CVE-2019-6520 is a missing server-side authorization check in the web interface of Moxa IKS-G6824A industrial Ethernet switches, which CISA and NVD also list for the EDS-405A, EDS-408A and EDS-510A: a user with a read-only account can change the switch configuration. NVD scores it 7.5, CISA 9.1. Moxa provides a patch firmware through its Technical Support.
Vulnerability summary
CVSS base score
7.5
High severity
EPSS score (FIRST)
1.7%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2019-6520 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| Moxa IKS-G6824A Series | cpe:2.3:o:moxa:iks-g6824a_firmware:*:*:*:*:*:*:*:* | Firmware 5.6 or lower (Moxa MCSA-190201 V1.2, CISA ICSA-19-057-01); CVE record and NVD CPE say 4.5 and prior. Fix: patch firmware from Moxa Technical Support |
| Moxa EDS-405A Series | cpe:2.3:o:moxa:eds-405a_firmware:*:*:*:*:*:*:*:* | Firmware 3.8 and prior (CISA ICSA-19-057-01, CVE record, NVD CPE; Moxa lists this CVE for the IKS-G6824A only). Fix: patch firmware from Moxa |
| Moxa EDS-408A Series | cpe:2.3:o:moxa:eds-408a_firmware:*:*:*:*:*:*:*:* | Firmware 3.8 and prior (CISA ICSA-19-057-01, CVE record, NVD CPE). Fix: patch firmware from Moxa |
| Moxa EDS-510A Series | cpe:2.3:o:moxa:eds-510a_firmware:*:*:*:*:*:*:*:* | Firmware 3.8 and prior (CISA ICSA-19-057-01, CVE record, NVD CPE). Fix: patch firmware from Moxa |
What does this mean for affected devices?
NVD carries the ICS-CERT description: "Moxa IKS and EDS does not properly check authority on server side, which results in a read-only user being able to perform arbitrary configuration changes." ICS-CERT, the CNA, classes it CWE-284, improper access control; NVD's own weakness entry is NVD-CWE-Other. The record was published on 2019-03-05 (NVD, CVE record).
What does the flaw let a read-only user do?
The switches have a read-only account role for operators who should only look at status pages. The web interface hides the configuration controls from that role, but the server does not check the role again when a change request arrives, so a read-only login is enough to change the switch configuration. Moxa's advisory MCSA-190201 lists it as item 6, "Improper web interface access control", with the impact that "the authority is not properly checked from the server side, which results in read-only users being able to alter configurations." Any change an administrator can make, such as VLANs, port settings or redundancy, is then open to anyone holding read-only credentials.
How severe is it, and who scored it?
NVD's Primary score is CVSS v3.1 7.5 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N), an integrity impact only, with a CVSS v2 score of 5.0. CISA's ICSA-19-057-01 CSAF file scores CVSS v3.0 9.1 (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H), adding a high availability impact; the summary text in the same file prints the vector with I:N/A:H, so CISA's own advisory is inconsistent. Both vectors use PR:N even though the description needs a read-only login. The CVE record itself carries no CNA score.
Which switches are affected?
| Source | Products and versions for CVE-2019-6520 |
|---|---|
| Moxa MCSA-190201 (V1.2) | IKS-G6824A Series firmware 5.6 or lower (item 6 of the IKS-G6824A table) |
| CISA ICSA-19-057-01 | IKS-G6824A 5.6 and prior; EDS-405A, EDS-408A and EDS-510A 3.8 and prior |
| CVE record and NVD CPE | IKS-G6824A 4.5 and prior; EDS-405A, EDS-408A and EDS-510A 3.8 and prior |
Moxa's advisory lists this flaw only for the IKS-G6824A; its EDS-405A, EDS-408A and EDS-510A table covers five other CVEs. CISA and the CVE record add the three EDS series. Moxa's revision 1.2 of 2019-09-07 added the IKS-G6824A affected firmware version, 5.6 or lower, which the CVE record (4.5 and prior) and NVD's CPE data never picked up.
