CVE-2017-7920 is an improper authentication flaw in the web server of the ABB VSN300 WiFi Logger Card, the expansion card that puts UNO and TRIO solar string inverters on a network: one URL returns internal status and connected-device information without a login. NVD scores it 7.5 (high). ABB fixed it in card firmware 1.9.0 and React card firmware 2.2.5.
Vulnerability summary
CVSS base score
7.5
High severity
EPSS score (FIRST)
2.7%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2017-7920 · Source: NVD

Affected components
| Component | CPE | Version range |
|---|---|---|
| ABB VSN300 WiFi Logger Card | cpe:2.3:o:abb:vsn300_firmware:*:*:*:*:*:*:*:* | firmware 1.8.15 and earlier; fixed in 1.9.0 or newer (NVD, CISA ICSA-17-192-03) |
| ABB VSN300 WiFi Logger Card for React | cpe:2.3:o:abb:vsn300_for_react_firmware:2.1.3:*:*:*:*:*:*:* | firmware 2.1.3 and earlier (CISA ICSA-17-192-03; the NVD CPE names 2.1.3 only); fixed in 2.2.5 or newer |
What does this mean for affected devices?
What is CVE-2017-7920?
NVD describes CVE-2017-7920 as "an Improper Authentication issue" in "ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating." NVD's Primary score is CVSS v3.0 7.5 (high), vector CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N, with a legacy CVSS v2 score of 5.0 (AV:N/AC:L/Au:N/C:P/I:N/A:N) and CWE-287, Improper Authentication, as its Primary weakness (NVD). The impact is confidentiality only: no integrity or availability effect is scored.
The card itself is an expansion board that sits in the inverter's internal slot. FIMER's VSN300 product page describes it as an "advanced expansion board for UNO and TRIO string inverters" for "monitoring and controlling their photovoltaic system", with Wi-Fi networking, a Modbus TCP server for SCADA integration and data transfer to the Aurora Vision plant management platform. The status data behind the unauthenticated URL therefore describes a live solar installation.
Which VSN300 firmware versions are affected?
CISA published ICSA-17-192-03 on 11 July 2017. Its CISA CSAF advisory lists two products:
- VSN300 WiFi Logger Card, versions 1.8.15 and prior
- VSN300 WiFi Logger Card for React, versions 2.1.3 and prior
CISA assigns the same 7.5 score and vector as NVD and the same CWE-287, so there is no scoring split for this CVE. NVD's configuration matches the first product with cpe:2.3:o:abb:vsn300_firmware up to and including 1.8.15; for the React card it lists only the single version 2.1.3, while CISA covers 2.1.3 and every earlier build. CISA credits Maxim Rupp with identifying the vulnerabilities, and at release it knew of no public exploits that specifically targeted them. ABB's own list of cybersecurity alerts and notifications carries the matching entry "Vulnerability in ABB VSN300 Wi-Fi Logger Card", dated 2017-07-14.
How do I fix CVE-2017-7920?
CISA quotes ABB's remediation: "update firmware to version 1.9.0 or newer for WiFi Logger Card, and version 2.2.5 or newer for WiFi Logger Card for React." The update can be pushed remotely with Aurora Vision or applied through the card's integrated web user interface, which downloads the firmware from the ABB server. Until a card is updated, keep its web server off the internet and off untrusted networks; CISA's recommended practices for the advisory point to its defence-in-depth guidance for control systems.
The same advisory carries a sibling flaw, CVE-2017-7916: the web application "does not properly restrict privileges of the Guest account", so a Guest user may read configuration information that should be restricted (CWE-269, CVSS v3 6.5 in CISA's scoring). The same firmware versions fix both issues.
Why does a logger card matter for solar and DER security?
A logger card is the network edge of an inverter. An unauthenticated status page gives an attacker inventory and plant data without any account, which is the reconnaissance step our NIST SP 1800-32 guide to securing distributed energy resources addresses for DER communication paths. The bug class, a web endpoint that skips the login check, is what our authentication bypass fix guide covers: one central authorisation check for every route, including status and diagnostic URLs. For ABB's other device advisories, see the ABB AC500, RTU500 and Relion guide.
Other solar edge devices on this site show the same pattern of a network card or dongle as the weak point: the Growatt ShineLan-X dongle backdoor account (CVE-2025-36752), the Deye micro-inverter Wi-Fi access-point password (CVE-2023-0808) and the Enphase Envoy gateway command injection (CVE-2023-33869).
Is CVE-2017-7920 exploited?
CVE-2017-7920 is not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25). FIRST EPSS gives it 0.02715, the 87th percentile, in the 2026-11-26 dataset, as of 2026-11-27 (CISA KEV, FIRST EPSS).


Evidence
- Improper authentication in ABB VSN300 WiFi Logger Card 1.8.15 and prior and VSN300 WiFi Logger Card for React 2.1.3 and prior; a specific URL exposes status and connected-device information without authentication; Primary CVSS v3.0 7.5 (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N); Primary CVSS v2 5.0; CWE-287; CPEs vsn300_firmware up to 1.8.15 and vsn300_for_react_firmware 2.1.3. — NVD
- ICSA-17-192-03 released 2017-07-11; affected versions 1.8.15 and prior and 2.1.3 and prior; CVSS v3 7.5, CWE-287; sibling CVE-2017-7916 (CWE-269, 6.5); fix 1.9.0 and 2.2.5 via Aurora Vision or the web user interface; credited to Maxim Rupp; no known public exploits at release. — CISA ICSA-17-192-03 (CSAF)
- ABB lists the advisory "Vulnerability in ABB VSN300 Wi-Fi Logger Card" dated 2017-07-14. — ABB cybersecurity alerts and notifications
- The VSN300 Wifi Logger Card is an expansion board for UNO and TRIO string inverters for monitoring and controlling a photovoltaic system, with a Modbus TCP server and data transfer to Aurora Vision. — FIMER VSN300 product page
- Not in the KEV catalog, version 2026.11.25, checked 2026-11-27. — CISA KEV
- EPSS 0.02715, 87th percentile, 2026-11-26 dataset. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which firmware fixes CVE-2017-7920?
ABB's fix is firmware 1.9.0 or newer for the VSN300 WiFi Logger Card and 2.2.5 or newer for the VSN300 WiFi Logger Card for React. It can be installed remotely through Aurora Vision or from the card's web interface (per CISA ICSA-17-192-03).
What can an attacker get through CVE-2017-7920?
Read access only: a specific URL on the card's web server returns internal status and connected-device information without a login. NVD scores confidentiality impact high and integrity and availability impact none (per NVD).
Is there a related VSN300 vulnerability?
Yes. The same CISA advisory covers CVE-2017-7916, where the Guest account is not properly restricted and may read configuration information that should be protected. CISA scores it 6.5, and the same firmware updates fix it (per CISA ICSA-17-192-03).
Is CVE-2017-7920 in the CISA KEV catalog?
No. It is not listed in catalog version 2026.11.25, checked 2026-11-27, and FIRST EPSS gives it 0.02715, the 87th percentile, in the 2026-11-26 dataset (per CISA KEV and FIRST EPSS).
Questions about this page?