CVE-2014-2363 is a set of hard-coded administrative credentials in the Morpho Itemiser 3, an explosive residue detector used by security screening staff. Version 8.17 is affected. A remote attacker who knows the credentials can log in, read and write the file system and reconfigure the device. NVD and CISA both score it 10.0, and Morpho chose not to fix it.
Vulnerability summary
CVSS base score
10
Critical severity
EPSS score (FIRST)
2.1%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2014-2363 · Source: NVD

Affected components
| Component | CPE | Version range |
|---|---|---|
| Morpho Itemiser 3 explosives trace detector | cpe:2.3:h:morpho:itemiser_3:8.17:*:*:*:*:*:*:* | Version 8.17 (NVD CPE and CISA ICSA-14-205-01); no fixed version released, the vendor chose not to address it |
What does this mean for affected devices?
The CVE record says Morpho Itemiser 3 version 8.17 "has hardcoded administrative credentials, which makes it easier for remote attackers to obtain access via a login request." CISA, which assigned the CVE, files it under CWE-259, use of a hard-coded password; NVD's own entry lists NVD-CWE-Other (NVD, CVE record).
How severe is CVE-2014-2363?
NVD's Primary score is CVSS v2 10.0, AV:N/AC:L/Au:N/C:C/I:C/A:C, the same score and vector CISA gives in the CVE record; NVD has no CVSS v3 score for this CVE. The vector reads: reachable over the network, low complexity, no authentication, and complete loss of confidentiality, integrity and availability. CISA's ICSA-14-205-01 adds that once access is gained, "the attacker can read and write to the file system and reconfigure the device", and could potentially reach devices connected to it. CISA credits independent researchers Billy Rios and Terry McCorkle and says an attacker with low skill could exploit it.
Which devices are affected and is there a fix?
CISA and NVD name only the Itemiser 3 at version 8.17. CISA describes it as an explosive residue detection device used by security personnel. The mitigation section of the advisory is one sentence from the vendor: "Morpho has decided not to address this vulnerability at this time." With no fixed version to install, CISA's general network advice is the whole mitigation: keep the detector off the internet, behind a firewall and apart from the business network, and allow remote access only over an up-to-date VPN. In practice the detector's network port should reach only the systems that collect its results, and any device that has been on an open network should be treated as one whose settings may have been changed.
The hard-coded credentials fix guide covers how fixed passwords are removed from device firmware, and the KEV and EPSS prioritization guide covers ranking unfixed devices. Related pages: CVE-2014-5422, a hard-coded service password in CareFusion Pyxis SupplyStation cabinets that Billy Rios also reported in 2014, and CVE-2016-2310, hard-coded credentials in GE MultiLink switches.
Is CVE-2014-2363 exploited?
CVE-2014-2363 is not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries), and CISA's advisory noted no known public exploit targeting it. FIRST EPSS gives it 0.02063, the 82.01th percentile, in the 2026-11-26 dataset (CISA KEV, FIRST EPSS).


Evidence
- NVD (read 2026-11-27): status Modified; published 2014-07-26; NVD Primary CVSS v2 10.0 AV:N/AC:L/Au:N/C:C/I:C/A:C; no CVSS v3; NVD CWE NVD-CWE-Other, CNA CWE-259; CPE morpho:itemiser_3:8.17 (hardware). — NVD
- CISA ICSA-14-205-01 CSAF (read 2026-11-27): Itemiser 3 v8.17; CWE-259; CVSS v2 10.0; remediation "Morpho has decided not to address this vulnerability at this time." — CISA ICSA-14-205-01
- CISA advisory page (read 2026-11-27 via a page fetch): researchers Billy Rios and Terry McCorkle; attacker can read and write the file system and reconfigure the device; explosive residue detection device used by security personnel; remotely exploitable; no known public exploits; low skill. — CISA
- CVE.org record via the CVE Services API (read 2026-11-27): CNA ICS-CERT; CVSS v2 10.0 AV:N/AC:L/Au:N/C:C/I:C/A:C; CWE-259; product Itemiser 3. — CVE.org
- Not in the CISA KEV catalog, catalog version 2026.11.25, 1,805 entries, checked 2026-11-27. — CISA KEV
- EPSS 0.02063, percentile 0.82013, dataset 2026-11-26, read 2026-11-27. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Is there a firmware update for CVE-2014-2363?
No. CISA ICSA-14-205-01 quotes the vendor: "Morpho has decided not to address this vulnerability at this time." Owners have to rely on network isolation: no internet exposure, a firewall in front of the detector and VPN-only remote access.
What can an attacker do with the hard-coded credentials?
Per CISA, log in remotely, read and write the file system and reconfigure the detector, and potentially reach devices connected to it. No user interaction or account of the attacker's own is needed.
Which Itemiser 3 versions are affected?
NVD and CISA name version 8.17. Neither source lists other affected or fixed versions, so any Itemiser 3 still in service should be treated as exposed unless Morpho's support says otherwise.
Is CVE-2014-2363 in the CISA KEV catalog?
No, not as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS rates it 0.02063 (82.01th percentile) in the 2026-11-26 dataset.