Security Advisory

CVE-2021-38406: Delta DOPSoft 2 Project File Write (KEV)

Last updated:
  • CVE-2021-38406

CVE-2021-38406 is an out-of-bounds write in Delta Electronics DOPSoft 2, the Windows tool used to build screens for Delta DOP HMI panels. A crafted project file can run code on the engineering workstation when a user opens it. It is the only Delta CVE in CISA's KEV catalog as of 2026-11-23, and DOPSoft 2 will get no fix.

Vulnerability summary

CVSS base score

7.8

High severity

EPSS score (FIRST)

76.4%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

Yes

Listed as known exploited

Published

Vulnerability ID: CVE-2021-38406 · Source: NVD

Affected components

ComponentCPEVersion range
Delta Electronics DOPSoft 2 (HMI configuration software)cpe:2.3:a:deltaww:dopsoft:*:*:*:*:*:*:*:*2.00 through 2.00.07 (NVD); 2.00.07 and prior, end-of-life with no fix (CISA ICSA-21-252-02)

What does this mean for affected devices?

NVD carries the CISA description: DOPSoft 2 version 2.00.07 and prior "lacks proper validation of user-supplied data when parsing specific project files", which "could result in multiple out-of-bounds write instances" and lets an attacker "execute code in the context of the current process". NVD's Primary score is CVSS v3.1 7.8 (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H) and its CVSS v2 score is 6.8; CISA, the CNA, also scores 7.8 and maps the flaw to CWE-787. NVD's CPE covers DOPSoft 2.00 through 2.00.07 (NVD, CVE record).

What does CISA say about DOPSoft 2?

CISA's ICSA-21-252-02 of 2021-09-09 covers three file-parsing flaws in DOPSoft 2: this out-of-bounds write, the heap-based overflow CVE-2021-38404 and the stack-based overflow CVE-2021-38402, all scored 7.8. CISA notes the flaws are not exploitable remotely; the attack needs a user to open a malicious project file. DOPSoft 2 "will not receive an update" because it is end-of-life. Delta recommends moving HMI devices to the DOP-100 family and the software to DIAScreen in DIAStudio v1.1.2 or later.

Why is it in the KEV catalog?

CISA added CVE-2021-38406 to the KEV catalog on 2022-08-25 with a due date of 2022-09-15. The required action is that "the impacted product is end-of-life and should be disconnected if still in use"; known ransomware use is marked Unknown. KEV names it an improper input validation flaw that results in the out-of-bounds write. FIRST EPSS gives it 0.76428, the 99.5th percentile, in the 2026-11-22 dataset (FIRST EPSS).

What should operators do?

Find every laptop that still has DOPSoft 2 installed, migrate the panel projects to DIAScreen and remove DOPSoft 2. Until then, open only project files from a known source, and keep the workstation off the internet and away from email. The Delta Electronics guide lists the later DOPSoft and DIAScreen file-parsing CVEs, and the memory corruption fix guide explains this class of bug. Similar engineering-file attacks: CVE-2022-45788 in Modicon project files and CVE-2019-10996 in Red Lion Crimson.

How to fix this class of issueThis advisory's weakness class is Memory corruption. Our practical guide covers how to detect, fix, verify and disclose it: How to fix memory corruption in embedded firmware.

Evidence

  • NVD (read 2026-11-23): status Analyzed; published 2021-09-17; NVD Primary CVSS v3.1 7.8 AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H and CVSS v2 6.8 AV:N/AC:M/Au:N/C:P/I:P/A:P; ICS-CERT Secondary 7.8; CWE-787 (ICS-CERT); CPE deltaww dopsoft 2.00 to 2.00.07 inclusive. — NVD
  • CISA ICSA-21-252-02 CSAF (released 2021-09-09), read 2026-11-23: DOPSoft 2 version 2.00.07 and prior; CVE-2021-38402 (CWE-121), CVE-2021-38406 (CWE-787), CVE-2021-38404 (CWE-122), each CVSS v3 7.8; not exploitable remotely; end-of-life, no update; switch HMI to DOP-100 family and software to DIAScreen in DIAStudio v1.1.2 or later. — CISA ICSA-21-252-02
  • CVE record (checked 2026-11-23): state PUBLISHED, CNA ICS-CERT (icscert), published 2021-09-17, CNA CVSS v3.1 7.8, CWE-787. — CVE.org
  • In the CISA KEV catalog (catalog version 2026.11.20, 1,790 entries, checked 2026-11-23): dateAdded 2022-08-25, dueDate 2022-09-15, required action 'The impacted product is end-of-life and should be disconnected if still in use.', knownRansomwareCampaignUse Unknown. — CISA KEV
  • EPSS 0.76428, percentile 0.99549, dataset 2026-11-22, read 2026-11-23. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CISA ICSA-21-252-02: Delta Electronics DOPSoft 2 (CSAF)
  3. CVE.org record CVE-2021-38406
  4. CISA KEV
  5. FIRST EPSS

Frequently asked questions

Is there a patch for CVE-2021-38406?

No. CISA's ICSA-21-252-02 says DOPSoft 2 is end-of-life and will not receive an update. Delta recommends moving HMI devices to the DOP-100 family and the software to DIAScreen in DIAStudio v1.1.2 or later.

What does CISA KEV require for CVE-2021-38406?

CISA added it on 2022-08-25 with a due date of 2022-09-15 and the action that the end-of-life product should be disconnected if still in use. Ransomware use is marked Unknown (catalog version 2026.11.20, checked 2026-11-23).

Can it be exploited over the network?

Not directly. CISA says the DOPSoft 2 flaws are not exploitable remotely; an attacker has to get a user to open a crafted project file, for example one sent by email or copied from a shared drive.

Does it affect the DOP HMI panel itself?

The advisories name the DOPSoft 2 software on the engineering workstation, not panel firmware. The code runs on the PC where the project is opened, which is often the PC that later downloads projects to panels.