CVE-2024-39880 is a stack-based buffer overflow in Delta Electronics CNCSoft-G2 engineering software. If a user opens a malicious file, the attacker's code runs in the CNCSoft-G2 process. NVD scores it 8.8 and CISA 7.8. CISA lists version 2.0.0.5 as affected and, after its February 2025 update, recommends v2.1.0.20 or later.
Vulnerability summary
CVSS base score
8.8
High severity
EPSS score (FIRST)
0.7%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2024-39880 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| Delta Electronics CNCSoft-G2 | cpe:2.3:a:deltaww:cncsoft-g2:2.0.0.5:*:*:*:*:*:*:* | 2.0.0.5 (CISA ICSA-24-191-01, CVE record and NVD); CISA Update A recommends v2.1.0.20 or later; v2.1.0.27 fixes the later CVE-2025-47728 (Delta-PCSA-2025-00007) |
What does this mean for affected devices?
NVD carries CISA's description: "Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. If a target visits a malicious page or opens a malicious file an attacker can leverage this vulnerability to execute code in the context of the current process." The record was published on 2024-07-09 (NVD, CVE record).
Why do NVD and CISA score it differently?
NVD's Primary score is CVSS v3.1 8.8 with a network vector (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). CISA, the CNA, scores it 7.8 with a local vector (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H) and 8.4 in CVSS v4. CISA's advisory says these vulnerabilities "are not exploitable remotely": a user has to open a malicious file in Delta's CNCSoft-G2 engineering software. CISA maps the flaw to CWE-121, stack-based buffer overflow; NVD adds CWE-787.
What does CISA's advisory say?
CISA's ICSA-24-191-01 was first released on 2024-07-09 with four file-parsing CVEs, CVE-2024-39880 to CVE-2024-39883, all in CNCSoft-G2 2.0.0.5. Update A of 2025-02-18 added the heap overflow CVE-2025-22880 in versions up to 2.1.0.10 and raised the recommended fix to v2.1.0.20 or later for all five. CISA lists Critical Manufacturing and Energy as sectors, credits Bobby Gould and Fritz Sands of Trend Micro's Zero Day Initiative, and says no known public exploitation specifically targeting these flaws had been reported to CISA.
Which version should be installed?
The CVE record still carries the first advice, update to V2.1.0.10, and NVD's CPE data lists only version 2.0.0.5 as affected. Follow CISA's updated advice instead, and go further: Delta's Delta-PCSA-2025-00007 of 2025-06-04 lists CNCSoft-G2 V2.1.0.20 and prior as affected by the out-of-bounds write CVE-2025-47728 and fixes it in v2.1.0.27. Until the update is done, open project files only from trusted sources and keep the engineering PC off the business network. The Delta Electronics guide tracks the CNCSoft-G2 fix levels, and the memory corruption fix guide covers the bounds checks that prevent this class. A similar Delta file-parsing flaw is CVE-2024-7502 in DIAScreen.
CVE-2024-39880 is not in the CISA KEV catalog as of 2026-11-23 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.00738, the 55.5th percentile, in the 2026-11-22 dataset (CISA KEV, FIRST EPSS).
Evidence
- NVD (read 2026-11-23): status Modified; published 2024-07-09; NVD Primary CVSS v3.1 8.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H; CISA Secondary v3.1 7.8 AV:L and v4 8.4; CWE-121 (CISA), CWE-787 (NVD); CPE deltaww cncsoft-g2 2.0.0.5 only. — NVD
- CISA ICSA-24-191-01 (initial 2024-07-09; Update A 2025-02-18 added CVE-2025-22880 and fixed version), CSAF read 2026-11-23: CVE-2024-39880 to 39883 affect CNCSoft-G2 2.0.0.5, CVE-2025-22880 affects <=2.1.0.10; fix v2.1.0.20 or later; not exploitable remotely; sectors Critical Manufacturing, Energy; credit Bobby Gould, Fritz Sands (ZDI) and Natnael Samson; no known public exploitation. — CISA ICSA-24-191-01
- CVE record (checked 2026-11-23): state PUBLISHED, CNA icscert, published 2024-07-09, affected version 2.0.0.5, solution update to CNCSoft-G2 V2.1.0.10 or later. — CVE.org
- Delta-PCSA-2025-00007 (first published 2025-06-04): CNCSoft-G2 V2.1.0.20 and prior affected by CVE-2025-47728; fix v2.1.0.27 or later. — Delta Electronics
- Not in the CISA KEV catalog, catalog version 2026.11.20, 1,790 entries, checked 2026-11-23. — CISA KEV
- EPSS 0.00738, percentile 0.55477, dataset 2026-11-22, read 2026-11-23. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which CNCSoft-G2 version fixes CVE-2024-39880?
CISA's ICSA-24-191-01 Update A recommends v2.1.0.20 or later; the CVE record still shows the original advice of V2.1.0.10. Because Delta-PCSA-2025-00007 lists V2.1.0.20 and prior as affected by CVE-2025-47728, install v2.1.0.27 or later.
Can CVE-2024-39880 be exploited remotely?
CISA says no: a user has to open a malicious file or visit a malicious page. NVD's 8.8 score uses a network vector with user interaction, while CISA's 7.8 uses a local vector.
Which other CVEs are in the same CISA advisory?
CVE-2024-39881, CVE-2024-39882 and CVE-2024-39883 in CNCSoft-G2 2.0.0.5, and CVE-2025-22880 in versions up to 2.1.0.10, all scored 7.8 by CISA and fixed in v2.1.0.20.
Is CVE-2024-39880 in the CISA KEV catalog?
No, not as of 2026-11-23 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS rates it 0.00738 (55.5th percentile) in the 2026-11-22 dataset.