Security Advisory

CVE-2016-2293: Acuvim II AXM-NET Unauthenticated Settings

Last updated:
  • CVE-2016-2293

CVE-2016-2293 is a missing authentication flaw in the AXM-NET Ethernet module of Accuenergy Acuvim II and Acuvim IIR power meters, firmware 3.08. A remote attacker can read the meter settings by requesting a page directly, without logging in. NVD and CISA both score it 8.6. Accuenergy published mitigation guidance rather than a named firmware fix.

Vulnerability summary

CVSS base score

8.6

High severity

EPSS score (FIRST)

2.0%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2016-2293 · Source: NVD

CVSS v3.1 severity rating scale: None 0.0, Low 0.1 to 3.9, Medium 4.0 to 6.9, High 7.0 to 8.9, Critical 9.0 to 10.0
How a CVSS v3.1 base score maps to a severity rating. Source: FIRST CVSS v3.1 specification, section 5.

Affected components

ComponentCPEVersion range
Accuenergy Acuvim II power meter with AXM-NET modulecpe:2.3:o:accuenergy:acuvim_ii_net_firmware:*:*:*:*:*:*:*:*Acuvim II NET firmware 3.08 (CISA ICSA-16-105-02); NVD CPE up to and including 3.08; mitigations per Accuenergy guidance, no fixed firmware named by CISA
Accuenergy Acuvim IIR power meter with AXM-NET modulecpe:2.3:o:accuenergy:acuvim_iir_net_firmware:*:*:*:*:*:*:*:*Acuvim IIR NET firmware 3.08 (CISA ICSA-16-105-02); NVD CPE up to and including 3.08

What does this mean for affected devices?

The CVE record from CISA says the AXM-NET module in Accuenergy Acuvim II NET Firmware 3.08 and Acuvim IIR NET Firmware 3.08 "allows remote attackers to discover settings via a direct request to an unspecified URL." NVD files it under CWE-264, permissions and access control; CISA uses CWE-306, missing authentication for a critical function (NVD, CVE record).

How severe is CVE-2016-2293?

NVD's Primary score is CVSS v3.0 8.6, CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L, with a CVSS v2 score of 7.5. CISA's score is the same 8.6. Confidentiality is rated high because the settings pages expose the meter's network and communication setup to anyone who can reach the module.

What is affected and what should operators do?

CISA's ICSA-16-105-02 covers Acuvim II NET and Acuvim IIR NET firmware 3.08. CISA describes the Acuvim II as a multifunction power metering device whose Ethernet module serves a web interface with operational data, used in the energy sector mainly in North America and China; Accuenergy is based in Canada. The researcher was Maxim Rupp. CISA names no fixed firmware. Instead, Accuenergy published a document of recommended mitigations, Protect Modbus TCP/IP Meter From Security Risks, and CISA adds its usual advice: keep the meters off the internet, behind firewalls and apart from the business network, with remote access over a VPN.

The same advisory covers CVE-2016-2294, passwords stored in plaintext in the module (7.5). The authentication bypass fix guide covers how to protect every configuration page, and the Modbus protocol security guide explains why a meter's Modbus TCP and web ports should not be reachable from untrusted networks. Other missing-authentication pages for facility and energy devices: CVE-2023-0052 (SAUTER Nova) and CVE-2016-4501 (ESC 8832 Data Controller).

Is CVE-2016-2293 exploited?

CVE-2016-2293 is not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries), and CISA's advisory noted no known public exploit. FIRST EPSS gives it 0.01994, the 81.33rd percentile, in the 2026-11-26 dataset (CISA KEV, FIRST EPSS).

Three signals on every advisory: CVSS says how severe the flaw is, EPSS gives the probability of exploitation in the wild in the next 30 days, and a CISA KEV listing means the flaw has been exploited in the wild
CVSS rates severity, EPSS estimates the likelihood of exploitation, and CISA KEV records exploitation seen in the wild. Source: FIRST EPSS; CISA KEV catalog.
How to fix this class of issueThis advisory's weakness class is Authentication bypass. Our practical guide covers how to detect, fix, verify and disclose it: How to fix authentication bypass in embedded firmware.
From advisory to verified fix in four steps: read the advisory, find the affected component in the firmware SBOM, apply the fixed version or vendor mitigation, then re-scan the image to confirm the vulnerable version is gone
Read the advisory, find the component in your firmware SBOM, apply the fix, then re-scan to confirm it.

Evidence

  • NVD (read 2026-11-27): status Modified; published 2016-04-21; NVD Primary CVSS v3.0 8.6 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L; NVD Primary CVSS v2 7.5; CWE-264; CPEs accuenergy:acuvim_ii_net_firmware and acuvim_iir_net_firmware up to and including 3.08. — NVD
  • CISA ICSA-16-105-02 CSAF (read 2026-11-27): Acuvim II NET and Acuvim IIR NET firmware 3.08; CWE-306; CVSS 8.6; Accuenergy document with recommended mitigations; sibling CVE-2016-2294 CWE-256, 7.5. — CISA ICSA-16-105-02
  • CISA advisory page (read 2026-11-27 via a page fetch): multifunction power metering device with Ethernet module web interface; energy sector; mainly North America and China; HQ Canada; researcher Maxim Rupp; no fixed firmware specified; no known public exploits. — CISA
  • Accuenergy article 'Protect Modbus TCP/IP Meter From Security Risks', the mitigation document CISA links (page title read 2026-11-27). — Accuenergy
  • CVE record (read 2026-11-27): CNA ICS-CERT; no CNA CVSS in the record. — CVE.org
  • Not in the CISA KEV catalog, catalog version 2026.11.25, 1,805 entries, checked 2026-11-27. — CISA KEV
  • EPSS 0.01994, percentile 0.81327, dataset 2026-11-26, read 2026-11-27. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CISA ICSA-16-105-02: Accuenergy Acuvim II Series AXM-NET Module Vulnerabilities (CSAF)
  3. CISA ICSA-16-105-02 advisory page
  4. Accuenergy: Protect Modbus TCP/IP Meter From Security Risks
  5. CVE.org record CVE-2016-2293
  6. CISA KEV
  7. FIRST EPSS

Frequently asked questions

Which Acuvim firmware is affected by CVE-2016-2293?

Acuvim II NET and Acuvim IIR NET firmware 3.08 on the AXM-NET Ethernet module (CISA ICSA-16-105-02). NVD's CPE range reads up to and including 3.08.

Is there a firmware fix?

CISA's advisory names no fixed firmware. Accuenergy published recommended mitigations in its article on protecting Modbus TCP/IP meters, and CISA advises keeping the meters off the internet and behind firewalls.

What does an attacker gain?

Per the CVE record, a remote attacker can read the meter's settings without logging in. The sibling CVE-2016-2294 covers plaintext password storage in the same module.

Is CVE-2016-2293 in the CISA KEV catalog?

No, not as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS rates it 0.01994 (81.33rd percentile) in the 2026-11-26 dataset.