CVE-2022-2793 is a missing integrity check in Emerson Proficy Machine Edition 9.00 and earlier, the engineering software that programs PACSystems PLCs: once an SRTP session is open, its data packets are neither authenticated nor authorized. NVD scores it CVSS 7.8 and CISA 5.9. Emerson recommends the SRP-6a authentication that SRTP and SNP support.
Vulnerability summary
CVSS base score
7.8
High severity
EPSS score (FIRST)
0.2%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2022-2793 · Source: NVD

Affected components
| Component | CPE | Version range |
|---|---|---|
| Emerson Proficy Machine Edition | cpe:2.3:a:emerson:electric\'s_proficy:*:*:*:*:machine:*:*:* | Proficy Machine Edition 9.00 and earlier (CISA ICSA-22-228-06; NVD CPE up to and including 9.0.0); mitigation: SRP-6a authentication for SRTP and SNP sessions |
What does this mean for affected devices?
NVD's description says that Emerson Electric's Proficy Machine Edition version 9.00 and prior "has no authentication or authorization of data packets after establishing a connection for the SRTP protocol." NVD's Primary analysis scores it 7.8 (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H) and maps it to CWE-353 and CWE-345; its CPE covers Proficy Machine Edition up to and including 9.0.0 (NVD). CISA, the CNA, scored it 5.9 (CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H), a physical attack vector with no confidentiality impact (CVE record).
Which Proficy Machine Edition versions are affected?
CISA advisory ICSA-22-228-06 (CSAF), released on 2022-08-16, covers six Machine Edition flaws; this one affects version 9.00 and earlier, and the ZipSlip flaw CVE-2022-2788 reaches 9.80. CISA lists sectors from critical manufacturing and energy to water and wastewater, worldwide deployment and a US headquarters. Sharon Brizinov of Claroty Research reported the flaws. CISA's risk summary is that exploitation could allow hidden code execution on the connected PLC and malicious files moving from the PLC to workstations. It reported no known public exploits.
How do I fix CVE-2022-2793?
The advisory gives no fixed Machine Edition build for this flaw. Emerson's mitigation is that SRTP and SNP support cryptographically secure authentication with the SRP-6a protocol, which it recommends users turn on; affected devices support encrypted authentication for session setup and privilege escalation, and Emerson says more encryption features will follow. Practical steps:
- enable SRP-6a authentication on PLCs and in Machine Edition projects;
- program PLCs only from the trusted control network, never across untrusted segments;
- keep engineering workstations dedicated to PLC work, since the other flaws in this advisory travel between workstation and PLC.
A sibling flaw from the same advisory is the project folder permissions issue CVE-2022-2792, and CVE-2019-13524 is a PACSystems RX3i denial of service. The GE Proficy, CIMPLICITY and Historian guide covers Machine Edition next to the GE Proficy HMI products, and the authentication bypass fix guide covers unauthenticated protocol sessions.
Is CVE-2022-2793 exploited?
CVE-2022-2793 is not in the CISA KEV catalog as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS gives it 0.00177, the 4.31th percentile, in the 2026-11-27 dataset (CISA KEV, FIRST EPSS).


Evidence
- NVD (read 2026-11-28): status Modified; published 2022-08-19; NVD Primary CVSS v3.1 7.8 CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H; ICS-CERT Secondary 5.9 CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H; CWE-353, CWE-345; CPE emerson electric's_proficy (machine) up to and including 9.0.0. — NVD
- CISA ICSA-22-228-06 CSAF (released 2022-08-16, read 2026-11-28): Emerson Proficy Machine Edition <= 9.80 (CVE-2022-2793: 9.00 and prior); CWE-353; CVSS v3 5.9; mitigation: SRP-6a authentication for SRTP and SNP, encrypted authentication for session establishment and privilege escalation; reported by Sharon Brizinov, Claroty Research; no known public exploits; sectors listed; Worldwide; HQ United States. — CISA ICSA-22-228-06
- CVE record (read 2026-11-28): state PUBLISHED, assigner icscert, published 2022-08-19; affected Emerson Electric Proficy Machine Edition <= 9.00; CNA CVSS v3.1 5.9 AV:P; CWE-353. — CVE.org
- Not in the CISA KEV catalog, catalog version 2026.11.27, 1,808 entries, checked 2026-11-28. — CISA KEV
- EPSS 0.00177, percentile 0.04310, dataset 2026-11-27, read 2026-11-28. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Is there a Machine Edition update that fixes CVE-2022-2793?
CISA ICSA-22-228-06 names no fixed build for this flaw. Emerson's mitigation is to use the SRP-6a authentication that SRTP and SNP support.
What is SRTP?
SRTP is the protocol Proficy Machine Edition uses to talk to the PLC. CVE-2022-2793 means packets sent after the connection is set up are not authenticated or authorized.
Why are the NVD and CISA scores so far apart?
NVD scores a local attack with full confidentiality, integrity and availability impact (7.8). CISA scores a physical attack vector with no confidentiality impact (5.9). Use the higher score for planning.
Is CVE-2022-2793 in the CISA KEV catalog?
No, not as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS rates it 0.00177 (4.31st percentile) in the 2026-11-27 dataset.
Questions about this page?