CVE-2013-5944: SCALANCE X-200 Web Server Auth Bypass

Last updated:
  • CVE-2013-5944

CVE-2013-5944 is an authentication flaw in the web server of Siemens SCALANCE X-200 and X-200IRT industrial Ethernet switches: anyone who can reach the web interface can run administrative operations without logging in. NVD scores it 10.0 under CVSS v2 and Siemens 9.8 under v3.1. Firmware V4.5.0 (X-200) and V5.1.0 (X-200IRT) fix it.

Vulnerability summary

CVSS base score

10

Critical severity

EPSS score (FIRST)

3.2%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2013-5944 · Source: NVD

Affected components

ComponentCPEVersion range
SCALANCE X-200 switch family (incl. SIPLUS NET variants)cpe:2.3:o:siemens:scalance_x-200_series_firmware:*:*:*:*:*:*:*:*All versions before V4.5.0; fixed in V4.5.0 (Siemens SSA-176087)
SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)cpe:2.3:o:siemens:scalance_x-200_series_firmware:*:*:*:*:*:*:*:*All versions before V5.1.0; fixed in V5.1.0 (Siemens SSA-176087)

What does this mean for affected devices?

NVD describes it this way: "The integrated web server on Siemens SCALANCE X-200 switches with firmware before 4.5.0 and X-200IRT switches with firmware before 5.1.0 does not properly enforce authentication requirements, which allows remote attackers to perform administrative actions via requests to the management interface." NVD's Primary score is CVSS v2 10.0 (AV:N/AC:L/Au:N/C:C/I:C/A:C) with CWE-287 (improper authentication). NVD has no v3 score for this 2013 record. The record was published on 2013-10-03 with MITRE as the assigning CNA (NVD, CVE record).

How severe is CVE-2013-5944?

Siemens rescored the advisory with CVSS v3.1 when it updated it on 2020-02-10: 9.8 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C), classed CWE-952 (missing authentication) (Siemens SSA-176087). Both scores describe the same case: no credentials, no user interaction, and full control of the switch configuration from any host that can open the web management page. Siemens credits Eireann Leverett of IOActive for coordinated disclosure.

CVE-2013-5944 is not in the CISA KEV catalog as of 2026-11-21 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.03203, the 88.4th percentile, in the 2026-11-20 dataset (CISA KEV, FIRST EPSS).

Which switches are affected?

Product (Siemens wording) Affected Fixed
SCALANCE X-200 switch family (incl. SIPLUS NET variants) before V4.5.0 V4.5.0
SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) before V5.1.0 V5.1.0

Siemens describes SCALANCE X switches as used to connect industrial components such as PLCs and HMIs. The SIPLUS NET variants were added to the advisory after Artem Zinenko of Kaspersky pointed out that they use the same firmware. NVD's CPE list uses one firmware product, scalance_x-200_series_firmware, with ranges up to 4.4 and up to 5.0.1, alongside the X-200 and X-200IRT hardware entries (Siemens SSA-176087 text).

How do you fix or mitigate it?

Update X-200 switches to V4.5.0 or later and X-200IRT switches to V5.1.0 or later. SSA-176087 recommended the then-current V5.0.1 (X-200) and V5.1.2 (X-200IRT). Later SCALANCE X-200 advisories, such as the web server overflows CVE-2021-25668 and CVE-2021-25669, require newer firmware still. Siemens lists no specific workaround for CVE-2013-5944. Its general advice is to protect network access to the device, which here means allowing the web management interface only from the engineering workstation or a management VLAN. Switches still on 2013-era firmware also carry the Telnet flaw CVE-2019-10942, which is fixed only in V5.2.5 (X-200) and V5.5.0 (X-200IRT).

Our SCALANCE and RUGGEDCOM vulnerability guide covers the X-200 line across all its advisories, and the authentication bypass fix guide explains this class of bug.

How to fix this class of issueThis advisory's weakness class is Authentication bypass. Our practical guide covers how to detect, fix, verify and disclose it: How to fix authentication bypass in embedded firmware.

Evidence

  • NVD (read 2026-11-21): status Modified; published 2013-10-03; NVD Primary CVSS v2 10.0 AV:N/AC:L/Au:N/C:C/I:C/A:C; no CVSS v3 metric; CWE-287; CPE scalance_x-200_series_firmware up to and including 4.4 and up to and including 5.0.1, version 4.3, with hardware scalance_x-200 and scalance_x-200irt; references SSA-176087. — NVD
  • Siemens SSA-176087 version 1.2 (published 2013-10-01, updated 2020-02-10), read 2026-11-21: web server authentication flaw lets attackers perform administrative operations over the network without authentication; X-200 (incl. SIPLUS NET) fixed in V4.5.0, X-200IRT (incl. SIPLUS NET) fixed in V5.1.0; recommends V5.0.1 and V5.1.2; CVSS v3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C; CWE-952; no specific workarounds; credits Eireann Leverett (IOActive) and Artem Zinenko (Kaspersky, SIPLUS mention). — Siemens ProductCERT SSA-176087
  • CVE record (checked 2026-11-21): state PUBLISHED, assigner MITRE, published 2013-10-03; no CNA CVSS metric or CWE. — CVE.org
  • Not in the CISA KEV catalog, version 2026.11.20 (1,790 entries), checked 2026-11-21. — CISA KEV
  • EPSS 0.03203, percentile 0.88446, dataset 2026-11-20, read 2026-11-21. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. Siemens ProductCERT SSA-176087: Unauthenticated Access to Critical Services in SCALANCE X-200 Switch Family
  3. Siemens ProductCERT SSA-176087 (signed text version)
  4. CVE.org record CVE-2013-5944
  5. CISA KEV
  6. FIRST EPSS

Frequently asked questions

Which firmware fixes CVE-2013-5944?

V4.5.0 for the SCALANCE X-200 switch family and V5.1.0 for the X-200IRT family, including SIPLUS NET variants, per Siemens SSA-176087. Later X-200 advisories require newer firmware, so update to the current release rather than the minimum.

What can an attacker do with it?

Perform administrative operations through the switch's web server without logging in, according to NVD and Siemens. On a managed industrial switch, that covers the device configuration, so both scores rate confidentiality, integrity and availability impact at the top level.

Is there a workaround?

Siemens lists no specific workaround for CVE-2013-5944. Its general recommendation is to protect network access to the device. Allow the web management interface only from a trusted engineering host or management VLAN until the switch runs fixed firmware.