  • CVE-2024-3596

CVE-2024-3596, Blast-RADIUS, lets a man-in-the-middle between a RADIUS client and server forge an Access-Accept through an MD5 chosen-prefix collision when the Message-Authenticator attribute is not required. Industrial switches, routers, access points and protection relays that check logins over RADIUS are affected, including Siemens SCALANCE, RUGGEDCOM and SIPROTEC 5 devices and Hitachi Energy AFS series products.

Vulnerability summary

CVSS base score

9

Critical severity

EPSS score (FIRST)

14.9%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2024-3596 · Source: NVD

Affected components

ComponentCPEVersion range
RADIUS protocol implementations (RFC 2865) without mandatory Message-Authenticator; NVD names FreeRADIUScpe:2.3:a:freeradius:freeradius:*:*:*:*:*:*:*:*FreeRADIUS before 3.0.27 per NVD; other NVD entries: Broadcom Brocade SANnav, Fabric OS, SonicWall SonicOS
hostapd (w1.fi hostap project), RADIUS client for MAC address ACLcpe:2.3:a:w1.fi:hostapd:*:*:*:*:*:*:*:*only the RADIUS MAC ACL case, in theory (w1.fi 2024-1); WPA3-Enterprise EAP and RADIUS server roles not vulnerable; stricter checks in 2.11
Siemens SCALANCE, RUGGEDCOM and SINEC INS (497 entries)—e.g. SCALANCE W-700 802.11n before V6.6.0, RUGGEDCOM RS/RSG V5.X before V5.10.0, ROX before V2.17.0, SCALANCE M-800 before V8.2; no fix listed for SCALANCE W1748/W1788 M12 (Siemens SSA-723487)
Siemens SIPROTEC 5, SICAM Q100/Q200, CPCI85, Powerlink IP—SIPROTEC 5 before V10.0 (CP100 before V8.90), SICAM Q100 before V2.70, Q200 before V2.83, CPCI85 before V6.20, Powerlink IP before V4.23 (Siemens SSA-794185)
Hitachi Energy AFS, AFR and AFF series—all versions; enable the RADIUS server message authenticator option (CISA ICSA-25-350-03)
Schneider Electric Modicon and Connexium managed switches—all versions, only if the Message Authenticator option is disabled; default configuration not vulnerable (CISA ICSA-26-160-01)

What does this mean for affected devices?

CVE-2024-3596, named Blast-RADIUS, is a forgery attack on the RADIUS protocol. NVD's record says RADIUS under RFC 2865 "is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature". NVD scores it 9.0 under CVSS v3.1, vector CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H, weakness CWE-354 (NVD). CERT/CC's VU#456537, published on 2024-07-09, says the attacker can "forge an authentication response in cases where a Message-Authenticator attribute is not required or enforced".

The researchers' Blast-RADIUS site sets the scope: it affects "all RADIUS implementations using non-EAP authentication methods over UDP", while "EAP authentication methods are protected" because RFC 2869 requires a Message-Authenticator on those packets. Their short-term fix is for clients and servers to "always send and require Message-Authenticator attributes for all requests and responses". That makes the network access server the exposed embedded component: a switch, router or access point that checks an administrator login or port access against a RADIUS server with PAP or CHAP.

For hostapd the w1.fi 2024-1 advisory (2024-07-09) is reassuring. In the main WPA3-Enterprise case hostapd, as RADIUS client, "is not vulnerable to the attack" because it already requires a valid Message-Authenticator on EAP messages and on Access-Accept. Only RADIUS-based MAC address access control "might" be affected, "at least in theory", with minimal impact. Upstream still added stricter checks, among them commit 5809712 "RADIUS: Require Message-Authenticator attribute in MAC ACL cases", and the hostapd ChangeLog for v2.11 (2024-07-20) lists "use stricter validation for some RADIUS messages". NVD's configuration names FreeRADIUS before 3.0.27, Broadcom Brocade SANnav and Fabric OS and SonicWall SonicOS, not hostapd; the Debian tracker tracks only freeradius, vulnerable in bookworm (3.2.1+dfsg-4+deb12u1) and fixed in trixie (3.2.7+dfsg-1+deb13u2).

