**CVE-2020-28895** is an integer overflow in the Wind River VxWorks memory allocator, published by NVD on 2021-02-03 with a CVSS v3.1 score of 7.3: calloc() can allocate less memory than requested, leading to memory corruption. GE Vernova's notice GES-2025-005 lists UR protection relay firmware 7.00 to 8.62 as affected and fixes it in UR firmware 8.70.
Vulnerability summary
CVSS base score
7.3
High severity
EPSS score (FIRST)
1.5%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2020-28895 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| Wind River VxWorks | cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:* | NVD: 6.9 up to (excluding) 6.9.4.12, plus 6.9.4.12 and 6.9.4.12 rolling cumulative patch layer 1 |
| GE Vernova UR relay firmware | — | 7.00 to 8.62; fixed in UR firmware 8.70 (per GE Vernova GES-2025-005) |
| Oracle Communications EAGLE (Software Measurements, VxWorks) | cpe:2.3:a:oracle:communications_eagle:*:*:*:*:*:*:*:* | 46.7.0, 46.8.0-46.8.2, 46.9.1-46.9.3 (per Oracle CPU April 2022) |
What does this mean for affected devices?
NVD's description reads: "In Wind River VxWorks, memory allocator has a possible overflow in calculating the memory block's size to be allocated by calloc(). As a result, the actual memory allocated is smaller than the buffer size specified by the arguments, leading to memory corruption" (NVD). NVD scores it 7.3 under CVSS v3.1 with vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L, records CWE-190 (integer overflow) and CWE-787 (out-of-bounds write), and its configuration covers VxWorks 6.9 up to 6.9.4.12, the 6.9.4.12 release and its rolling cumulative patch layer 1, plus Oracle Communications EAGLE.
GE Vernova's security notice GES-2025-005 (initial release 14 December 2025, revised 22 January 2026) lists CVE-2020-28895 against "UR IED Firmware versions 7.00 to 8.62" and states that UR firmware 8.70 addresses it "by applying patches provided by Wind River." GE Vernova's own assessment is cautious: "Our development team has identified no feasible exploit vectors, but the vulnerability was fixed as a preventative measure." The notice recommends UR firmware 8.70, released in November 2025, and EnerVista UR Setup 8.70 or greater, and at publication GE Vernova had no reports of attacks exploiting the vulnerabilities it covers.
The same allocator flaw reaches other VxWorks-based products. Oracle's April 2022 Critical Patch Update states that "the patch for CVE-2020-35198 also addresses CVE-2020-28895" in Oracle Communications EAGLE (Software Measurements, VxWorks), versions 46.7.0, 46.8.0-46.8.2 and 46.9.1-46.9.3. CISA's "Multiple RTOS" advisory ICSA-21-119-04 (CSAF) lists CVE-2020-28895 with "Windriver VxWorks" below 7.0 among its affected products; that CSAF entry's summary text describes a FreeRTOS flaw, so the description on this page comes from NVD.
CVE-2020-28895 is not in the CISA KEV catalog as of 2026-11-16 (catalog version 2026.11.13). FIRST EPSS gives it 0.015, percentile 75.4, in the 2026-11-16 dataset (CISA KEV, FIRST EPSS).
For a UR fleet, every relay from firmware 7.00 to 8.62 is in range regardless of order code, so the action is firmware 8.70 through the normal outage and protection-testing process. NVD's CPE data names VxWorks and Oracle EAGLE but no GE product, so a CPE-only scanner will not flag a UR relay. Our GE Vernova UR relay guide puts GES-2025-005 next to the earlier UR advisories, and the memory corruption fix guide covers allocator size checks. CVE-2020-10664 is the VxWorks IGMP flaw fixed in the same release, and CVE-2016-20009 is an older VxWorks IPnet flaw.
Evidence
- VxWorks memory allocator overflow when calculating calloc() block size leads to memory corruption; NVD Primary CVSS v3.1 7.3 (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L), v2 7.5; CWE-190, CWE-787; CPE VxWorks 6.9 to before 6.9.4.12, 6.9.4.12, 6.9.4.12 RCPL1, Oracle Communications EAGLE; published 2021-02-03. — NVD
- CVE-2020-28895 affects UR IED firmware 7.00 to 8.62; fixed in UR firmware 8.70 (released November 2025) with Wind River patches; GE found no feasible exploit vectors and fixed it as a preventative measure; no reported attacks at publication. — GE Vernova Security Notice GES-2025-005: UR IED and EnerVista UR Setup vulnerabilities fixed in version 8.70 (PDF)
- The patch for CVE-2020-35198 also addresses CVE-2020-28895; Oracle Communications EAGLE Software Measurements (VxWorks) 46.7.0, 46.8.0-46.8.2, 46.9.1-46.9.3. — Oracle Critical Patch Update Advisory, April 2022
- ICSA-21-119-04 (Update E, 2022-04-19) lists CVE-2020-28895 (CWE-190) with Windriver VxWorks < 7.0 among known affected products; entry summary text describes FreeRTOS. — CISA ICSA-21-119-04 (Update E): Multiple RTOS (CSAF)
- Not in the CISA KEV catalog as of 2026-11-16 (catalog version 2026.11.13). — CISA KEV
- EPSS 0.01542 (percentile 75.4), dataset 2026-11-16, read 2026-11-16. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which GE Vernova UR firmware versions are affected by CVE-2020-28895?
UR IED firmware 7.00 to 8.62; GE Vernova fixed it in UR firmware 8.70, released in November 2025 (per GE Vernova GES-2025-005).
Does GE Vernova consider CVE-2020-28895 exploitable on a UR relay?
GE Vernova states its development team "identified no feasible exploit vectors, but the vulnerability was fixed as a preventative measure" (per GE Vernova GES-2025-005).
Which other products does CVE-2020-28895 affect?
NVD lists Wind River VxWorks 6.9 releases and Oracle Communications EAGLE; Oracle's April 2022 Critical Patch Update names EAGLE Software Measurements versions 46.7.0, 46.8.0-46.8.2 and 46.9.1-46.9.3 (per NVD and Oracle).
Is CVE-2020-28895 in the CISA KEV catalog?
No, as of 2026-11-16 (catalog version 2026.11.13). FIRST EPSS gives it 0.015, percentile 75.4, in the 2026-11-16 dataset (per CISA KEV and FIRST EPSS).