CVE-2016-4501 is an authentication bypass in the Environmental Systems Corporation (ESC) 8832 Data Controller, version 3.02 and earlier, used in the US energy sector. Sessions are handled incorrectly, so a remote attacker can skip the login and change the device configuration. NVD and CISA both score it 9.1. ESC recommends upgrading the device or blocking port 80.
Vulnerability summary
CVSS base score
9.1
Critical severity
EPSS score (FIRST)
1.7%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2016-4501 · Source: NVD

Affected components
| Component | CPE | Version range |
|---|---|---|
| Environmental Systems Corporation ESC 8832 Data Controller | cpe:2.3:a:envirosys:esc_8832_data_controller:*:*:*:*:*:*:*:* | 3.02 and earlier (CISA ICSA-16-147-01B, NVD); ESC recommends upgrading the device, or blocking port 80 and not using the web interface |
What does this mean for affected devices?
The CVE record from CISA says the ESC 8832 Data Controller 3.02 and earlier "mishandles sessions, which allows remote attackers to bypass authentication and make arbitrary configuration changes via unspecified vectors." NVD maps it to CWE-284, improper access control; CISA uses CWE-287, improper authentication (NVD, CVE record).
How severe is CVE-2016-4501?
NVD's Primary score is CVSS v3.0 9.1, CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N, with a CVSS v2 score of 6.4. CISA's score is the same 9.1. Confidentiality and integrity are rated high because an attacker can read and change the controller's configuration; availability is not rated.
What is affected and what fixes it?
CISA's ICSA-16-147-01B, first released on 2016-05-26, covers the ESC 8832 Data Controller, version 3.02 and earlier. CISA describes it as a web-based SCADA system, deployed mainly in the United States energy sector; ESC is based in Austin, Texas. Update B of the advisory added this CVE. ESC's recommendation is to upgrade the device. As alternatives, it suggests blocking port 80 with a firewall in front of the controller, or telling operators not to use the web interface for device management, since the controller can be managed by other means. ESC's own advisory is on its support site behind a login.
The same advisory covers CVE-2016-4502, access to hidden functions by guessing a parameter (7.5). CISA also notes that a public exploit module exists that can hijack a valid session, so treat a reachable web port as an open door. The authentication bypass fix guide covers proper session handling, and the ISO/IEC 27019 guide covers controls for energy utilities. Other authentication bypass pages in energy and facility systems: CVE-2017-7920 (ABB VSN300 logger card) and CVE-2025-41450 (Danfoss AK-SM 800A).
Is CVE-2016-4501 exploited?
CVE-2016-4501 is not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS gives it 0.01728, the 78.01st percentile, in the 2026-11-26 dataset (CISA KEV, FIRST EPSS).


Evidence
- NVD (read 2026-11-27): status Modified; published 2016-05-31; NVD Primary CVSS v3.0 9.1 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N; NVD Primary CVSS v2 6.4; CWE-284; CPE envirosys:esc_8832_data_controller up to and including 3.02. — NVD
- CISA ICSA-16-147-01B CSAF (read 2026-11-27): ESC 8832 <=3.02; CWE-287; CVSS 9.1; ESC recommends upgrading the device, or blocking port 80 with a firewall, or not using the web interface for device management; ESC advisory on its support site (login required); sibling CVE-2016-4502 CWE-284, 7.5. — CISA ICSA-16-147-01B
- CISA advisory page (read 2026-11-27 via a page fetch): original release 2016-05-26, Update B added CVE-2016-4501; web-based SCADA systems; US energy sector; ESC in Austin, Texas; a publicly available Metasploit module can hijack a valid session. — CISA
- CVE record (read 2026-11-27): CNA ICS-CERT; no CNA CVSS in the record. — CVE.org
- Not in the CISA KEV catalog, catalog version 2026.11.25, 1,805 entries, checked 2026-11-27. — CISA KEV
- EPSS 0.01728, percentile 0.78012, dataset 2026-11-26, read 2026-11-27. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Which ESC 8832 versions are affected by CVE-2016-4501?
The ESC 8832 Data Controller, version 3.02 and earlier, per CISA ICSA-16-147-01B and NVD.
How do I mitigate CVE-2016-4501?
ESC recommends upgrading the device. Alternatives are blocking port 80 with a firewall in front of the controller, or managing it by other means than the web interface. CISA adds isolation from the internet and business network.
Is there a public exploit?
CISA's advisory says a public exploit module exists that can hijack a valid session, which makes the web port a real risk on any reachable controller. The CVE is not in the CISA KEV catalog as of 2026-11-27.
What is the EPSS score of CVE-2016-4501?
FIRST EPSS rates it 0.01728 (78.01st percentile) in the 2026-11-26 dataset. It is not in the CISA KEV catalog (catalog version 2026.11.25, 1,805 entries) as of 2026-11-27.
Questions about this page?