Industrial network vendors published long product lists. Siemens ProductCERT SSA-723487 (first published 2024-07-09, V11 of 2026-06-09, CISA ICSA-24-193-05) lists 497 product entries for SCALANCE, RUGGEDCOM and SINEC INS, where the SCALANCE or RUGGEDCOM device is the RADIUS client. Fixes include SCALANCE W-700 IEEE 802.11n V6.6.0, SCALANCE WAM/WUM V3.0.0, RUGGEDCOM RS and RSG switches V5.10.0 (V5.X lines) or V4.3.11 (V4.X lines), RUGGEDCOM ROX V2.17.0, SCALANCE M-800 and RUGGEDCOM RM1224 V8.2 and SCALANCE X-300 V4.1.9; SSA-723487 lists no fix for six SCALANCE W1748-1 and W1788 M12 entries and none available for 26 SCALANCE XM-400 and XR-500 entries. SSA-794185 (2025-05-13, V5 of 2026-10-13) covers SIPROTEC 5 protection relays (V10.0, or V8.90 for CP100 devices), SICAM Q100 and Q200 power meters (V2.70, V2.83), CPCI85 (V6.20) and Powerlink IP (V4.23). CISA ICSA-25-350-03 lists Hitachi Energy AFS, AFR and AFF series products, all versions, with the fix being the RADIUS server message authenticator option (radius server msgauth on AFS65x/67x), and ICSA-26-160-01 says Schneider Electric Modicon and Connexium managed switches are not vulnerable in the default configuration, only if the Message Authenticator option is disabled.

The CVE is not in the CISA KEV catalog as of 2026-11-16 (catalog version 2026.11.13), and FIRST EPSS gives it 0.14859, the 96.75th percentile, in the 2026-11-16 dataset (CISA KEV, FIRST EPSS). The EPSS score is high for an attack that needs a man-in-the-middle position on the RADIUS path, so rank it by whether RADIUS crosses an untrusted network.

To fix it, update RADIUS servers first, then configure them to require Message-Authenticator in every Access-Request, as Siemens advises, and install the device firmware named above. Keep RADIUS on a management network or VLAN, or move to RADIUS over TLS. Our hostapd and wpa_supplicant vulnerabilities guide covers hostapd's RADIUS use, including the later RADIUS Message-Authenticator advisory 2026-5, and our authentication bypass fix guide covers enforcing every authentication check in device firmware.

How to fix this class of issueNo dedicated SoftWSP guide covers this weakness class; the fix is usually the vendor patch or firmware update referenced above. Our related guide explains how to plan and verify it: NIST SP 800-40 Rev. 4: enterprise patch management planning, explained.

