CVE-2017-5163 is a path traversal flaw in the Belden Hirschmann GECKO Lite Managed switch, version 2.0.00 and earlier: after an administrator downloads the configuration, a copy with the users' password hashes can be read without logging in. NVD and CISA score it 5.9. Belden fixed it in GECKO 02.0.01; rebooting after each configuration download is the interim control.
Vulnerability summary
CVSS base score
5.9
Medium severity
EPSS score (FIRST)
1.9%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2017-5163 · Source: NVD
Affected components
| Component | CPE | Version range |
|---|---|---|
| Belden Hirschmann GECKO Lite Managed switch | cpe:2.3:o:belden_hirschmann:gecko_lite_managed_switch_firmware:*:*:*:*:*:*:*:* | 2.0.00 and prior (NVD, CISA ICSA-17-026-02A); fixed in 02.0.01 |
What does this mean for affected devices?
NVD carries the ICS-CERT description: "After an administrator downloads a configuration file, a copy of the configuration file, which includes hashes of user passwords, is saved to a location that is accessible without authentication by path traversal." The product is the Belden Hirschmann GECKO Lite Managed switch, version 2.0.00 and prior. NVD's Primary score is CVSS v3.0 5.9 (CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N), v2 4.3, with CWE-22 (path traversal). ICS-CERT published the record on 2017-02-13 (NVD, CVE record).
What can an attacker get from the GECKO switch?
The leftover file is a full configuration copy with the password hashes of the switch users, and reading it needs no login. The attack has a timing condition, which is why the score carries high attack complexity: the copy exists only after an administrator has downloaded the configuration, and the reboot workaround below removes it. Once an attacker holds the hashes, weak passwords can be cracked offline. CISA scores the flaw the same as NVD, 5.9, and rates it remotely exploitable with a low skill level; it reported no known public exploits that target it (CISA CSAF ICSA-17-026-02A).
Which versions are affected and what fixes it?
CISA lists the Hirschmann GECKO Lite Managed switch at version 2.0.00 and earlier, and NVD's configuration matches the same range. CISA advisory ICSA-17-026-02A says Belden released GECKO software version 02.0.01 to address the identified vulnerabilities and recommends updating to the newest version (CISA CSAF ICSA-17-026-02A). Until the update is in, Belden's interim control is to reboot the switch after each configuration download, which clears the vulnerable state. CISA also points to Belden bulletins BSECV-2016-5 and BSECV-2017-7.
The same CISA advisory covers three more GECKO web flaws fixed by 02.0.01: server-side request forgery (CVE-2017-6036, 6.5), cross-site request forgery (CVE-2017-6038, 7.1) and anonymous information exposure (CVE-2017-6040, 5.3). The Hirschmann and Belden switch vulnerability guide lists the GECKO row with the Classic and HiOS flaws, and later Belden bulletins name newer GECKO releases (2.3.3 for libexpat, 02.4.00 for OpenSSL), so 02.0.01 is a floor, not a target.
How does this compare with similar device flaws?
A configuration file that can be read without logging in is a common pattern in small managed devices. CVE-2016-4495 is the same outcome on a KMC Controls BACnet router, and CVE-2018-19052 is a path traversal in the lighttpd web server used in many embedded images. Our path traversal fix guide covers keeping temporary export files out of the web root and normalising request paths.
CVE-2017-5163 is not in the CISA KEV catalog as of 2026-11-21 (catalog version 2026.11.20, 1,790 entries). FIRST EPSS gives it 0.01901, the 80.2nd percentile, in the 2026-11-20 dataset (CISA KEV, FIRST EPSS).
Evidence
- NVD (read 2026-11-21): status Modified; published 2017-02-13; NVD Primary CVSS v3.0 5.9 CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N, v2 4.3; CWE-22; CPE gecko_lite_managed_switch_firmware up to and including 2.0.00; references ICSA-17-026-02 and BID 95815. — NVD
- CISA ICSA-17-026-02A CSAF (initial 2017-01-26, Update A 2017-04-18), read 2026-11-21: product Hirschmann GECKO Lite Managed switch <= 2.0.00; CVE-2017-5163 CWE-22 CVSS v3.0 5.9 AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N; CVE-2017-6036 CWE-918 6.5 AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N; CVE-2017-6038 CWE-352 7.1 AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:L; CVE-2017-6040 CWE-200 5.3; Belden released version 02.0.01; interim control reboot after each configuration download; Belden bulletins BSECV-2016-5 and BSECV-2017-7 referenced; remotely exploitable, low skill level; no known public exploits specifically target these vulnerabilities. — CISA CSAF ICSA-17-026-02A
- CVE record (checked 2026-11-21): state PUBLISHED, CNA ICS-CERT, published 2017-02-13; problem type Belden Hirschmann GECKO path traversal; no CNA CVSS metric. — CVE.org
- Not in the CISA KEV catalog, version 2026.11.20 (1,790 entries), checked 2026-11-21. — CISA KEV
- EPSS 0.01901, percentile 0.80194, dataset 2026-11-20, read 2026-11-21. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which GECKO firmware fixes CVE-2017-5163?
CISA ICSA-17-026-02A says Belden released version 02.0.01 to fix it and the other GECKO flaws in the advisory. Later Belden bulletins name newer GECKO releases for third-party library fixes, so update to the current release.
What can I do before updating?
Belden's interim control, quoted by CISA, is to reboot the switch after each configuration download, which removes the copy of the configuration file. Keep the web interface reachable only from management hosts.
What does an attacker gain?
A copy of the switch configuration with the user password hashes, without logging in. Weak passwords can then be cracked offline, so change GECKO passwords if the switch ran 2.0.00 or earlier on a shared network.
Is CVE-2017-5163 exploited?
It is not in the CISA KEV catalog as of 2026-11-21 (version 2026.11.20), and CISA reported no known public exploits targeting it. FIRST EPSS gives it 0.01901, the 80.2nd percentile, in the 2026-11-20 dataset.
Questions about this page?