CVE-2023-26597: Honeywell C300 Buffer Overflow DoS

Last updated:
  • CVE-2023-26597

**CVE-2023-26597** is a buffer overflow in the Honeywell C300 controller, published on 2023-07-13: a specially crafted message sent to the controller can cause a denial of service. It affects C300 firmware in Experion PKS, Experion LX and PlantCruise before R520.2, which is the fix. NVD, Honeywell and CISA all score it 7.5.

Vulnerability summary

CVSS base score

7.5

High severity

EPSS score (FIRST)

0.6%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2023-26597 · Source: NVD

Affected components

ComponentCPEVersion range
Honeywell C300 controller firmwarecpe:2.3:o:honeywell:c300_firmware:*:*:*:*:*:*:*:*501.1 to 501.6 HF8, 510.1 to 510.2 HF12, 511.1 to 511.5 TCU3, 520.1 to 520.1 TCU4, 520.2 to 520.2 TCU2 (NVD CPE, CVE record)
Honeywell Experion PKS, Experion LX and PlantCruise—before R520.2 per CISA ICSA-23-194-06; update to R520.2

What does this mean for affected devices?

Honeywell, the CNA, describes "Controller DoS due to buffer overflow in the handling of a specially crafted message received by the controller", in a record titled "Controller DOS on sending error response". It scores the flaw CVSS 3.1 7.5 (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H), maps it to CWE-400, uncontrolled resource consumption, and lists C300 releases 501.1 to 501.6 HF8, 510.1 to 510.2 HF12, 511.1 to 511.5 TCU3, 520.1 to 520.1 TCU4, 520.2 to 520.2 TCU2 (CVE record).

NVD's Primary score is the same 7.5 vector. NVD maps it to CWE-787, out-of-bounds write, and its configuration lists C300 firmware with the same five ranges (NVD).

CISA's ICSA-23-194-06 of 2023-07-13 covers nine Experion CVEs reported by Armis in Experion PKS, Experion LX and PlantCruise before R520.2, and recommends R520.2 for all three, downloaded from Honeywell's support portal. It also asks users to limit access to authorised users and to keep backup files where only authorised users can reach them. Honeywell's product security page lists the advisory as Critical, covering nine CVEs in versions before R520.2. CISA's text reads "C300 could experience a denial-of-service condition due to a buffer overflow in the handling of a specially crafted message received by the controller", scored CVSS 3.0 7.5 with CWE-400.

A crashed C300 stops running its control strategy until it restarts or fails over to its redundant partner, so the practical risk is lost control of a process unit. Until controllers run a fixed release, limit which hosts can send messages to C300s and keep redundant controller pairs healthy.

CVE-2023-26597 is not in the CISA KEV catalog as of 2026-11-23 (catalog version 2026.11.20). FIRST EPSS gives it 0.0064, percentile 51.5, in the 2026-11-22 dataset (CISA KEV, FIRST EPSS).

Our Honeywell Experion and ControlEdge guide lists all nine CVEs from ICSA-23-194-06. CVE-2023-25770 and CVE-2023-24480 are other C300 denial-of-service flaws from it, and CVE-2023-25178 is the C300 firmware-integrity flaw.

How to fix this class of issueThis advisory's weakness class is Resource exhaustion. Our practical guide covers how to detect, fix, verify and disclose it: How to fix SQL injection, XSS, resource exhaustion and deserialization flaws in embedded firmware.

Evidence

Related advisories

Sources

  1. NVD
  2. CVE.org record
  3. CISA ICSA-23-194-06: Honeywell Experion PKS, LX and PlantCruise (CSAF)
  4. Honeywell product security notices
  5. CISA KEV
  6. FIRST EPSS

Frequently asked questions

Which C300 firmware does CVE-2023-26597 affect?

Honeywell's CVE record and NVD list C300 releases 501.1 to 501.6 HF8, 510.1 to 510.2 HF12, 511.1 to 511.5 TCU3, 520.1 to 520.1 TCU4 and 520.2 to 520.2 TCU2 (per the CVE record and NVD).

What happens when CVE-2023-26597 is exploited?

The C300 controller can stop responding, a denial of service. None of the sources describes data disclosure or code execution for this flaw (per the CVE record, NVD and CISA ICSA-23-194-06).

How do I fix CVE-2023-26597?

Update Experion PKS, Experion LX or PlantCruise to R520.2, downloaded from Honeywell's support portal; early R520.2 updates up to TCU2 are still in Honeywell's affected range, so check the update level (per CISA ICSA-23-194-06 and the CVE record).

Is CVE-2023-26597 exploited in the wild?

It is not in the CISA KEV catalog as of 2026-11-23 (catalog version 2026.11.20). FIRST EPSS gives it 0.0064, percentile 51.5, in the 2026-11-22 dataset (per CISA KEV and FIRST EPSS).