Evidence

  • RADIUS under RFC 2865 susceptible to response forgery via MD5 chosen-prefix collision; NVD CVSS v3.1 9.0 (AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H), CWE-354; CPEs FreeRADIUS < 3.0.27, Brocade SANnav, Fabric OS, SonicOS. — NVD
  • VU#456537 (2024-07-09): forgery possible where a Message-Authenticator attribute is not required or enforced. — CERT/CC VU#456537
  • Affects all RADIUS implementations using non-EAP authentication over UDP; EAP protected by RFC 2869 Message-Authenticator; mitigation: always send and require Message-Authenticator. — Blast-RADIUS researchers
  • w1.fi 2024-1 (2024-07-09): hostapd WPA3-Enterprise RADIUS client not vulnerable; MAC ACL case at least in theory; RADIUS server role not applicable; stricter validation commits. — w1.fi advisory 2024-1
  • hostapd v2.11 (2024-07-20): use stricter validation for some RADIUS messages. — hostapd ChangeLog
  • Debian: freeradius vulnerable in bookworm (3.2.1+dfsg-4+deb12u1), fixed in trixie (3.2.7+dfsg-1+deb13u2). — Debian Security Tracker
  • SSA-723487 V11 (2026-06-09): 497 product entries; fixes incl. W-700 V6.6.0, WAM/WUM V3.0.0, RUGGEDCOM V5.X V5.10.0/V4.X V4.3.11, ROX V2.17.0, M-800 V8.2, X-300 V4.1.9; no fix for 6 W1748/W1788 M12 entries, none available for 26 XM-400/XR-500 entries. — Siemens ProductCERT SSA-723487
  • SSA-794185 V5 (2026-10-13): SIPROTEC 5 V10.0 (CP100 V8.90), SICAM Q100 V2.70, Q200 V2.83, CPCI85 V6.20, Powerlink IP V4.23. — Siemens ProductCERT SSA-794185
  • Hitachi Energy AFS/AFR/AFF all versions; enable RADIUS server message authenticator option. — CISA ICSA-25-350-03
  • Schneider Electric Modicon/Connexium managed switches: default RADIUS configuration not vulnerable unless Message Authenticator option disabled. — CISA ICSA-26-160-01
  • Not in the CISA KEV catalog as of 2026-11-16 (catalog version 2026.11.13). — CISA KEV
  • EPSS 0.14859 (96.75th percentile), dataset 2026-11-16, read 2026-11-16. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CERT/CC VU#456537: RADIUS protocol susceptible to forgery attacks
  3. Blast-RADIUS (researchers' site)
  4. w1.fi security advisory 2024-1: hostapd and RADIUS protocol forgery attacks
  5. hostap commit 5809712: RADIUS: Require Message-Authenticator attribute in MAC ACL cases
  6. hostapd ChangeLog (hostap.git)
  7. Siemens ProductCERT SSA-723487: RADIUS Protocol Susceptible to Forgery Attacks, impact to SCALANCE, RUGGEDCOM and related products
  8. Siemens ProductCERT SSA-794185: RADIUS Protocol Susceptible to Forgery Attacks, impact to SIPROTEC, SICAM and related products
  9. CISA ICS advisory ICSA-25-350-03 (CSAF): Hitachi Energy AFS, AFR and AFF Series
  10. CISA ICS advisory ICSA-26-160-01 (CSAF): Schneider Electric Modicon Network Managed Switches
  11. Debian Security Tracker
  12. CISA KEV
  13. FIRST EPSS

Frequently asked questions

Is a WPA3-Enterprise access point running hostapd affected by CVE-2024-3596?

No for the normal EAP case. The w1.fi 2024-1 advisory says hostapd as RADIUS client "is not vulnerable" there because it already requires a valid Message-Authenticator. Only RADIUS-based MAC address access control might be affected, at least in theory, and hostapd 2.11 added stricter checks for it.

Should the RADIUS server or the network device be patched first for CVE-2024-3596?

The server. The Blast-RADIUS researchers advise upgrading RADIUS servers first, because server vendors added a Message-Authenticator to every response, then the network access servers. Siemens' mitigation is the same: make the server require Message-Authenticator in all Access-Requests and keep RADIUS on a separate network.

Which industrial products are affected by CVE-2024-3596?

Siemens SSA-723487 lists 497 SCALANCE, RUGGEDCOM and SINEC INS entries, and SSA-794185 covers SIPROTEC 5 relays, SICAM Q100/Q200 meters, CPCI85 and Powerlink IP. CISA advisories add Hitachi Energy AFS, AFR and AFF series products, and Schneider Electric Modicon and Connexium switches when the Message Authenticator option is disabled.

Is CVE-2024-3596 in the CISA KEV catalog?

No, not as of 2026-11-16 (catalog version 2026.11.13). FIRST EPSS gives it 0.14859, the 96.75th percentile, in the 2026-11-16 dataset (per CISA KEV and FIRST EPSS).