Security Advisory

CVE-2021-27462: FactoryTalk AssetCentre Deserialization

Last updated:
  • CVE-2021-27462

CVE-2021-27462 is a deserialization flaw in the AosService.rem service of Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier, the plant's archive for controller programs. The service does not verify serialized data properly, so a remote attacker without credentials may execute arbitrary commands on the AssetCentre server. NVD scores it 9.8 and CISA 10.0. AssetCentre v11 fixes it.

Vulnerability summary

CVSS base score

9.8

Critical severity

EPSS score (FIRST)

3.8%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2021-27462 · Source: NVD

CVSS v3.1 severity rating scale: None 0.0, Low 0.1 to 3.9, Medium 4.0 to 6.9, High 7.0 to 8.9, Critical 9.0 to 10.0
How a CVSS v3.1 base score maps to a severity rating. Source: FIRST CVSS v3.1 specification, section 5.

Affected components

ComponentCPEVersion range
Rockwell Automation FactoryTalk AssetCentrecpe:2.3:a:rockwellautomation:factorytalk_assetcentre:*:*:*:*:*:*:*:*v10.00 and earlier (NVD: up to and including 10.00; CISA ICSA-21-091-01); fixed in AssetCentre v11 and later

What does this mean for affected devices?

The CVE record reads: "A deserialization vulnerability exists in how the AosService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre." NVD's Primary score is 9.8 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, CVSS 2.0 7.5) with CWE-502. CISA's record score is CVSS 3.1 10.0 (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:H), and the CSAF file gives 10.0 with a CVSS 3.0 vector that also rates integrity high. NVD's configuration covers AssetCentre up to and including 10.00; the record was published on 2022-03-23 (NVD, CVE record).

Which AssetCentre versions are affected?

CISA's ICSA-21-091-01 (CSAF), released on 2021-04-01, lists FactoryTalk AssetCentre v10.00 and earlier, deployed worldwide in the Critical Manufacturing sector, and names Sharon Brizinov and Amir Preminger of Claroty as the reporters. The advisory holds nine CVE ids, all unauthenticated and all scored 10.0 by CISA: CVE-2021-27460, CVE-2021-27462, CVE-2021-27464, CVE-2021-27466, CVE-2021-27468, CVE-2021-27470, CVE-2021-27472, CVE-2021-27474 and CVE-2021-27476. Four are deserialization flaws in the product's .NET remoting services (CVE-2021-27460, CVE-2021-27466, CVE-2021-27470 and this one); CISA says CVE-2021-27460 may give "full access to the FactoryTalk AssetCentre main server and all agent machines." The SQL injection CVE-2021-27472 is in the same advisory.

How do you fix CVE-2021-27462?

Rockwell's fix, as CISA records it, is to update to FactoryTalk AssetCentre v11 or later; Rockwell's publication PN1559 (Knowledgebase, login required) describes the nine flaws. Owners who cannot upgrade at once, or who worry about unauthorized client connections, can turn on the product's built-in IPsec support following Rockwell's QA46277; Rockwell tested it on AssetCentre v9 to v11. CISA also lists Rockwell's general controls:

  • run the software as a normal user, not an administrator, and use application allow-listing such as Microsoft AppLocker (Rockwell QA17329);
  • give user and service accounts only the rights they need on shared resources such as the database;
  • keep control system networks off the internet and behind firewalls, isolated from the business network;
  • use an up-to-date VPN when remote access is needed.

The current AssetCentre line is V15; CISA's 2025 advisory ICSA-25-030-05 fixes a credential flaw, CVE-2025-0477, in V15.00.001, so a site leaving v10 should go straight to a current release.

The Rockwell FactoryTalk software guide covers the AssetCentre advisories alongside View, Linx and the FactoryTalk Services Platform. For where an AssetCentre server belongs in a small plant network, see the OT/ICS security guide for small manufacturers.

Is CVE-2021-27462 exploited?

CVE-2021-27462 is not in the CISA KEV catalog as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS gives it 0.0383, a percentile of 90.9, in the 2026-11-27 dataset (CISA KEV, FIRST EPSS). CISA reported no known public exploits specifically targeting these vulnerabilities when it published the advisory.

Three signals on every advisory: CVSS says how severe the flaw is, EPSS gives the probability of exploitation in the wild in the next 30 days, and a CISA KEV listing means the flaw has been exploited in the wild
CVSS rates severity, EPSS estimates the likelihood of exploitation, and CISA KEV records exploitation seen in the wild. Source: FIRST EPSS; CISA KEV catalog.
How to fix this class of issueThis advisory's weakness class is Insecure deserialization. Our practical guide covers how to detect, fix, verify and disclose it: How to fix SQL injection, XSS, resource exhaustion and deserialization flaws in embedded firmware.
From advisory to verified fix in four steps: read the advisory, find the affected component in the firmware SBOM, apply the fixed version or vendor mitigation, then re-scan the image to confirm the vulnerable version is gone
Read the advisory, find the component in your firmware SBOM, apply the fix, then re-scan to confirm it.

Evidence

  • NVD (read 2026-11-28): status Modified; published 2022-03-23; [email protected] Primary CVSS 3.1 9.8 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H and CVSS 2.0 7.5; ICS-CERT Secondary 10.0 S:C/C:H/I:N/A:H; CWE-502; CPE factorytalk_assetcentre up to and including 10.00. — NVD
  • CISA ICSA-21-091-01 CSAF (read 2026-11-28): released 2021-04-01; AssetCentre <= 10.00; CVE-2021-27462 CWE-502 in AosService.rem, CVSS 3.0 10.0; deserialization CVEs 27460, 27462, 27466, 27470; CVE-2021-27460 'full access to the FactoryTalk AssetCentre main server and all agent machines'; fix v11 or above (PN1559); IPsec per QA46277; reported by Claroty; no known public exploits. — CISA ICSA-21-091-01
  • CVE record (read 2026-11-28): PUBLISHED, assigner icscert, published 2022-03-23; AssetCentre <= v10.00; CWE-502; CNA CVSS 3.1 10.0; solutions v11 or above and IPsec per QA46277. — CVE.org
  • Not in the CISA KEV catalog, catalog version 2026.11.27, 1,808 entries, checked 2026-11-28. — CISA KEV
  • EPSS 0.03828, percentile 0.90864, dataset 2026-11-27, read 2026-11-28. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CISA ICSA-21-091-01: Rockwell Automation FactoryTalk AssetCentre
  3. CISA ICSA-21-091-01 CSAF (machine-readable advisory)
  4. CVE record CVE-2021-27462 (CVE Services JSON)
  5. CISA KEV
  6. FIRST EPSS

Frequently asked questions

Which FactoryTalk AssetCentre versions are affected by CVE-2021-27462?

AssetCentre v10.00 and earlier, per CISA ICSA-21-091-01, the CVE record and NVD's configuration (up to and including 10.00).

How do I fix CVE-2021-27462?

Upgrade to FactoryTalk AssetCentre v11 or later, preferably a current V15 release. Until then, enable the built-in IPsec support described in Rockwell QA46277, which Rockwell tested on v9 to v11, and allow only engineering hosts to reach the server.

Why does the AssetCentre server matter so much?

AssetCentre stores the master copies of controller projects and has agents on engineering machines. CISA's advisory says a sibling deserialization flaw, CVE-2021-27460, may give full access to the main server and all agent machines, so a compromise reaches well beyond one host.

Is CVE-2021-27462 in the CISA KEV catalog?

No, not as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS rates it 0.0383 (percentile 90.9) in the 2026-11-27 dataset.