How do you fix or mitigate it?
Moxa's solution for the IKS-G6824A is a patch firmware that customers request from Moxa Technical Support; CISA's remediation for all four series is the same patch, requested from Moxa Customer Service. Until the patch is in place, treat read-only accounts as administrator accounts: give them only to people you would trust with configuration rights, change shared read-only passwords, and keep the web interface reachable only from a management network. Our Moxa EDS and EDR guide lists every Moxa switch and router CVE with its fix, and the authentication bypass guide covers server-side authorization checks in device web interfaces. Related advisories from the same Moxa and CISA advisories: CVE-2019-6557, the IKS-G6824A web buffer overflows, CVE-2019-6563, the predictable session cookie, and CVE-2019-6524, the missing limit on failed logins.
CVE-2019-6520 is not in the CISA KEV catalog as of 2026-11-23 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.01665, a percentile of 77.3, in the 2026-11-22 dataset (CISA KEV, FIRST EPSS).
Evidence
- NVD (read 2026-11-23): status Modified, published 2019-03-05, last modified 2026-06-17; NVD Primary CVSS v3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N and CVSS v2 5.0; CWE-284 (ICS-CERT), NVD-CWE-Other (NVD); CPEs iks-g6824a_firmware up to and including 4.5, eds-405a/eds-408a/eds-510a_firmware up to and including 3.8. — NVD
- CVE record (checked 2026-11-23): state PUBLISHED, CNA ICS-CERT, published 2019-03-05; affected 'IKS-G6824A series Versions 4.5 and prior, EDS-405A series Version 3.8 and prior, EDS-408A series Version 3.8 and prior, and EDS-510A series Version 3.8 and prior'; CWE-284; no CNA CVSS score. — CVE.org
- CISA CSAF ICSA-19-057-01 Update A (initial 2019-02-26, current 2019-10-24), read 2026-11-23: CVE-2019-6520 CWE-284; CVSS v3.0 9.1 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H (summary text prints AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H); known affected IKS-G6824A 5.6 and prior, EDS-405A/408A/510A 3.8 and prior; remediation: patches from Moxa Customer Service, set EDS web configuration to https only. — CISA CSAF ICSA-19-057-01
- Moxa MCSA-190201 V1.2 (released 2019-02-01, V1.2 2019-09-07, page last updated 2020-12-14), read 2026-11-23: CVE-2019-6520 is item 6 'Improper web interface access control' in the IKS-G6824A table only; IKS-G6824A firmware 5.6 or lower, EDS-405A/408A/510A 3.8 or lower; IKS-G6824A solution: request a patch firmware from Moxa Technical Support; V1.2 added the IKS-G6824 affected firmware version. — Moxa MCSA-190201
- Not in the CISA KEV catalog, version 2026.11.20 (1,790 entries), checked 2026-11-23. — CISA KEV
- EPSS 0.01665, percentile 0.77334, dataset 2026-11-22, read 2026-11-23. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which Moxa switches does CVE-2019-6520 affect?
Moxa's MCSA-190201 lists it for the IKS-G6824A Series on firmware 5.6 or lower. CISA's ICSA-19-057-01 and the CVE record also list the EDS-405A, EDS-408A and EDS-510A Series on firmware 3.8 and prior; the CVE record and NVD give 4.5 and prior for the IKS-G6824A.
How do I fix CVE-2019-6520?
Request the patch firmware from Moxa Technical Support, as MCSA-190201 and CISA's advisory say. Until it is installed, give read-only accounts only to people you would trust with configuration rights and keep the web interface on a management network.
Why does CISA score CVE-2019-6520 at 9.1 and NVD at 7.5?
CISA's CVSS v3.0 vector rates integrity and availability as high. NVD's CVSS v3.1 vector rates integrity only. Both use no required privileges, although the description says the attacker is a read-only user.
Is CVE-2019-6520 exploited in the wild?
It is not in the CISA KEV catalog as of 2026-11-23 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.01665 (percentile 77.3) in the 2026-11-22 dataset.
Questions about this page?