CVE-2025-3394 is a user management bypass in ABB Automation Builder, the engineering tool for AC500 PLCs: user management data lives in the project file, and crafted changes to that file can overrule it. NVD and ABB score it 7.8. Setting the project's Security option to "Integrity check", the default from Automation Builder 2.8.1, prevents it.
Vulnerability summary
CVSS base score
7.8
High severity
EPSS score (FIRST)
0.2%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2025-3394 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| ABB Automation Builder | cpe:2.3:a:abb:automation_builder:*:*:*:*:*:*:*:* | through 2.8.0; 2.8.1 and later fixed with the default 'Integrity check' setting (ABB 3ADR011407, CISA ICSA-25-133-04, NVD up to and including 2.8.0) |
What does this mean for affected devices?
NVD carries ABB's description: "Incorrect Permission Assignment for Critical Resource vulnerability in ABB Automation Builder. This issue affects Automation Builder: through 2.8.0." NVD's Primary score and ABB's CVSS v3.1 score are both 7.8 (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H); ABB also gives CVSS v4.0 8.5. The CWE is CWE-732, from ABB. The record was published on 2025-04-30 (NVD, CVE record).
What goes wrong in the project file?
Automation Builder is ABB's programming and commissioning tool, mainly for AC500 PLCs and CP600 operator panels. ABB's advisory 3ADR011407 (revision B, 2025-07-25) explains that it "stores all user management information in the project file. Despite fully encrypted password data, an attacker could try to modify parts of the Automation Builder project file by specially crafted contents so that the user management will be overruled." The attacker needs file-level access to the project, which is why the vector is local. Jiho Shin of Sungkyunkwan University reported it; ABB knew of no exploitation.
Which versions are affected and how is it closed?
ABB says all Automation Builder versions are affected and closes the gap with a project setting: under "Project" → "Project Settings…" → "Security", set "Integrity check". This prevents anyone from accessing or modifying the content of the project file, and projects can still be opened and used without limits. From Automation Builder 2.8.1, "Integrity check" is the default, so keeping that default prevents CVE-2025-3394. CISA's ICSA-25-133-04 (Update A, 2026-05-21) lists Automation Builder 2.8.0 and earlier as affected and 2.8.1 and later as fixed; NVD's CPE covers versions up to and including 2.8.0.
Projects created in older versions keep their own setting, so check "Security" in every project you open, not only new ones. Store project files where only the engineering team can write to them.
The sibling CVE-2025-3395 attacks the AC500 V2 and SM560-S application files inside the same project and needs the "Encryption" setting instead. For a controller-side view of unprotected logic, see CVE-2022-31207 on Omron PLCs. See the ABB AC500, RTU500 and Relion guide and the authentication bypass fix guide.
CVE-2025-3394 is not in the CISA KEV catalog as of 2026-11-23 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.00151, the 4.3rd percentile, in the 2026-11-22 dataset (CISA KEV, FIRST EPSS).
Evidence
- NVD (read 2026-11-23): status Analyzed; published 2025-04-30; NVD Primary CVSS v3.1 7.8 AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H; ABB Secondary v3.1 7.8 and v4.0 8.5; CWE-732 (ABB); CPE abb:automation_builder up to and including 2.8.0. — NVD
- ABB 3ADR011407 rev B 2025-07-25 (initial 2025-04-30), PDF read 2026-11-23: all Automation Builder versions affected by CVE-2025-3394 and CVE-2025-3395; workarounds: project setting 'Security' = 'Integrity check' (3394), 'Encryption' (3395, authorized users can still open the project and exploit it); from 2.8.1 the default is 'Integrity check', which prevents CVE-2025-3394; exploitation needs file-level access to the project; responsible disclosure, no exploitation known; Automation Builder is the programming tool mainly for AC500 PLCs and CP600 panels. — ABB 3ADR011407
- CISA ICSA-25-133-04 Update A (2025-05-13, updated 2026-05-21), CSAF read 2026-11-23: known_affected Automation Builder <= 2.8.0, fixed >= 2.8.1 for both CVEs; CWE-732; CVSS v3.1 7.8 (3394) and 7.1 (3395). — CISA ICSA-25-133-04
- CVE record (checked 2026-11-23): state PUBLISHED, CNA ABB, published 2025-04-30; Automation Builder through 2.8.0; credit Jiho Shin, Sungkyunkwan University; CNA CVSS v4.0 8.5, v3.1 7.8. — CVE.org
- Not in the CISA KEV catalog, catalog version 2026.11.20, 1,790 entries, checked 2026-11-23. — CISA KEV
- EPSS 0.00151, percentile 0.04255, dataset 2026-11-22, read 2026-11-23. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
How do I close CVE-2025-3394 in Automation Builder?
Open "Project" → "Project Settings…" → "Security" and set "Integrity check". From Automation Builder 2.8.1 this is the default for the setting; ABB says keeping it prevents exploitation.
Is updating to Automation Builder 2.8.1 enough?
CISA lists 2.8.1 and later as fixed. ABB ties the fix to the "Integrity check" default, so check the Security setting of existing projects as well.
Can CVE-2025-3394 be exploited over the network?
The CVSS vector is local: the attacker needs access to the project file at file level, for example on a shared drive or an engineering PC.
Is CVE-2025-3394 in the CISA KEV catalog?
No, not as of 2026-11-23 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS rates it 0.00151 (4.3rd percentile) in the 2026-11-22 dataset.
Questions about this page?