CVE-2020-6989 is a stack-based buffer overflow in the web server of Moxa PT-7528 and PT-7828 rackmount Ethernet switches, which a remote attacker can use to crash the switch or run code on it. NVD scores it 9.8, CISA 10.0. Moxa provides a security patch through its Technical Support for both series.
Vulnerability summary
CVSS base score
9.8
Critical severity
EPSS score (FIRST)
3.5%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2020-6989 · Source: NVD

Affected components
| Component | CPE | Version range |
|---|---|---|
| Moxa PT-7528 Series | cpe:2.3:o:moxa:pt-7528-24tx-hv_firmware:*:*:*:*:*:*:*:* | Firmware 4.0 or lower (Moxa MPSA-190904, CISA ICSA-20-056-03, NVD CPEs for every PT-7528 model up to and including 4.0); security patch from Moxa Technical Support |
| Moxa PT-7828 Series | cpe:2.3:o:moxa:pt-7828-f-24_firmware:*:*:*:*:*:*:*:* | Firmware 3.9 or lower (Moxa, CISA, NVD CPEs for every PT-7828 model up to and including 3.9); security patch from Moxa Technical Support |
What does this mean for affected devices?
The CVE record from CISA says that in Moxa PT-7528 series firmware version 4.0 or lower and PT-7828 series firmware version 3.9 or lower, "a buffer overflow in the web server allows remote attackers to cause a denial-of-service condition or execute arbitrary code." NVD's Primary score is 9.8 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, CVSS 2.0 7.5) with CWE-787, out-of-bounds write. CISA scores it 10.0 (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H) and, like Moxa, classes it as CWE-121, stack-based buffer overflow; the CVE record carries no CVSS score (NVD, CVE record).
Which Moxa switches are affected?
Moxa's advisory MPSA-190904, version 1.0 of 25 September 2019, lists the PT-7528 Series at firmware 4.0 or lower and the PT-7828 Series at 3.9 or lower, and covers six CVEs. CISA published the same set as ICSA-20-056-03 on 2020-02-25, for the Critical Manufacturing, Energy and Water and Wastewater sectors, deployed worldwide. The siblings are a hard-coded password (CVE-2020-6985) and weak password requirements (CVE-2020-6995), both 9.8 on NVD, a hard-coded cryptographic key (CVE-2020-6983), a risky cryptographic algorithm (CVE-2020-6987) and information exposure (CVE-2020-6993), each 7.5 on NVD. NVD's CPE list names each PT-7528 and PT-7828 model variant separately. Ilya Karpov and Evgeniy Druzhinin of Rostelecom-Solar and Georgy Zaytsev of Positive Technologies reported the flaws.
How do you fix CVE-2020-6989?
Moxa's solution for both series is to contact Moxa Technical Support for a security patch. For the credential and cryptography siblings, Moxa recommends applying the patch and then enabling the Account Login Failure Lockout function. Until the patch is installed, CISA's advice is to keep the switch management interface off the internet, place it behind firewalls separated from business networks and use secure remote access. CISA published a companion advisory for Moxa EDS-G516E switches the same day (ICSA-20-056-04), see CVE-2020-6979, and our Moxa EDS/EDR switch guide tracks the family. For device makers, the memory corruption fix guide covers bounds checks in embedded web servers.
Is CVE-2020-6989 exploited?
CVE-2020-6989 is not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS gives it 0.03498, the 89.93th percentile, in the 2026-11-26 dataset (CISA KEV, FIRST EPSS). CISA reported no known public exploits specifically targeting these vulnerabilities.


Evidence
- NVD (read 2026-11-27): status Modified; published 2020-03-24; [email protected] Primary CVSS 3.1 9.8 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, CVSS 2.0 7.5; NVD CWE-787, ICS-CERT CWE-121; CPEs for every PT-7528 model firmware up to and including 4.0 and every PT-7828 model firmware up to and including 3.9. — NVD
- Moxa MPSA-190904 V1.0 (2019-09-25): six CVEs incl. CVE-2020-6989 stack-based buffer overflow (CWE-121); PT-7528 firmware 4.0 or lower, PT-7828 3.9 or lower; solution: contact Moxa Technical Support for a security patch; for vulnerabilities 2-5 apply the patch and enable Account Login Failure Lockout; credits Rostelecom-Solar and Positive Technologies. — Moxa
- CISA ICSA-20-056-03 (CSAF, 2020-02-25): CVE-2020-6989 CWE-121 CVSS 3.0 10.0 AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H; sectors Critical Manufacturing, Energy, Water and Wastewater; worldwide; no known public exploits. — CISA CSAF
- CVE record (CNA icscert, published 2020-03-24): PT-7528 firmware 4.0 or lower, PT-7828 3.9 or lower; no CNA CVSS. NVD Primary of siblings: CVE-2020-6985 9.8, -6995 9.8, -6983 7.5, -6987 7.5, -6993 7.5. — CVE.org
- CISA KEV catalog version 2026.11.25, 1,805 entries: CVE-2020-6989 not listed; checked 2026-11-27. — CISA KEV
- EPSS 0.03498, percentile 0.89926, dataset 2026-11-26, read 2026-11-27. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which Moxa firmware versions are affected by CVE-2020-6989?
PT-7528 Series firmware 4.0 or lower and PT-7828 Series firmware 3.9 or lower, per Moxa MPSA-190904, CISA ICSA-20-056-03 and NVD.
How do I get the fix for CVE-2020-6989?
Moxa delivers a security patch for both series through Moxa Technical Support; there is no public download named in the advisory. Moxa also recommends enabling Account Login Failure Lockout after patching.
Why do NVD and CISA score CVE-2020-6989 differently?
CISA scores it 10.0 with a changed scope (S:C); NVD's own analysis scores 9.8 with unchanged scope (S:U). Both rate it network-exploitable without authentication.