CVE-2015-3964 is a set of hard-coded passwords in the SMA Solar Technology Sunny WebBox, a monitoring unit for photovoltaic plants, which make it easier for a remote attacker to log in. NVD scores it 10.0 (CVSS v2). CISA names no fixed firmware version; SMA recommends turning off port forwarding and using a VPN for remote access instead.
Vulnerability summary
CVSS base score
10
Critical severity
EPSS score (FIRST)
3.4%
Probability of exploitation in the wild in the next 30 days
CISA KEV catalog
No
Not listed
Published
Vulnerability ID: CVE-2015-3964 · Source: NVD

Affected components
| Component | CPE | Version range |
|---|---|---|
| SMA Solar Technology Sunny WebBox (PV plant monitoring) firmware | cpe:2.3:o:sma_solar_technology_ag:webbox_firmware:-:*:*:*:*:*:*:* | CISA ICSA-15-181-02A: all versions; NVD CPE webbox_firmware without a version; mitigation: no port forwarding, VPN for remote access, SMA recommendations via Sunny Portal |
What does this mean for affected devices?
NVD's description reads: "SMA Solar Sunny WebBox has hardcoded passwords, which makes it easier for remote attackers to obtain access via unspecified vectors." NVD's Primary score is CVSS v2 10.0 (AV:N/AC:L/Au:N/C:C/I:C/A:C) with NVD-CWE-Other; there is no NVD v3 score. ICS-CERT assigned the record with vendor and product n/a and no CNA score; it was published on 2015-09-11 (NVD, CVE record).
Who found it, and what does CISA say?
CISA's advisory ICSA-15-181-02A (CSAF), "SMA Solar Technology AG Sunny WebBox Hard-Coded Account Vulnerability", maps the flaw to CWE-798, use of hard-coded credentials, gives the same CVSS v2 10.0 and lists all Sunny WebBox versions as affected. The researcher post on the Full Disclosure list describes the WebBox as a "monitoring solution for medium-sized PV plants" and says the account was presented at the 31C3 conference by Alexander Timorin. The SCADA StrangeLove group's follow-up post of September 2015 says the issue "is fixed" and that Shodan then counted about 9,500 WebBoxes online, against about 80,000 in December 2014.
How do I protect a Sunny WebBox?
CISA's remediation does not name a fixed firmware version. It says SMA sent security recommendations to WebBox users through its Sunny Portal platform and "expressly recommends deactivation of port-forwarding or use of a VPN to access these devices remotely"; owners can get details from Sunny Portal or SMA customer service. In practice: remove any router port forwarding to the WebBox, reach it only over a VPN or the plant LAN, and check that the unit runs the newest firmware SMA offers for it. CISA's general practices apply as well: no internet exposure for control devices, firewalls between plant and office networks.
The hard-coded credentials fix guide covers how vendors remove built-in accounts, and the NIST SP 1800-32 guide covers securing distributed energy resources such as PV plants. CVE-2015-7930 is a similar built-in credential in a telemetry base station.
CVE-2015-3964 is not in the CISA KEV catalog as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS gives it 0.0339, a percentile of 89.6, in the 2026-11-26 dataset (CISA KEV, FIRST EPSS).


Evidence
- NVD (read 2026-11-27): status Modified; published 2015-09-11; NVD Primary CVSS v2 10.0 AV:N/AC:L/Au:N/C:C/I:C/A:C; no v3 metric; CWE NVD-CWE-Other; CPE sma_solar_technology_ag webbox_firmware '-'; references ICSA-15-181-02 and Full Disclosure 2015/Sep/51. — NVD
- CISA ICSA-15-181-02A CSAF (read 2026-11-27): CVE-2015-3964 CWE-798, CVSS v2 10.0 AV:N/AC:L/Au:N/C:C/I:C/A:C; Sunny WebBox all versions; remediation: SMA has sent out security recommendations via its Sunny Portal Online Platform to WebBox users and expressly recommends deactivation of port-forwarding or use of a VPN to access these devices remotely. — CISA ICSA-15-181-02A
- Full Disclosure post (2015-09): CVE-2015-3964 Sunny WebBox (monitoring solution for medium-sized PV plants) hard-coded account vulnerability is fixed; presented at 31C3 by Alexander Timorin. — Full Disclosure
- SCADA StrangeLove blog, September 2015: Sunny WebBox hard-coded account is fixed; about 9,500 online per Shodan vs 80,000 in December 2014. — SCADA StrangeLove
- CVE record (checked 2026-11-27): state PUBLISHED, CNA icscert; published 2015-09-11, affected n/a / n/a; no CNA CVSS. — CVE.org
- Not in the CISA KEV catalog, catalog version 2026.11.25, 1,805 entries, checked 2026-11-27. — CISA KEV
- EPSS 0.03388, percentile 0.89578, dataset 2026-11-26, read 2026-11-27. — FIRST EPSS

Related advisories
Sources
Frequently asked questions
Is there a firmware version that fixes CVE-2015-3964?
CISA's advisory names none. The researchers wrote in September 2015 that the issue is fixed, and SMA sent recommendations to WebBox users through Sunny Portal. Check with SMA for the newest firmware available for your unit.
What does SMA recommend?
According to CISA, SMA expressly recommends deactivating port forwarding to the WebBox or using a VPN to reach it remotely. Details are on the Sunny Portal platform or from SMA customer service.
Why does internet exposure matter so much here?
A hard-coded password is the same on every unit, so anyone who knows it can try it against any reachable WebBox. The researchers counted about 80,000 WebBoxes online in December 2014 and about 9,500 in September 2015.
Is CVE-2015-3964 in the CISA KEV catalog?
No, not as of 2026-11-27 (catalog version 2026.11.25, 1,805 entries). FIRST EPSS rates it 0.0339 (percentile 89.6) in the 2026-11-26 dataset.
Questions about this page?