  • CVE-2024-7502

CVE-2024-7502 is a stack-based buffer overflow in Delta Electronics DIAScreen engineering software. If an engineer opens a crafted DPA file, the attacker's code can run on that workstation with the engineer's rights. NVD and CISA score it 7.8. All versions before 1.4.2 are affected, and DIAScreen 1.4.2 fixes it.

Vulnerability summary

CVSS base score

7.8

High severity

EPSS score (FIRST)

0.4%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2024-7502 · Source: NVD

Affected components

ComponentCPEVersion range
Delta Electronics DIAScreencpe:2.3:a:deltaww:diascreen:*:*:*:*:*:*:*:*before 1.4.2; fixed in 1.4.2 (CISA ICSA-24-219-01, NVD before 1.4.2); later file-parsing CVEs fixed in v1.6.1 (Delta-PCSA-2025-00018)

What does this mean for affected devices?

NVD carries CISA's description: "A crafted DPA file could force Delta Electronics DIAScreen to overflow a stack-based buffer, which could allow an attacker to execute arbitrary code." NVD's Primary score and CISA's score are both CVSS v3.1 7.8 (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H); CISA also gives CVSS v4 8.5. CISA maps it to CWE-121, stack-based buffer overflow, and NVD adds CWE-787. The record was published on 2024-08-06 (NVD, CVE record).

How is it exploited?

The attacker has to get an engineer to open a crafted DPA file in DIAScreen, so the vector is local with user interaction; CISA's ICSA-24-219-01 of 2024-08-06 states plainly that the flaw "is not exploitable remotely." The code runs with the engineer's rights on the engineering workstation. CISA lists Energy as the sector, credits Natnael Samson (@NattiSamson) working with Trend Micro's Zero Day Initiative, and says no known public exploitation specifically targeting the flaw had been reported to CISA.

Which DIAScreen version fixes it?

DIAScreen 1.4.2, which Delta published on the DIAStudio download site; CISA and NVD both list every version before 1.4.2 as affected. The same parser has had more bugs since: Delta's Delta-PCSA-2025-00018 of 2025-10-03 lists four out-of-bounds write CVEs, led by CVE-2025-59297, in all versions before v1.6.1. Install v1.6.1 or later rather than stopping at 1.4.2.

What else reduces the risk?

Open DIAScreen projects only from known sources, do not open project files that arrive as email attachments, and keep engineering workstations behind a firewall, apart from the business network. The Delta Electronics guide puts DIAScreen next to Delta's other HMI and PLC engineering tools, and the memory corruption fix guide explains the bounds checks that close this class of file-parsing bug. A related Delta engineering-tool flaw with the same weakness is CVE-2024-39880 in CNCSoft-G2.

CVE-2024-7502 is not in the CISA KEV catalog as of 2026-11-23 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.00424, the 37.4th percentile, in the 2026-11-22 dataset (CISA KEV, FIRST EPSS).

How to fix this class of issueThis advisory's weakness class is Memory corruption. Our practical guide covers how to detect, fix, verify and disclose it: How to fix memory corruption in embedded firmware.

Evidence

  • NVD (read 2026-11-23): status Analyzed; published 2024-08-06; NVD Primary CVSS v3.1 7.8 CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H; CISA Secondary v3.1 7.8 and v4 8.5; CWE-121 (CISA), CWE-787 (NVD); CPE deltaww diascreen before 1.4.2. — NVD
  • CISA ICSA-24-219-01 (2024-08-06), CSAF read 2026-11-23: DIAScreen <1.4.2, crafted DPA file stack overflow; vendor fix v1.4.2; sector Energy; not exploitable remotely; no known public exploitation; credit Natnael Samson (@NattiSamson) with Trend Micro ZDI. — CISA ICSA-24-219-01
  • CVE record (checked 2026-11-23): state PUBLISHED, CNA icscert, published 2024-08-06, affected < 1.4.2, solution v1.4.2 on diastudio.deltaww.com. — CVE.org
  • Delta-PCSA-2025-00018 (published 2025-10-03): DIAScreen versions prior to v1.6.1 affected by CVE-2025-59297 to 59300 (CWE-787); fix v1.6.1. — Delta Electronics
  • Not in the CISA KEV catalog, catalog version 2026.11.20, 1,790 entries, checked 2026-11-23. — CISA KEV
  • EPSS 0.00424, percentile 0.37448, dataset 2026-11-22, read 2026-11-23. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CISA ICSA-24-219-01: Delta Electronics DIAScreen
  3. CISA ICSA-24-219-01 CSAF (machine-readable advisory)
  4. Delta-PCSA-2025-00018: DIAScreen File Parsing Out-Of-Bounds Write
  5. CVE.org record CVE-2024-7502
  6. CISA KEV
  7. FIRST EPSS

Frequently asked questions

Can CVE-2024-7502 be exploited over the network?

No. CISA says it is not exploitable remotely: a user has to open a crafted DPA file in DIAScreen, which is why the CVSS vector is local with user interaction required.

Which DIAScreen version fixes CVE-2024-7502?

DIAScreen 1.4.2. Because Delta-PCSA-2025-00018 lists four later file-parsing CVEs in versions before v1.6.1, install v1.6.1 or later.

Who reported CVE-2024-7502?

Natnael Samson (@NattiSamson), working with Trend Micro's Zero Day Initiative, according to CISA ICSA-24-219-01.

Is CVE-2024-7502 in the CISA KEV catalog?

No, not as of 2026-11-23 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS rates it 0.00424 (37.4th percentile) in the 2026-11-22 dataset.