Security Advisory

CVE-2012-1801: ABB WebWare and RobotStudio COM Overflows

Last updated:
  • CVE-2012-1801

CVE-2012-1801 covers stack-based buffer overflows in COM and ActiveX controls installed with legacy ABB robotics PC software: WebWare Server and SDK, Interlink Module, S4 OPC Server, QuickTeach, RobotStudio S4 and RobotStudio Lite. Crafted input to the controls can crash them or run code. NVD scores it 7.7 (CVSS v2). ABB issues no patch and points to hardening guidance.

Vulnerability summary

CVSS base score

7.7

High severity

EPSS score (FIRST)

1.6%

Probability of exploitation in the wild in the next 30 days

CISA KEV catalog

No

Not listed

Published

Vulnerability ID: CVE-2012-1801 · Source: NVD

CVSS v3.1 severity rating scale: None 0.0, Low 0.1 to 3.9, Medium 4.0 to 6.9, High 7.0 to 8.9, Critical 9.0 to 10.0
How a CVSS v3.1 base score maps to a severity rating. Source: FIRST CVSS v3.1 specification, section 5.

Affected components

ComponentCPEVersion range
ABB WebWare Server (Data Collector, Interlink) and WebWare SDKcpe:2.3:a:abb:webware_server:-:*:*:*:*:*:*:*ABB SI10231A2 and CISA ICSA-12-095-01A: all versions; legacy, no patch
ABB Interlink Module, S4 OPC Server, QuickTeach, RobotStudio S4, RobotStudio Litecpe:2.3:a:abb:s4_opc_server:-:*:*:*:*:*:*:*ABB SI10231A2 and CISA ICSA-12-095-01A: all versions; legacy, no patch

What does this mean for affected devices?

NVD's description reads: "Multiple stack-based buffer overflows in (1) COM and (2) ActiveX controls in ABB WebWare Server, WebWare SDK, Interlink Module, S4 OPC Server, QuickTeach, RobotStudio S4, and RobotStudio Lite allow remote attackers to execute arbitrary code via crafted input data." NVD's Primary score is CVSS v2 7.7 (AV:A/AC:L/Au:S/C:C/I:C/A:C) with CWE-119; there is no NVD v3 score. NVD's CPE data lists the seven products without version limits. CERT/CC assigned the record with vendor and product n/a and no CNA score; NVD published it on 2012-04-18 (NVD, CVE record).

What does ABB say?

ABB's advisory SI10231A2 (ABB-VU-DMRO-41532, revision 1.0, 2012-03-23) gives an overall score of 7.7 and lists all versions of each product. The controls talk to the robot controller or the WebWare Server, provide HMI elements, or support training and robot-cell programming; they do not fully check input data, and the ActiveX controls are registered as scriptable. ABB describes three outcomes: denial of service, privilege escalation to the level of the service (Administrator in some installations) on machines with a developer license, and code execution in the browser if a user visits a malicious web page. ABB credits Billy Rios, Terry McCorkle and the ICS-CERT team, who first reported it in WebWare Server 4.91.

CISA's advisory 12-095-01A (CSAF), "ABB Multiple Components Buffer Overflow", lists the same products, all versions, with CVSS v2 7.7 and CWE-119.

How do I fix it?

There is no patch. ABB calls the products legacy PC tools nearing end of life that are no longer actively developed, and directs users to its "WebWare Component Security" paper (SI10231A1) and to general cyber security practice. In practice that means replacing them with current ABB robot software, removing the tools from PCs that no longer need them, keeping the remaining PCs off the internet and email, and isolating the robot cell network. Contact the local ABB Robotics service organization for migration help.

CVE-2012-0245 is a buffer overflow in ABB Robot Communications Runtime from the same period. The memory corruption guide explains stack overflows, and the OT/ICS security guide for small manufacturers covers retiring unsupported engineering tools.

CVE-2012-1801 is not in the CISA KEV catalog as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS gives it 0.0155, a percentile of 75.5, in the 2026-11-27 dataset (CISA KEV, FIRST EPSS).

