l16bwa_firmware:-:*:*:*:*:*:*:*firmware before FRN 16.0; update to FRN 16.0 or later (CISA ICSA-17-138-03)
Rockwell Automation MicroLogix 1100 1763-L16AWAcpe:2.3:o:rockwellautomation:1763-l16awa_firmware:-:*:*:*:*:*:*:*firmware before FRN 16.0; update to FRN 16.0 or later (CISA ICSA-17-138-03)
Rockwell Automation MicroLogix 1100 1763-L16BBBcpe:2.3:o:rockwellautomation:1763-l16bbb_firmware:-:*:*:*:*:*:*:*firmware before FRN 16.0; update to FRN 16.0 or later (CISA ICSA-17-138-03)
Rockwell Automation MicroLogix 1100 1763-L16DWDcpe:2.3:o:rockwellautomation:1763-l16dwd_firmware:-:*:*:*:*:*:*:*firmware before FRN 16.0; update to FRN 16.0 or later (CISA ICSA-17-138-03)

What does this mean for affected devices?

NVD describes CVE-2017-7924 as "an Improper Input Validation issue" in "Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L16AWA, 1763-L16BBB, and 1763-L16DWD. A remote, unauthenticated attacker could send a single, specially crafted Programmable Controller Communication Commands (PCCC) packet to the controller that could potentially cause the controller to enter a DoS condition." NVD's Primary score is CVSS v3.0 7.5 (high), vector CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H; its Primary CVSS v2 score is 5.0, AV:N/AC:L/Au:N/C:N/I:N/A:P. NVD and CISA both classify the weakness as CWE-20, Improper Input Validation. NVD published the record on 2017-09-20 and lists the firmware of all four catalogue numbers as vulnerable (NVD, CVE record).

What is affected?

CISA's advisory ICSA-17-138-03, first released on 18 May 2017 and updated as Update A on 18 July 2017, covers four MicroLogix 1100 controllers: 1763-L16DWD, 1763-L16BWA, 1763-L16AWA and 1763-L16BBB. It lists the products as deployed worldwide. The impact is availability only: the CVSS vector has no confidentiality or integrity impact, but a PLC that stops answering stops the machine or process it runs. CISA scores the issue with the same CVSS v3 7.5 and vector as NVD (CISA CSAF advisory).

CISA credits Mark Gondree of Sonoma State University, and Francisco Tacliad and Thuy Nguyen of the Naval Postgraduate School, with reporting the flaw. CVE-2017-7924 is the only vulnerability in ICSA-17-138-03.

How do you fix CVE-2017-7924?

Update the controller firmware. In CISA's words, "Rockwell Automation recommends updating to the latest firmware revision of MicroLogix 1100 controllers, Version FRN 16.0 or later." CISA points to Rockwell's knowledge-base article 1047342 for more detailed mitigation instructions; that article requires a Rockwell sign-in, so this page relies on the CISA advisory. CISA's recommended practices for the advisory ask organisations to do an impact analysis and risk assessment before deploying defensive measures, and point to its defence-in-depth guidance for control systems. A MicroLogix 1100 that cannot be updated at once should only be reachable from the engineering workstations and HMIs that need it.

How does it relate to other MicroLogix flaws?

The MicroLogix 1100 appears again in CVE-2021-33012, where crafted commands make the PLC fault whenever it is switched to RUN mode, and the MicroLogix 1400 in CVE-2021-22659, a Modbus parsing overflow that also ends in a denial of service. For Rockwell's larger controller family and the hardening steps Rockwell gives, see the Rockwell Logix controller guide; network-level controls for Rockwell plant networks are in the EtherNet/IP and CIP security guide. The developer-side fix pattern for malformed-input crashes is in the input handling fix guide.

Is CVE-2017-7924 exploited?

CVE-2017-7924 is not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25). FIRST EPSS gives it 0.222, the 98th percentile, in the 2026-11-26 dataset, read on 2026-11-27 (CISA KEV, FIRST EPSS). To weigh that probability against KEV status, see the KEV and EPSS prioritization guide.

Three signals on every advisory: CVSS says how severe the flaw is, EPSS gives the probability of exploitation in the wild in the next 30 days, and a CISA KEV listing means the flaw has been exploited in the wild
CVSS rates severity, EPSS estimates the likelihood of exploitation, and CISA KEV records exploitation seen in the wild. Source: FIRST EPSS; CISA KEV catalog.
How to fix this class of issueNo dedicated SoftWSP guide covers this weakness class; the fix is usually the vendor patch or firmware update referenced above. Our related guide explains how to plan and verify it: NIST SP 800-40 Rev. 4: enterprise patch management planning, explained.
From advisory to verified fix in four steps: read the advisory, find the affected component in the firmware SBOM, apply the fixed version or vendor mitigation, then re-scan the image to confirm the vulnerable version is gone
Read the advisory, find the component in your firmware SBOM, apply the fix, then re-scan to confirm it.

Evidence

  • Improper input validation in MicroLogix 1100 1763-L16BWA, -L16AWA, -L16BBB, -L16DWD; one crafted PCCC packet may cause DoS; NVD Primary CVSS v3.0 7.5, CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H; Primary v2 5.0; CWE-20; published 2017-09-20. — NVD
  • ICSA-17-138-03 released 18 May 2017, Update A 18 July 2017; four 1763 catalogue numbers affected; CISA CVSS v3 7.5 with the same vector; CWE-20; fix is firmware FRN 16.0 or later; credits Mark Gondree (Sonoma State University), Francisco Tacliad and Thuy Nguyen (Naval Postgraduate School). — CISA ICSA-17-138-03 (CSAF)
  • CVE record assigned by ICS-CERT (CNA icscert), CWE-20, published 2017-09-20. — CVE.org
  • Not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25). — CISA KEV
  • EPSS 0.222 (98th percentile), dataset 2026-11-26, read 2026-11-27. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CVE record
  3. CISA ICS Advisory ICSA-17-138-03: Rockwell Automation MicroLogix 1100 Controllers (Update A)
  4. CISA CSAF advisory ICSA-17-138-03
  5. CISA KEV
  6. FIRST EPSS

Frequently asked questions

Which MicroLogix controllers are affected by CVE-2017-7924?

The MicroLogix 1100 catalogue numbers 1763-L16BWA, 1763-L16AWA, 1763-L16BBB and 1763-L16DWD, running firmware older than FRN 16.0 (per NVD and CISA ICSA-17-138-03).

How do I fix CVE-2017-7924?

Update the MicroLogix 1100 firmware to FRN 16.0 or later, which is Rockwell Automation's recommendation as published by CISA. CISA also asks for an impact analysis and risk assessment before deploying defensive measures, and refers to its defence-in-depth recommended practices (per CISA ICSA-17-138-03).

Can an attacker steal data or change the program through CVE-2017-7924?

The scored impact is availability only. Both NVD and CISA give CVSS v3 7.5 with no confidentiality or integrity impact, `AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H`: a single crafted PCCC packet can stop the controller, which stops the process it controls (per NVD and CISA ICSA-17-138-03).

Is CVE-2017-7924 in the CISA KEV catalog?

No, not as of 2026-11-27 (catalog version 2026.11.25). FIRST EPSS gives it 0.222, the 98th percentile, in the 2026-11-26 dataset (per CISA KEV and FIRST EPSS).