Three signals on every advisory: CVSS says how severe the flaw is, EPSS gives the probability of exploitation in the wild in the next 30 days, and a CISA KEV listing means the flaw has been exploited in the wild
CVSS rates severity, EPSS estimates the likelihood of exploitation, and CISA KEV records exploitation seen in the wild. Source: FIRST EPSS; CISA KEV catalog.
How to fix this class of issueThis advisory's weakness class is Memory corruption. Our practical guide covers how to detect, fix, verify and disclose it: How to fix memory corruption in embedded firmware.
From advisory to verified fix in four steps: read the advisory, find the affected component in the firmware SBOM, apply the fixed version or vendor mitigation, then re-scan the image to confirm the vulnerable version is gone
Read the advisory, find the component in your firmware SBOM, apply the fix, then re-scan to confirm it.

Evidence

  • NVD (read 2026-11-28): status Modified; published 2012-04-18; NVD Primary CVSS v2 7.7 AV:A/AC:L/Au:S/C:C/I:C/A:C; no v3 metric; CWE-119; CPEs abb interlink_module, quickteach, robotstudio_lite, robotstudio_s4, s4_opc_server, webware_sdk, webware_server (no versions). — NVD
  • CISA ICSA-12-095-01A CSAF (read 2026-11-28): WebWare Server (Data Collector, Interlink), WebWare SDK, Interlink Module, S4 OPC Server, QuickTeach, RobotStudio S4, RobotStudio Lite, all versions; CVE-2012-1801 CWE-119, CVSS v2 7.7 AV:A/AC:L/Au:S/C:C/I:C/A:C; legacy products, ABB does not intend to patch; customer advisory and WebWare Component Security whitepaper; contact local ABB Robotics service. — CISA ICSA-12-095-01A
  • CVE record (read 2026-11-28): state PUBLISHED, assigner certcc, vendor and product n/a, no CNA CVSS. — CVE.org
  • ABB SI10231A2 rev 1.0 (ABB-VU-DMRO-41532, last edit 2012-03-23, read 2026-11-28): overall CVSS 7.7; all versions of the seven products; COM/ActiveX controls lack complete input checks, ActiveX registered as scriptable; DoS, privilege escalation on developer-license machines (Administrator in some installations), browser code execution via malicious web page; legacy, no longer actively developed; mitigation per SI10231A1 WebWare Component Security; credit Billy Rios, Terry McCorkle and ICS-CERT, first reported in WebWare Server 4.91. — ABB
  • Not in the CISA KEV catalog, catalog version 2026.11.27, 1,808 entries, checked 2026-11-28. — CISA KEV
  • EPSS 0.01555, percentile 0.75509, dataset 2026-11-27, read 2026-11-28. — FIRST EPSS

Related advisories

Sources

  1. NVD
  2. CISA ICSA-12-095-01A: ABB Multiple Components Buffer Overflow
  3. CISA ICSA-12-095-01A CSAF (machine-readable advisory)
  4. ABB SI10231A2: Advisory for WebWare Components and Related Products
  5. CVE record CVE-2012-1801 (CVE Services JSON)
  6. CISA KEV
  7. FIRST EPSS

Frequently asked questions

Which ABB products are affected?

All versions of WebWare Server (Data Collector and Interlink), WebWare SDK, ABB Interlink Module, S4 OPC Server, QuickTeach, RobotStudio S4 and RobotStudio Lite, according to ABB SI10231A2 and CISA ICSA-12-095-01A.

Is there a patch for CVE-2012-1801?

No. ABB classifies the products as legacy tools that are no longer actively developed and points users to its WebWare Component Security guidance (SI10231A1) instead of a fix.

How can the flaw be exploited?

ABB names two paths: someone with access to the PC calls the COM interfaces with bad input, or a user visits a malicious web page that scripts the ActiveX controls. Keeping the PCs off the internet and email limits both.

Is CVE-2012-1801 in the CISA KEV catalog?

No, not as of 2026-11-28 (catalog version 2026.11.27, 1,808 entries). FIRST EPSS rates it 0.0155 (percentile 75.5) in the 2026-11-27 dataset.